• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

15/30282559 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS EN ISO 11137-3 - STERILIZATION OF HEALTH CARE PRODUCTS - RADIATION - PART 3: GUIDANCE ON DOSIMETRIC ASPECTS OF DEVELOPMENT, VALIDATION AND ROUTINE CONTROL

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

31-08-2017

Superseded by

BS EN ISO 11137-3:2017

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative References
3 Terms and definitions
4 Measurement of Dose
5 Measurement of dose to product
6 Establishing the maximum acceptable dose
7 Establishing the sterilization dose
8 Installation qualification
9 Operational qualification
10 Performance qualification
11 Routine monitoring and control
Annex A (informative) - Mathematical modelling
Annex B (informative) - Tables of references for
        dosimetry-related testing during IQ/OQ/PQ
Annex C (informative) - Tolerances associated
        with doses used in sterilization dose setting/
        substantiation in ISO 11137-2
Annex D (informative) - Establishment and application
        of total uncertainty, sigma[total]
Bibliography

BS EN ISO 11137-3.

Committee
CH/198
DocumentType
Draft
Pages
46
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

ISO/TS 13004:2013 Sterilization of health care products — Radiation — Substantiation of selected sterilization dose: Method VDmaxSD
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 11137-1:2006 Sterilization of health care products — Radiation — Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices
ISO/ASTM 51401:2013 Practice for use of a dichromate dosimetry system
ISO/ASTM 51650:2013 Practice for use of a cellulose triacetate dosimetry system
ISO 11462-2:2010 Guidelines for implementation of statistical process control (SPC) — Part 2: Catalogue of tools and techniques
ISO/ASTM 51276:2012 Practice for use of a polymethylmethacrylate dosimetry system
ISO/ASTM 51818:2013 Practice for dosimetry in an electron beam facility for radiation processing at energies between 80 and 300 keV
ISO/ASTM 51261:2013 Practice for calibration of routine dosimetry systems for radiation processing
ISO 14253-1:2017 Geometrical product specifications (GPS) — Inspection by measurement of workpieces and measuring equipment — Part 1: Decision rules for verifying conformity or nonconformity with specifications
ISO 13485:2016 Medical devices — Quality management systems — Requirements for regulatory purposes
ISO/ASTM 51275:2013 Practice for use of a radiochromic film dosimetry system
ISO/ASTM 51608:2015 Practice for dosimetry in an X-ray (bremsstrahlung) facility for radiation processing at energies between 50 keV and 7.5 MeV
ASTM E 2232 : 2016 : REDLINE Standard Guide for Selection and Use of Mathematical Methods for Calculating Absorbed Dose in Radiation Processing Applications
ISO/ASTM 52701:2013 Guide for performance characterization of dosimeters and dosimetry systems for use in radiation processing
ISO/ASTM 51607:2013 Practice for use of the alanine-EPR dosimetry system
ISO 9001:2015 Quality management systems — Requirements
ISO/ASTM 51649:2015 Practice for dosimetry in an electron beam facility for radiation processing at energies between 300 keV and 25 MeV
ISO/ASTM 51707:2015 Guide for estimation of measurement uncertainty in dosimetry for radiation processing
ISO/ASTM 52628:2013 Standard practice for dosimetry in radiation processing
ISO/ASTM 51631:2013 Practice for use of calorimetric dosimetry systems for electron beam dose measurements and dosimetery system calibrations

£20.00
Excluding VAT