Customer Support: 131 242

  • There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

CSA C22.2 NO. 80601-2-12:21

Current

Current

The latest, up-to-date edition.

Medical electrical equipment - Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators (Adopted ISO 80601-2-12-:2020, second edition, 2020-02, with Canadian deviations)

Available format(s)

Hardcopy , PDF

Language(s)

English, French

Published date

01-01-2021

CSA Preface This is the second edition of CSA C22.2 No. 80601-2-12, Medical electrical equipment — Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-12 (second edition, 2020-02). It supersedes the previous edition, published in 2012 as CAN/CSA-C22.2 No. 80601-2-12 (adopted ISO 80601-2-12:2011). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object Clause 1 of the general standard applies, except as follows: NOTE The general standard is IEC 60601-1:2005+AMD1:2012. 201.1.1 * Scope Replacement: This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment: - intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. Ventilators for this environment are considered life-sustaining. NOTE 2 For the purposes of this document, such a ventilator can provide transport within a professional healthcare facility (i.e. be a transit-operable ventilator). NOTE 3 A critical care ventilator intended for use in transport within a professional healthcare facility is not considered as an emergency medical services environment ventilator. - intended to be operated by a healthcare professional operator; and - intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients. A critical care ventilator is not considered to utilize a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator. NOTE 4 If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005, 7.2.13 and 8.4.1. NOTE 5 Additional information can be found in IEC 60601-1:2005 +AMD1:2012, 4.2. This document is not applicable to ME equipment or an ME system operating in a ventilator-operational mode solely intended for patients who are not dependent on artificial ventilation. NOTE 6 A critical care ventilator, when operating in such a ventilator-operational mode, is not considered life-sustaining. This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: - ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13[2]; - ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84[3], the future replacement for ISO 10651-3[4]; - ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72:2015[5]; - ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79:2018[6] and ISO 80601-2-80:2018[7] 1; - obstructive sleep apnoea therapy ME equipment, which are given in ISO 80601-2-70[9]; - continuous positive airway pressure (CPAP) ME equipment; - high-frequency jet ventilators (HFJVs) and high-frequency oscillatory ventilators (HFOVs), which are given in ISO 80601-2-87[63]; NOTE 7 A critical care ventilator can incorporate high-frequency jet or high-frequency oscillatory ventilator-operational modes. - oxygen therapy constant flow ME equipment; and - cuirass or \"iron-lung\" ventilation equipment. 201.1.2 Object Replacement: The object of this document is to establish basic safety and essential performance requirements for a ventilator and its accessories. Accessories are included because the combination of the ventilator and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of a ventilator. NOTE 1 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex CC. NOTE 2 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745 as indicated in Annex DD.

