SN EN 61674 : 1997

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

MEDICAL ELECTRICAL EQUIPMENT - DOSIMETERS WITH IONIZATION CHAMBERS AND/OR SEMI-CONDUCTOR DETECTORS AS USED IN X-RAY DIAGNOSIS IMAGING

Withdrawn date

03-01-2016

Published date

12-01-2013

Foreword
Introduction
1 Scope and object
    1.1 Scope
    1.2 Object
2 Normative references
3 Terminology and definitions
4 General requirements
    4.1 Performance requirements
    4.2 REFERENCE VALUES and STANDARD TEST VALUES
    4.3 General test conditions
          4.3.1 STANDARD TEST CONDITIONS
          4.3.2 Statistical fluctuations
          4.3.3 STABILIZATION TIME
          4.3.4 Adjustments during test
          4.3.5 Batteries
    4.4 Constructional requirements as related to
          performance
          4.4.1 Components
          4.4.2 Display
          4.4.3 Indication of battery condition
          4.4.4 Indication of polarizing voltage failure
          4.4.5 Over-ranging
          4.4.6 Indication of reset or other inactive
                  condition
          4.4.7 MEASURING ASSEMBLIES with multiple
                  DETECTOR ASSEMBLIES
          4.4.8 Radioactive STABILITY CHECK DEVICE
    4.5 Uncertainty of measurement
5 Limits of PERFORMANCE CHARACTERISTICS
    5.1 RELATIVE INTRINSIC ERROR
    5.2 Repeatability
          5.2.1 Repeatability in the ATTENUATED BEAM
          5.2.2 Repeatability in the UNATTENUATED BEAM
    5.3 RESOLUTION of reading
    5.4 STABILIZATION time
    5.5 Effect of pulsed radiation on AIR KERMA and AIR
          KERMA LENGTH measurements
    5.6 Reset on AIR KERMA and AIR KERMA LENGTH ranges
    5.7 Effects of LEAKAGE CURRENT
    5.8 Stability
          5.8.1 Long term stability
          5.8.2 Accumulated dose stability
    5.9 Measurements with a radioactive STABILITY CHECK DEVICE
6 LIMITS OF VARIATION for effects of INFLUENCE QUANTITIES
    6.1 Energy dependence of RESPONSE
    6.2 AIR KERMA RATE dependence of AIR KERMA and AIR
          KERMA LENGTH measurements
          6.2.1 MEASURING ASSEMBLY
          6.2.2 IONIZATION CHAMBER - Recombination losses
    6.3 Dependence of DETECTOR RESPONSE on angle of
          incidence of radiation
    6.4 Operating voltage
    6.5 Air pressure
    6.6 Air pressure EQUILIBRATION TIME of the RADIATION
          DETECTOR
    6.7 Temperature and humidity
    6.8 Electromagnetic compatibility
          6.8.1 Electrostatic discharge
          6.8.2 Radiated electromagnetic fields
          6.8.3 Conducted disturbances induced by bursts
                  and radio frequencies
          6.8.4 Surges
          6.8.5 Voltage dips, short interruptions and voltage
                  variations
    6.9 Field size
    6.10 EFFECTIVE LENGTH and spatial uniformity of RESPONSE
          of CT DOSIMETERS
7 Marking
    7.1 DETECTOR ASSEMBLY
    7.2 MEASURING ASSEMBLY
    7.3 Radioactive STABILITY CHECK DEVICE
8 ACCOMPANYING DOCUMENTS
Annex A (informative) Bibliography
Annex B (informative) Index of defined terms
Annex ZA (normative) Normative references to international
                      publications with their corresponding
                      European publications

Defines the performance and some related constructional requirements of diagnostic dosimeters, as specified in 3.1, for measuring or air kerma, air kerma length or air kerma rate in photon radiation fields in radiography. Includes mammography, radioscopy and computed tomography (CT) for X-rays having generating potentials not in excess of 150 kV. Applies to the performance of dosimeters with ionization chambers and/or semi-conductor detectors as in X-ray diagnostic imaging.

DocumentType
Standard
PublisherName
Swiss Standards
Status
Withdrawn
SupersededBy

Standards Relationship
BS EN 61674:2013 Identical
IEC 61674:2012 Identical
NBN EN 61674 : 2013 Identical
NF EN 61674 : 2013 Identical
I.S. EN 61674:2013 Identical
EN 61674:2013 Identical
DIN EN 61674:2015-11 Identical
UNE-EN 61674:2003 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

Need help?
Call us on 131 242, then click here to start a Screen Sharing session
so we can help right away! Learn more