BS ISO 13675 - HEATING AND COOLING SYSTEMS IN BUILDINGS - METHOD AND DESIGN FOR CALCULATION OF THE SYSTEM ENERGY PERFORMANCE - COMBUSTION SYSTEMS (BOILERS)

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

28-02-2014

Superseded by

BS ISO 13675:2013

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Alignment of the parts of the heating
  system standards
5 Generation sub-system calculation
Annex A (informative) - Additional formulas and
        default values for parametering the boiler
        efficiency method
Annex B (informative) - General part default values and
        information
Annex C (normative) - Maximum heating power in the building
        zone
Annex D (informative) - Calculation examples for modulating
        condensing boiler
Annex E (informative) - Default values for parametering
        the boiler cycling method
Annex F (informative) - generation sub-systems and gross
        calorific values
Bibliography

BS ISO 13675.

Committee
RHE/2
DocumentType
Draft
Pages
59
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

EN 13836:2006 Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW
EN 15316-3-3:2007 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 3-3: Domestic hot water systems, generation
EN 303-6:2000 Heating boilers - Part 6: Heating boilers with forced draught burners - Specific requirements for the domestic hot water operation of combination boilers with atomizing oil burners of nominal heat input not exceeding 70 kW
EN 677:1998 Gas-fired central heating boilers - Specific requirements for condensing boilers with a nominal heat input not exceeding 70 kW
ISO 9488:1999 Solar energy — Vocabulary
EN 304:2017 Heating boilers - Test code for heating boilers for atomizing oil burners
EN 15316-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 1: General and Energy performance expression, Module M3-1, M3-4, M3-9, M8-1, M8-4
EN 15456:2008 Heating boilers - Electrical power consumption for heat generators - System boundaries - Measurements
EN 303-1:2017 Heating boilers - Part 1: Heating boilers with forced draught burners - Terminology, general requirements, testing and marking
EN ISO 13790:2008 Energy performance of buildings - Calculation of energy use for space heating and cooling (ISO 13790:2008)
EN 303-5:2012 Heating boilers - Part 5: Heating boilers for solid fuels, manually and automatically stoked, nominal heat output of up to 500 kW - Terminology, requirements, testing and marking
EN 15316-4-7:2008 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-7: Space heating generation systems, biomass combustion systems
EN 267:2009+A1:2011 Automatic forced draught burners for liquid fuels
EN 303-2:2017 Heating boilers - Part 2: Heating boilers with forced draught burners - Special requirements for boilers with atomizing oil burners
ISO 13602-2:2006 Technical energy systems — Methods for analysis — Part 2: Weighting and aggregation of energywares
EN 15316-2-1:2007 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 2-1: Space heating emission systems
EN ISO 9488:1999 Solar energy - Vocabulary (ISO 9488:1999)
EN 303-4:1999 Heating boilers - Part 4: Heating boilers with forced draught burners - Special requirements for boilers with forced draught oil burners with outputs up to 70 kW and a maximum operating pressure of 3 bar - Terminology, special requirements, testing and marking
92/42/EEC : 1992 AMD 5 2013 COUNCIL DIRECTIVE 92/42/EEC OF 21 MAY 1992 ON EFFICIENCY REQUIREMENTS FOR NEW HOT-WATER BOILERS FIRED WITH LIQUID OR GASEOUS FUELS
EN 303-7:2006 Heating boilers - Part 7: Gas-fired central heating boilers equipped with a forced draught burner of nominal heat output not exceeding 1 000 kW
EN 15316-3-2:2007 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 3-2: Domestic hot water systems, distribution
ISO 13790:2008 Energy performance of buildings — Calculation of energy use for space heating and cooling
EN 15035:2006 Heating boilers - Special requirements for oil fired room sealed units up to 70 kW
EN 15316-4-1:2017 Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 4-1: Space heating and DHW generation systems, combustion systems (boilers, biomass), Module M3-8-1, M8-8-1
ISO 7345:1987 Thermal insulation — Physical quantities and definitions
EN 15316-2-3:2007 Heating systems in buildings - Method for calculation of system energy requirements and system efficiencies - Part 2-3: Space heating distribution systems
EN 625:1995 Gas-fired central heating boilers - Specific requirements for the domestic hot water operation of combination boilers of nominal heat input not exceeding 70 kW

£20.00