CSA Preface This is the second edition of CSA C22.2 No. 80601-2-12, Medical electrical equipment — Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators , which is an adoption, with Canadian deviations, of the identically titled ISO (International Organization for Standardization) Standard 80601-2-12 (second edition, 2020-02). It supersedes the previous edition, published in 2012 as CAN/CSA-C22.2 No. 80601-2-12 (adopted ISO 80601-2-12:2011). It is one in a series of Standards issued by CSA Group under Part II of the Canadian Electrical Code. This Standard is intended to be used in conjunction with CAN/CSA-C22.2 No. 60601-1:14, Medical electrical equipment — Part 1: General requirements for basic safety and essential performance (adopted IEC 60601-1:2005, including Amendment 1:2012, with Canadian deviations). This Standard has been developed in compliance with Standards Council of Canada requirements for National Standards of Canada. It has been published as a National Standard of Canada by CSA Group. Scope and object Clause 1 of the general standard applies, except as follows: NOTE The general standard is IEC 60601-1:2005+AMD1:2012. 201.1.1 * Scope Replacement: This document applies to the basic safety and essential performance of a ventilator in combination with its accessories, hereafter referred to as ME equipment: - intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare facility; NOTE 1 For the purposes of this document, such an environment is referred to as a critical care environment. Ventilators for this environment are considered life-sustaining. NOTE 2 For the purposes of this document, such a ventilator can provide transport within a professional healthcare facility (i.e. be a transit-operable ventilator). NOTE 3 A critical care ventilator intended for use in transport within a professional healthcare facility is not considered as an emergency medical services environment ventilator. - intended to be operated by a healthcare professional operator; and - intended for those patients who need differing levels of support from artificial ventilation including for ventilator-dependent patients. A critical care ventilator is not considered to utilize a physiologic closed-loop-control system unless it uses a physiological patient variable to adjust the ventilation therapy settings. This document is also applicable to those accessories intended by their manufacturer to be connected to a ventilator breathing system, or to a ventilator, where the characteristics of those accessories can affect the basic safety or essential performance of the ventilator. NOTE 4 If a clause or subclause is specifically intended to be applicable to ME equipment only, or to ME systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME equipment and to ME systems, as relevant. Hazards inherent in the intended physiological function of ME equipment or ME systems within the scope of this document are not covered by specific requirements in this document except in IEC 60601-1:2005, 7.2.13 and 8.4.1. NOTE 5 Additional information can be found in IEC 60601-1:2005 +AMD1:2012, 4.2. This document is not applicable to ME equipment or an ME system operating in a ventilator-operational mode solely intended for patients who are not dependent on artificial ventilation. NOTE 6 A critical care ventilator, when operating in such a ventilator-operational mode, is not considered life-sustaining. This document is not applicable to ME equipment that is intended solely to augment the ventilation of spontaneously breathing patients within a professional healthcare facility. This document does not specify the requirements for: - ventilators or accessories intended for anaesthetic applications, which are given in ISO 80601-2-13[2]; - ventilators or accessories intended for the emergency medical services environment, which are given in ISO 80601-2-84[3], the future replacement for ISO 10651-3[4]; - ventilators or accessories intended for ventilator-dependent patients in the home healthcare environment, which are given in ISO 80601-2-72:2015[5]; - ventilators or accessories intended for home-care ventilatory support devices, which are given in ISO 80601-2-79:2018[6] and ISO 80601-2-80:2018[7] 1; - obstructive sleep apnoea therapy ME equipment, which are given in ISO 80601-2-70[9]; - continuous positive airway pressure (CPAP) ME equipment; - high-frequency jet ventilators (HFJVs) and high-frequency oscillatory ventilators (HFOVs), which are given in ISO 80601-2-87[63]; NOTE 7 A critical care ventilator can incorporate high-frequency jet or high-frequency oscillatory ventilator-operational modes. - oxygen therapy constant flow ME equipment; and - cuirass or \"iron-lung\" ventilation equipment. 201.1.2 Object Replacement: The object of this document is to establish basic safety and essential performance requirements for a ventilator and its accessories. Accessories are included because the combination of the ventilator and the accessories needs to be adequately safe. Accessories can have a significant impact on the basic safety or essential performance of a ventilator. NOTE 1 This document has been prepared to address the relevant essential principles of safety and performance of ISO 16142-1:2016 as indicated in Annex CC. NOTE 2 This document has been prepared to address the relevant general safety and performance requirements of European regulation (EU) 2017/745 as indicated in Annex DD.

DocumentType
Standard
ISBN
978-1-4883-3883-0
Pages
164
ProductNote
This standard also refers to IEC 60601-1-3,IEC 60601-1-9,ASTM F2761-09,IEC/TR 60878:2015,IEC 60721-3-7:1995+AMD1:1996,ISO 594-1:19863,ISO 594-2:19983,ISO 80369-7:2016,IEC 80001-2-5:2014,ISO 80601-2-87,CAN/CSA-C22.2 No. 60601-1-2:16,CAN/CSA-C22.2 No. 60601-1-6:11 (R2016),CAN/CSA-C22.2 No. 60601-1-8:08 (R2018),CSA C22.2 No. 60601-2-2:19,CSA IEC 62304:14(R2019)CSA C22.2 No. 80601-2-55:14 (R2019)

PublisherName
Canadian Standards Association
Status
Current
Supersedes

Standards Relationship
ISO 80601-2-12:2020 Identical

View more information
$439.38
Including GST where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more