AS/NZS 61558.2.6:2001
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Safety of power transformers, power supply units and similar Particular requirements for safety isolating transformers for general use (IEC 61558-2-6:1997, MOD)
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
25-06-2021
11-06-2001
Specifies safety requirements for approval and test purposes for safety isolating transformers. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-6:1997.
Replacement:This part 2 of IEC 61558 applies to stationary or portable, single-phase or polyphase, air-cooled safety isolating transformers, associated or otherwise, having a rated supply voltage not exceeding 1000 V a.c. and rated frequency not exceeding 500 Hz, the rated output not exceeding:– 10 kVA for single-phase transformers;– 16 kVA for polyphase transformers.This standard is also applicable to safety isolating transformers without limitation of the rated output; however such transformers are considered as special transformers and are subjected to an agreement between the purchaser and the supplier.The no-load output voltage and the rated output voltage does not exceed:50 V a.c. r.m.s. and/or 120 V ripple-free d.c.between conductors or between any conductor and earth.This standard is applicable to dry type transformers. The windings may be encapsulated or non-encapsulated.
Committee |
EL-002
|
DocumentType |
Standard
|
ISBN |
0 7337 4073 1
|
Pages |
10
|
PublisherName |
Standards Australia
|
Status |
Superseded
|
SupersededBy | |
Supersedes | |
UnderRevision |
AS 3108 first published in Australia in part as AS C126-1939.Second edition 1958.AS C167 first published 1962.Revised and redesignated AS 3167-1981 (withdrawn 1987).AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989).AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984.Revised, amalgamated and redesignated AS 3108-1990.First published in New Zealand as NZS/AS 3108:1990.Jointly revised and designated as Joint Standard AS/NZS 3108:1994.Jointly revised and redesignated in part as AS/NZS 61558.2.6:2001. AS 3108 first published in Australia in part as AS C126-1939. Second edition 1958. AS C167 first published 1962. Revised and redesignated AS 3167-1981 (withdrawn 1987). AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989). AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984. Revised, amalgamated and redesignated AS 3108-1990. First published in New Zealand as NZS/AS 3108:1990. Jointly revised and designated as Joint Standard AS/NZS 3108:1994. Jointly revised and redesignated in part as AS/NZS 61558.2.6:2001.
AS/NZS 3112:2000 | Approval and test specification - Plugs and socket-outlets |
AS 1621.3.1-1988 | Pressure-sensitive adhesive electrical tapes Plasticized polyvinyl chloride tapes with non-thermosetting adhesive |
AS 1621.3.3-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with non-thermosetting adhesive |
AS 1621.3.2-1988 | Pressure-sensitive adhesive electrical tapes Polyester film tapes (PETP) with thermosetting adhesive |
AS 2768-1985 | Electrical insulating materials - Evaluation and classification based on thermal endurance |
AS/NZS 3250:1995 | Approval and test specification - Mains operated electronic and related equipment for household and similar general use |
AS 2752-1985 | Preferred numbers and their use |
AS 1621.2-1988 | Pressure-sensitive adhesive electrical tapes Methods of test |
AS/NZS 3947.7.1:2001 | Low-voltage switchgear and controlgear Ancillary equipment - Terminal blocks for copper conductors |
AS/NZS 3191:1996 | Approval and test specification - Electric flexible cords |
AS/NZS 4898:1997 | Approval and test specification - Circuit-breakers for overcurrent protection for household and similar installations |
AS 2005.21.1-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Standardized fuse systems - Fuses with fuse-links with blade contacts |
AS 2005.20-1990 | Low voltage fuses - Fuses with enclosed fuse-links Supplementary requirements for fuses for use by authorized persons (Fuses mainly for industrial application) - Common requirements |
AS 3109.1-1987 | Approval and test specification - Appliance couplers for household and similar general purposes - General requirements |
AS/NZS 3000:2000 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS 1104-1978 | Informative symbols for use on electrical and electronic equipment |
AS/NZS 60998.1:1998 | Connecting devices for low voltage circuits for household and similar purposes General requirements |
AS/NZS 4695.707:1996 | Fire hazard testing of electrotechnical products Methods of test for the determination of the flammability of solid electrical insulating materials when exposed to an igniting source |
AS/NZS 4695.2.11:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire end-product test and guidance |
AS 2374.1-1997 | Power transformers General |
AS/NZS 60998.2.2:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screwless-type clamping units |
AS/NZS 4695.2.10:1996 | Fire hazard testing of electrotechnical products Test methods - Glow-wire test methods - General |
AS 1621.1-1988 | Pressure-sensitive adhesive electrical tapes - General requirements |
AS/NZS 60998.2.1:1998 | Connecting devices for low voltage circuits for household and similar purposes Particular requirements for connecting devices as separate entities with screw-type clamping units |
AS/NZS 3139.1:1995 | Approval and test specification - Switches for appliances General requirements |
AS 1939-1990 | Degrees of protection provided by enclosures for electrical equipment (IP Code) |
AS 1621.3.5-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes with thermosetting adhesive |
AS 1621.3.4-1988 | Pressure-sensitive adhesive electrical tapes Cellulosic paper tapes, creped, with thermosetting adhesive |
AS/NZS 4695.112:1996 | Fire hazard testing of electrotechnical products Method for determining the comparative and the proof tracking indices of solid insulating materials under moist conditions |
AS 2005.30-1991 | Low voltage fuses - Fuses with enclosed fuse-links - Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household and similar applications) |
AS 2703-2008 | Vehicle loop detector sensors |
AS 2865-2009 | Confined spaces |
AS/NZS 3439.4:2009 | Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS) |
AS/NZS 3197:2005 | Approval and test specification - Portable electrical control or conditioning devices |
AS/NZS 3004.2:2008 | Electrical installations - Marinas and recreational boats Recreational boats installations |
AS/NZS 60598.2.22:2005 | Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD) |
AS/NZS 4879.1:2008 | Performance of transformers and electronic step-down convertors for ELV lamps Test method - Energy performance (Reconfirmed 2017) |
AS/NZS 3000:2007 | Electrical installations (known as the Australian/New Zealand Wiring Rules) |
AS/NZS 3136:2001 | Approval and test specification - Electrical equipment for spa and swimming pools |
AS/NZS 3004.1:2008 | Electrical installations - Marinas and recreational boats Marinas |
AS 3533.2-2009 | Amusement rides and devices Operation and maintenance |
AS 3533.1-2009 | Amusement rides and devices Design and construction |
AS/NZS 3100:2002 | Approval and test specification - General requirements for electrical equipment |
AS/NZS 3100:2009 | Approval and test specification - General requirements for electrical equipment |
AS 2832.3-2005 | Cathodic protection of metals Fixed immersed structures |
AS 2832.5-2008 | Cathodic protection of metals Steel in concrete structures |
AS/NZS 3350.1:2002 | Safety of household and similar electrical appliances General requirements (IEC 60335-1:1991, MOD) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.