Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C22.2 NO. 250.1:16 (R2020)

Current

Current

The latest, up-to-date edition.

Retrofit kits for luminaire conversion

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2016

Preface This is the first edition of CSA C22.2 No. 250.1, Retrofit kits for luminaire conversion . This Standard replaces the retrofit kit requirements of CSA TIL B-79A, Interim Certification Requirements for LED Retrofit Kits and Field Retrofitted Luminaires, and CSA TIL B-64A, Requirements for Retrofit Assemblies Employing Fluorescent, Self Ballasted (SBL) and Induction Lamp Retrofit Assemblies and Retrofitted Luminaires Utilizing Those Assemblies. This Standard is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The requirements for retrofit kits and retrofitted luminaires of this Standard supplement the requirements of the products covered by CSA C22.2 No. 250.0. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers the minimum safety requirements for retrofit kits intended to be installed as an alternate source of illumination in previously installed luminaires that already comply with the requirements of CSA C22.2 No. 250.0. Note: The types of retrofit kits covered are listed in Clause 1.2. 1.2 This Standard covers the following retrofit kit categories: a) LED (light emitting diode) retrofit kits and tubular LED lamp (TLED) retrofit kits, in accordance with the main body of this Standard; b) fluorescent lamp retrofit kits, in accordance with Annex B; c) induction lamp retrofit kits, in accordance with Annex C; and d) LED retrofit kits for commercial refrigeration equipment, in accordance with Annex D. 1.3 This Standard applies to retrofit kits only for the luminaire types that are covered by the scope of CSA C22.2 No. 250.0. Notes: 1) Retrofitting of a luminaire could involve relocation, removal, or replacement of wiring, reflectors, lampholders, ballasts, and the power supply of the original luminaire. 2) Conversion lamps that are intended to directly replace existing lamps without modification of the wiring, lampholders, or controlgear within the luminaire are specified in CSA C22.2 No. 1993. 1.4 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 The values given in SI units are the units of record for the purposes of this Standard. Where values are given in parentheses, they are for information and comparison only.

Preface This is the first edition of CSA C22.2 No. 250.1, Retrofit kits for luminaire conversion . This Standard replaces the retrofit kit requirements of CSA TIL B-79A, Interim Certification Requirements for LED Retrofit Kits and Field Retrofitted Luminaires, and CSA TIL B-64A, Requirements for Retrofit Assemblies Employing Fluorescent, Self Ballasted (SBL) and Induction Lamp Retrofit Assemblies and Retrofitted Luminaires Utilizing Those Assemblies. This Standard is one of a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. The requirements for retrofit kits and retrofitted luminaires of this Standard supplement the requirements of the products covered by CSA C22.2 No. 250.0. This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope 1.1 This Standard covers the minimum safety requirements for retrofit kits intended to be installed as an alternate source of illumination in previously installed luminaires that already comply with the requirements of CSA C22.2 No. 250.0. Note: The types of retrofit kits covered are listed in Clause 1.2. 1.2 This Standard covers the following retrofit kit categories: a) LED (light emitting diode) retrofit kits and tubular LED lamp (TLED) retrofit kits, in accordance with the main body of this Standard; b) fluorescent lamp retrofit kits, in accordance with Annex B; c) induction lamp retrofit kits, in accordance with Annex C; and d) LED retrofit kits for commercial refrigeration equipment, in accordance with Annex D. 1.3 This Standard applies to retrofit kits only for the luminaire types that are covered by the scope of CSA C22.2 No. 250.0. Notes: 1) Retrofitting of a luminaire could involve relocation, removal, or replacement of wiring, reflectors, lampholders, ballasts, and the power supply of the original luminaire. 2) Conversion lamps that are intended to directly replace existing lamps without modification of the wiring, lampholders, or controlgear within the luminaire are specified in CSA C22.2 No. 1993. 1.4 In this Standard, \"shall\" is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; \"should\" is used to express a recommendation or that which is advised but not required; and \"may\" is used to express an option or that which is permissible within the limits of the Standard. Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material. Notes to tables and figures are considered part of the table or figure and may be written as requirements. Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application. 1.5 The values given in SI units are the units of record for the purposes of this Standard. Where values are given in parentheses, they are for information and comparison only.

DocumentType
Standard
ISBN
978-1-4883-0256-5
Pages
57
PublisherName
Canadian Standards Association
Status
Current
Supersedes

View more information
$791.10
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more