BS EN 50122-1 : 2011
Current
The latest, up-to-date edition.
RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 1: PROTECTIVE PROVISIONS AGAINST ELECTRIC SHOCK
Hardcopy , PDF
English
01-01-2011
1 Scope
2 Normative references
3 Terms and definitions
4 Contact line zone and current collector zone
5 Protective provisions against direct contact
6 Protective provisions against indirect contact
and impermissible rail potential
7 Protective provisions for low voltage non
traction power supplies
8 Protective provisions where track systems,
which are utilized for carrying traction return
current, or/and contact line systems pass
through hazardous zones
9 Limits for touch voltage and protection against
the danger of rail potential
10 Additional protective provisions
Annex A (informative) - Typical obstacles
Annex B (normative) - Warning sign
Annex C (informative) - Guiding values for rail
potential gradient
Annex D (informative) - Effective touch voltage
and body voltage with respect to the body
current
Annex E (normative) - Measurement methods for
effective touch voltages
Annex F (normative) - The use of voltage-limiting devices
Annex G (normative) - Special national conditions
Bibliography
Annex ZZ (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 2008/57/EC
Defines requirements for the protective provisions relating to electrical safety in fixed installations associated with a.c. and/or d.c. traction systems and to any installations that can be endangered by the traction power supply system.
Committee |
GEL/9/3
|
DevelopmentNote |
Supersedes 94/200413 DC. (09/2005) Supersedes 08/30160532 DC. (06/2011) Supersedes 15/30327969 DC. (02/2016) 2011 Edition Re-Issued in February 2017 & incorporates AMD 4 2017. (03/2017)
|
DocumentType |
Standard
|
Pages |
88
|
PublisherName |
British Standards Institution
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NBN EN 50122-1 : 2011 AMD 2 2016 | Identical |
I.S. EN 50122-1:2011 | Identical |
SN EN 50122-1 : 2011 AMD 4 2017 | Identical |
EN 50122-1:2011/A4:2017 | Identical |
DIN EN 50122-1 : 2017 | Identical |
NEN EN 50122-1 : 2011 AMD 4 2017 | Identical |
UNE-EN 50122-1:2011 | Identical |
NF EN 50122-1 : 2011 AMD 4 2018 | Identical |
BS 7430(2011) : 2011 | CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
ENA ER G12 : ISSUE 4 AMD 1 2015 | REQUIREMENTS FOR THE APPLICATION OF PROTECTIVE MULTIPLE EARTHING TO LOW VOLTAGE NETWORKS |
11/30249994 DC : DRAFT JULY 2011 | BS 7430 - CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
RSSB RIS-1855-ENE : ISSUE 1 | LOW VOLTAGE POWER SUPPLIES IN ELECTRIFIED AREAS |
RSSB GK/RT0053 : ISSUE 1 | CONTROL OF UNWANTED VOLTAGES ON TELECOMMUNICATIONS EQUIPMENT AT STATIONS |
07/30130630 DC : 0 | BS 7430 - CODE OF PRACTICE FOR EARTHING |
RSSB GK/GN0653 : ISSUE 1 | GUIDANCE ON CONTROL OF UNWANTED VOLTAGES ON TELECOMMUNICATIONS EQUIPMENT AT STATIONS |
RSSB GK/GN0622 : ISSUE 1 | GUIDANCE ON IMMUNISATION OF SIGNALLING AND TELECOMMUNICATIONS SYSTEMS AGAINST ELECTRICAL INTERFERENCE FROM 50 HZ SINGLE PHASE A.C. ELECTRIFICATION |
RSSB GL/RT1255 : ISSUE 1 | LOW VOLTAGE POWER SUPPLIES IN ELECTRIFIED AREAS |
IEC 61219:1993 | Live working - Earthing or earthing and short-circuiting equipment using lances as a short-circuiting device - Lance earthing |
ISO 7010:2011 | Graphical symbols Safety colours and safety signs Registered safety signs |
IEC TS 60479-1:2005+AMD1:2016 CSV | Effects of current on human beings and livestock - Part 1: Generalaspects |
IEC 60050-811:1991 | International Electrotechnical Vocabulary (IEV) - Part 811: Electric traction |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
EN 61219:1993 | Live working - Earthing or earthing and short-circuiting equipment using lances as short-circuiting device - Lance earthing |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
HD 60364-4-41:2017/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK |
EN 50153 : 2014 AMD 1 2017 | RAILWAY APPLICATIONS - ROLLING STOCK - PROTECTIVE PROVISIONS RELATING TO ELECTRICAL HAZARDS |
EN 50122-2:2010 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRICAL SAFETY, EARTHING AND THE RETURN CIRCUIT - PART 2: PROVISIONS AGAINST THE EFFECTS OF STRAY CURRENTS CAUSED BY D.C. TRACTION SYSTEMS |
EN 50122-3:2010 | Railway applications - Fixed installations - Electrical safety, earthing and the return circuit - Part 3: Mutual Interaction of a.c. and d.c. traction systems |
HD 637 S1:1999/corrigendum:2005 | POWER INSTALLATIONS EXCEEDING 1 KV A.C. |
2008/57/EC : 2008 AMD 5 2014 | DIRECTIVE 2008/1957/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL OF 17 JUNE 2008 ON THE INTEROPERABILITY OF THE RAIL SYSTEM WITHIN THE COMMUNITY (RECAST) (TEXT WITH EEA RELEVANCE) |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60050-551:1998 | International Electrotechnical Vocabulary (IEV) - Part 551: Power electronics |
IEC 60050-442:1998 | International Electrotechnical Vocabulary (IEV) - Part 442: Electrical accessories |
IEC 60364-1:2005 | Low-voltage electrical installations - Part 1: Fundamental principles, assessment of general characteristics, definitions |
EN 50124-1:2017 | Railway applications - Insulation coordination - Part 1: Basic requirements - Clearances and creepage distances for all electrical and electronic equipment |
IEC 60050-101:1998 | International Electrotechnical Vocabulary (IEV) - Part 101: Mathematics |
EN 50119 : 2009 AMD 1 2013 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - ELECTRIC TRACTION OVERHEAD CONTACT LINES |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 50345:2009 | Railway applications - Fixed installations - Electric traction - Insulating synthetic rope assemblies for support of overhead contact lines |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60050-821:1998 | International Electrotechnical Vocabulary (IEV) - Part 821: Signalling and security apparatus for railways |
EN 50163 : 2004 COR 2013 | RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
ISO 3864-1:2011 | Graphical symbols Safety colours and safety signs Part 1: Design principles for safety signs and safety markings |
IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
IEC 60050-826:2004 | International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations |
EN 50388 : 2012 COR 2013 | RAILWAY APPLICATIONS - POWER SUPPLY AND ROLLING STOCK - TECHNICAL CRITERIA FOR THE COORDINATION BETWEEN POWER SUPPLY (SUBSTATION) AND ROLLING STOCK TO ACHIEVE INTEROPERABILITY |
EN 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60050-111:1996 | International Electrotechnical Vocabulary (IEV) - Part 111: Physics and chemistry |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.