UNE-EN 60137:2011
Withdrawn
Withdrawn
Insulated bushings for alternating voltages above 1 000 V
Available format(s)
Hardcopy , PDF
Language(s)
Spanish, Castilian, English
Published date
01-19-2011
Publisher
Withdrawn date
11-18-2020
US$148.97
Excluding Tax where applicable
| Committee |
CTN 207/SC 36
|
| DevelopmentNote |
Supersedes UNE 21113. (08/2003)
|
| DocumentType |
Standard
|
| Pages |
66
|
| PublisherName |
Asociación Española de Normalización
|
| Status |
Withdrawn
|
| Standards | Relationship |
| NBN EN 60137 : 2010 | Identical |
| I.S. EN 60137:2008 | Identical |
| BS EN 60137:2008 | Identical |
| IEC 60137:2008 | Identical |
| IEC 60137:2017 | Identical |
| EN 60137:2008 | Identical |
| IEC GUIDE 109:2012 | Environmental aspects - Inclusion in electrotechnical product standards |
| IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
| IEC 60038:2009 | IEC standard voltages |
| IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
| IEC 60076-7:2005 | Power transformers - Part 7: Loading guide for oil-immersed power transformers |
| EN 60376:2005 | Specification of technical grade sulfur hexafluoride (SF6) for use in electrical equipment |
| IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
| EN 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
| IEC 60050-471:2007 | International Electrotechnical Vocabulary (IEV) - Part 471: Insulators |
| EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
| IEC 62217:2012 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
| EN 60076-5:2006 | Power transformers - Part 5: Ability to withstand short-circuit |
| IEC 60050-212:2010 | International Electrotechnical Vocabulary (IEV) - Part 212: Electrical insulating solids, liquids and gases |
| EN 60480:2004 | Guidelines for the checking and treatment of sulphur hexafluoride (SF6) taken from electrical equipment and specification for its re-use |
| IEC 60076-5:2006 | Power transformers - Part 5: Ability to withstand short circuit |
| EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
| IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
| IEC 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
| HD 588.1 : S1 AMD 1 | HIGH VOLTAGE TEST TECHNIQUES - GENERAL DEFINITIONS AND TEST REQUIREMENTS |
| HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
| EN 60270:2001/A1:2016 | HIGH-VOLTAGE TEST TECHNIQUES - PARTIAL DISCHARGE MEASUREMENTS (IEC 60270:2000/A1:2015) |
| IEC 60505:2011 | Evaluation and qualification of electrical insulation systems |
| EN 60216-2:2005 | Electrical insulating materials - Thermal endurance properties - Part 2: Determination of thermal endurance properties of electrical insulating materials - Choice of test criteria |
| IEC 60517:1990 | Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above |
| IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
| IEC 60836:2015 | Specifications for unused silicone insulating liquids for electrotechnical purposes |
| IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
| IEC 60076-3:2013 | Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air |
| IEC 60050-421:1990 | International Electrotechnical Vocabulary (IEV) - Part 421: Power transformers and reactors |
| IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
| EN 60068-2-17:1994 | Environmental testing - Part 2: Tests - Test Q: Sealing |
| IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
| IEC 60076-1:2011 | Power transformers - Part 1: General |
| IEC 62271-203:2011 | High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV |
| IEC TR 60943:1998+AMD1:2008 CSV | Guidance concerning the permissible temperature rise for parts of electrical equipment, in particular for terminals |
| IEC GUIDE 111:2004 | Electrical high-voltage equipment in high-voltage substations - Common recommendations for product standards |
| EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
| IEC 60867:1993 | Insulating liquids - Specifications for unused liquids based on synthetic aromatic hydrocarbons |
| IEC 62271-1:2017 | High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear |
| IEC 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
| EN 60059:1999/A1:2009 | |
| IEC 60059:1999+AMD1:2009 CSV | IEC standard current ratings |
| IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
| IEC 60507:2013 | Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems |
| IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
| EN 60505:2011/AC:2017-03 | EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017) |
| EN 62217:2013 | Polymeric HV insulators for indoor and outdoor use - General definitions, test methods and acceptance criteria |
| IEC TS 61463:2016 | Bushings - Seismic qualification |
Summarise
US$148.97
Excluding Tax where applicable