EN 12015:2014
|
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
|
EN 12016:2013
|
Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
|
EN 50214:2006/corrigendum Dec. 2007
|
FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
|
HD 21-3 : S3 AMD 2 2008
|
POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - NON-SHEATHED CABLES FOR FIXED WIRING
|
HD 215 : 200S1
|
SAFETY REQUIREMENTS FOR INDICATING AND RECORDING ELECTRICAL MEASURING INSTRUMENTS AND THEIR ACCESSORIES
|
HD 214 : 200S2
|
RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
|
HD 384.4.41 S2:1996/A1:2002
|
ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK
|
IEC 60364-4-41:2005+AMD1:2017 CSV
|
Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
|
EN 60249-2-3 : 1994 AMD 4 2000
|
BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 3: EPOXIDE CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST)
|
EN 60950:2000/corrigendum:2002
|
SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
|
HD 384.6.61 : 200S2
|
ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION
|
EN 1050 : 1996
|
SAFETY OF MACHINERY - PRINCIPLES FOR RISK ASSESSMENT
|
EN 81-1:1998+A3:2009
|
Safety rules for the construction and installation of lifts - Part 1: Electric lifts
|
EN ISO 13857:2008
|
Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs (ISO 13857:2008)
|
IEC 60747-5:1992
|
Semiconductor devices - Discrete devices and integrated circuits -Part 5: Optoelectronic devices
|
DIN VDE 0100-540 : 2012-06
|
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS (IEC 60364-5-54:2011)
|
EN 60742:1995
|
Isolating transformers and safety isolating transformers - Requirements
|
IEC 60227-1:2007
|
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
|
HD 22-4 : 200S4
|
CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 4: CORDS AND FLEXIBLE CABLES
|
EN 60249-2-2 : 1994 AMD 5 2000
|
BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 2: PHENOLIC CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET, ECONOMIC QUALITY
|
HD 21.1 : 200S4
|
CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS
|
EN 60068-2-27:2009
|
Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
|
IEC 60364-6:2016
|
Low voltage electrical installations - Part 6: Verification
|
DIN VDE 0282-807 : 1994
|
RUBBER INSULATED CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION - RUBBER INSULATED LIFT CABLES 05RT AND 05RN
|
DIN VDE 0281-5 : 2002
|
POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - FLEXIBLE CABLES (CORDS)
|
EN 60947-4-1 : 2010 AMD 1 2012
|
LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
|
HD 360 : S2 AMD 1
|
CIRCULAR RUBBER INSULATED LIFT CABLES FOR NORMAL USE
|
EN 81-2 : 1998 + A3 2009
|
SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
|
ISO 13857:2008
|
Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs
|
HD 384.5.54 : 200S1
|
ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
|
ISO 1219-1:2012
|
Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications
|
EN 60068-2-29:1993
|
Environmental testing - Part 2: Tests - Test Eb and guidance: Bump
|
EN 60068-2-6:2008
|
Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
|
DIN VDE 0100-600 : 2017-06
|
LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 6: VERIFICATION (IEC 60364-6:2016)
|
DIN VDE 0282-808 : 1994
|
RUBBER INSULATED CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION - RUBBER INSULATED LIFT CABLES 07RT AND 07RN
|
EN 62326-1:2002
|
Printed boards - Part 1: Generic specification
|
IEC 60664-1:2007
|
Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
|
EN 131-1:2015
|
Ladders - Part 1: Terms, types, functional sizes
|
DIN VDE 0281-3 : 2001 AMD 2 2009
|
POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
|
HD 21 PT4 : 200S2
|
POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 4: SHEATHED CABLES FOR FIXED WIRING
|
IEC 60227-5:2011
|
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables (cords)
|
DIN VDE 0281-1 : 2003
|
CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
|