• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

11/30247086 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS EN 60079-1 ED. 7.0 - EXPLOSIVE ATMOSPHERES - PART 1: EQUIPMENT PROTECTION BY FLAMEPROOF ENCLOSURES "D"

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

31-07-2011

Superseded by

BS EN 60079-1:2014

£20.00
Excluding VAT

1 Scope
2 Normative references
3 Terms and definitions
4 Level of protection (Equipment protection level (EPL) )
5 Flameproof joints
6 Sealed joints
7 Operating rods
8 Supplementary requirements for shafts and bearings
9 Light-transmitting parts
10 Breathing and draining devices which form part of a
   flameproof enclosure
11 Fasteners and openings
12 Materials and mechanical strength of enclosures -
   Materials inside the enclosures
13 Entries for flameproof enclosures
14 Verification and tests
15 Type tests
16 Routine tests
17 Switchgear for group I
18 Lampholders and Iamp caps
19 Non-metallic enclosures and non-metallic parts
   of enclosures
20 Marking
21 Instructions
Annex A (normative) - Additional requirements for crimped
        ribbon elements and multiple screen elements of
        breathing and draining devices
Annex B (normative) - Additional requirements for elements,
        with non-measurable paths, of breathing and
        draining devices
Annex C (normative) - Additional requirements for
        flameproof entry devices
Annex D (normative) - Empty flameproof enclosures as Ex
        components
Annex E (normative) - Cells and batteries used in
        flameproof "d" enclosures
Annex F (informative) - Mechanical properties for screws
        and nuts
Annex G (normative) - Additional requirements for
        Flameproof enclosures with an internal source of
        release (containment system)
Annex H (normative) - Requirements for machines with
        flameproof "d" enclosures fed from converters
Bibliography

BS EN 60079-1 ED. 7.0.

Committee
GEL/31/X
DocumentType
Draft
Pages
82
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC 60112:2003+AMD1:2009 CSV Method for the determination of the proof and the comparative tracking indices of solid insulating materials
ISO 2738:1999 Sintered metal materials, excluding hardmetals — Permeable sintered metal materials — Determination of density, oil content and open porosity
IEC 60662:2011 High-pressure sodium vapour lamps - Performance specifications
ISO 4003:1977 Permeable sintered metal materials — Determination of bubble test pore size
IEC 60079-18:2014 RLV Explosive atmospheres - Part 18: Equipment protection by encapsulation “m”
IEC 61241-0:2004 Electrical apparatus for use in the presence of combustible dust - Part 0: General requirements
IEC 61241-11:2005 Electrical apparatus for use in the presence of combustible dust - Part 11: Protection by intrinsic safety 'iD'
IEC 60079-20-1:2010 Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data
IEC 60079-5:2015 RLV Explosive atmospheres - Part 5: Equipment protection by powder filling "q"
IEC 60050-426:2008 International Electrotechnical Vocabulary (IEV) - Part 426: Equipment for explosive atmospheres
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 61951-2:2017 Secondary cells and batteries containing alkaline or other non acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 2: Nickel-metal hydride
ISO 4022:1987 Permeable sintered metal materials — Determination of fluid permeability
IEC 61951-1:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Secondary sealed cells and batteries for portable applications - Part 1: Nickel-Cadmium
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 468:1982 Surface roughness — Parameters, their values and general rules for specifying requirements
IEC 60695-11-10:2013 Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods
IEC 61241-18:2004 Electrical apparatus for use in the presence of combustible dust - Part 18: Protection by encapsulation 'mD'
IEC 60079-6:2015 Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o"
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements
ISO 80000-1:2009 Quantities and units — Part 1: General
IEC 60034-1:2017 Rotating electrical machines - Part 1: Rating and performance
IEC 60086-1:2015 Primary batteries - Part 1: General
IEC 60079-14:2013 Explosive atmospheres - Part 14: Electrical installations design, selection and erection
IEC 61241-4:2001 Electrical apparatus for use in the presence of combustible dust - Part 4: Type of protection "pD"
ISO 185:2005 Grey cast irons — Classification
ISO 965-1:2013 ISO general purpose metric screw threads — Tolerances — Part 1: Principles and basic data
ISO 965-3:1998 ISO general purpose metric screw threads — Tolerances — Part 3: Deviations for constructional screw threads
IEC 60623:2017 Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells
ISO 3864:1984 Safety colours and safety signs
IEC 60079-15:2010 Explosive atmospheres - Part 15: Equipment protection by type of protection "n"
IEC 60079-26:2014 RLV Explosive atmospheres - Part 26: Equipment with Equipment Protection Level (EPL) Ga
IEC 61241-10:2004 Electrical apparatus for use in the presence of combustible dust - Part 10: Classification of areas where combustible dusts are or may be present

£20.00