13/30244707 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS IEC 61005 ED 3.0 - RADIATION PROTECTION INSTRUMENTATION - NEUTRON AMBIENT DOSE EQUIVALENT (RATE) METERS

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

31-03-2017

Superseded by

BS EN 61005:2004

£20.00
Excluding VAT

Foreword
1 Scope
2 Normative references
3 Terms and definitions, abbreviations and symbols,
   quantities and units
4 General test procedure
5 General requirements
6 Radiation detection requirements
7 Additivity of indicated value
8 Software
9 Electrical characteristics
10 Environmental requirements
11 Mechanical requirements
12 Electromagnetic requirements
13 Documentation
Annex A (informative) - Neutron fluence-to-ambient dose
        equivalent conversion coefficients
Annex B (informative) - Procedure to determine the
        variation of the relative response due to radiation
        energy and angle of radiation incidence
Bibliography

BS IEC 61005 ED 3.0

Committee
NCE/2
DocumentType
Draft
Pages
48
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

IEC TR 62461:2015 Radiation protection instrumentation - Determination of uncertainty in measurement
IEC 61187:1993 Electrical and electronic measuring equipment - Documentation
ISO 8529-3:1998 Reference neutron radiations — Part 3: Calibration of area and personal dosimeters and determination of response as a function of energy and angle of incidence
ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
ISO 8529-2:2000 Reference neutron radiations — Part 2: Calibration fundamentals of radiation protection devices related to the basic quantities characterizing the radiation field
ISO 12789-2:2008 Reference radiation fields — Simulated workplace neutron fields — Part 2: Calibration fundamentals related to the basic quantities
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60086-2:2015 Primary batteries - Part 2: Physical and electrical specifications
IEC 60086-1:2015 Primary batteries - Part 1: General
ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 1: Radiation characteristics and production methods
ISO 8529-1:2001 Reference neutron radiations — Part 1: Characteristics and methods of production
ISO 11929:2010 Determination of the characteristic limits (decision threshold, detection limit and limits of the confidence interval) for measurements of ionizing radiation — Fundamentals and application
ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy — Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
ISO 12789-1:2008 Reference radiation fields — Simulated workplace neutron fields — Part 1: Characteristics and methods of production

£20.00