• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

11/30211183 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS ISO 16422 - PIPES AND JOINTS MADE OF ORIENTED UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-O) FOR THE CONVEYANCE OF WATER UNDER PRESSURE - SPECIFICATIONS

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

28-02-2014

Superseded by

BS ISO 16422:2014

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Material
6 Effect of materials on water quality
7 Material classification
8 Classification and selection of pipes
9 General requirements for pipes
10 Geometrical characteristics for pipes
11 Mechanical characteristics of pipes
12 Physical characteristics
13 Mechanical characteristics of assemblies, including
   joints
14 Elastomeric seals
15 Marking
Annex A (normative) - Establishment of the pipe
        material classification
Annex B (informative) - Minimum depth of engagement
        of sockets
Annex C (normative) - Temperature derating factor
Annex D (informative) - Ring stiffness of pipes
Annex E (informative) - Determination of the long-term
        test pressure by creep consideration
Annex F (informative) - Determination of axial and tangential
        orientation factor

BS ISO 16422.

Committee
PRI/88/2
DocumentType
Draft
Pages
35
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

ISO 2507-2:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 2: Test conditions for unplasticized poly(vinyl chloride) (PVC-U) or chlorinated poly(vinyl chloride) (PVC-C) pipes and fittings and for high impact resistance poly (vinyl chloride) (PVC-HI) pipes
ISO 6259-2:1997 Thermoplastics pipes — Determination of tensile properties — Part 2: Pipes made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly (vinyl chloride) (PVC-C) and high-impact poly (vinyl chloride) (PVC-HI)
ISO 13846:2000 Plastics piping systems — End-load-bearing and non-end-load-bearing assemblies and joints for thermoplastics pressure piping — Test method for long-term leaktightness under internal water pressure
ISO 2507-1:1995 Thermoplastics pipes and fittings — Vicat softening temperature — Part 1: General test method
ISO 3127:1994 Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method
ISO 161-1:1996 Thermoplastics pipes for the conveyance of fluids — Nominal outside diameters and nominal pressures — Part 1: Metric series
ISO 9080:2012 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
ISO 3:1973 Preferred numbers — Series of preferred numbers
ISO 1452-5:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 5: Fitness for purpose of the system
ISO 12162:2009 Thermoplastics materials for pipes and fittings for pressure applications — Classification, designation and design coefficient
ISO 3126:2005 Plastics piping systems — Plastics components — Determination of dimensions
ISO 11922-1:1997 Thermoplastics pipes for the conveyance of fluids — Dimensions and tolerances — Part 1: Metric series
ISO 13783:1997 Plastics piping systems — Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double-socket joints — Test method for leaktightness and strength while subjected to bending and internal pressure
ISO 13844:2015 Plastics piping systems — Elastomeric-sealing-ring-type socket joints for use with plastic pressure pipes — Test method for leaktightness under negative pressure, angular deflection and deformation
ISO 1452-2:2009 Plastics piping systems for water supply and for buried and above-ground drainage and sewerage under pressure — Unplasticized poly(vinyl chloride) (PVC-U) — Part 2: Pipes
ISO 18373-1:2007 Rigid PVC pipes — Differential scanning calorimetry (DSC) method — Part 1: Measurement of the processing temperature
ISO 1628-2:1998 Plastics — Determination of the viscosity of polymers in dilute solution using capillary viscometers — Part 2: Poly(vinyl chloride) resins
ISO 4065:1996 Thermoplastics pipes — Universal wall thickness table
ISO 9969:2016 Thermoplastics pipes — Determination of ring stiffness
ISO 2531:2009 Ductile iron pipes, fittings, accessories and their joints for water applications
ISO 4633:2015 Rubber seals — Joint rings for water supply, drainage and sewerage pipelines — Specification for materials
ISO 9852:2007 Unplasticized poly(vinyl chloride) (PVC-U) pipes — Dichloromethane resistance at specified temperature (DCMT) — Test method
ISO 7686:2005 Plastics pipes and fittings — Determination of opacity
ISO 1167-1:2006 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids — Determination of the resistance to internal pressure — Part 1: General method
ISO 2505:2005 Thermoplastics pipes — Longitudinal reversion — Test method and parameters
ISO 13845:2015 Plastics piping systems — Elastomeric-sealing-ring-type socket joints for use with thermoplastic pressure pipes — Test method for leaktightness under internal pressure and with angular deflection

£20.00
Excluding VAT