15/30323334 DC : 0

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

BS EN 14825 - AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS, WITH ELECTRICALLY DRIVEN COMPRESSORS, FOR SPACE HEATING AND COOLING - TESTING AND RATING AT PART LOAD CONDITIONS AND CALCULATION OF SEASONAL PERFORMANCE

Available format(s)

Hardcopy , PDF

Language(s)

English

Superseded date

31-03-2016

Superseded by

BS EN 14825:2016

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols, abbreviated
   terms and units
4 Part load conditions in cooling mode
5 Part load conditions in heating mode
6 Calculation methods for SEER
   and SEERon
7 Calculation methods for seasonal
   space heating efficiency eta[s], SCOP, SCOPon
   and SCOPnet
8 Test methods for testing capacities, EER[bin]
   and COPbin values during active mode at part
   load conditions
9 Test methods for electric power consumption
   during thermostat-off mode, standby mode
   and crankcase heater mode
10 Test report
11 Technical data sheet
Annex A (normative) - Applicable climate bin hours
        and hours for active mode, thermostat-off,
        standby, off mode and crankcase heater
        mode for air conditioners below and equal
        to 12 kW
Annex B (normative) - Applicable climate bin hours
        and hours for active, thermostat-off, standby,
        off and crankcase heater modes for space
        heaters, air to water and water/brine to water
        units, belo or equal to 400 kW
Annex C (normative) - Template for technical
        data sheet
Annex D (informative) - Adaption of water
        temperature for fixed capacity units
Annex E (informative) - Calculation example
        for SEERon and SEER - Application to
        a reversible air-to-air unit with variable capacity
Annex F (informative) - Calculation example
        for SCOPon and SCOPnet - Application to a
        fixed capacity air-to-water heat pump used
        for floor heating
Annex G (informative) - Calculation example
        for SCOPon
        and SCOPnet - Application to a fixed
        capacity brinetowater heat pump used for
        medium temperature application
Annex H (informative) - Compensation methods for
        air-to-water and water/brine-to-water units
Annex ZA (informative) - Relationship between this
         European Standard and the requirements of
         Commission Regulation (EC) No 813/2013 and
         Commission Delegated Regulation (EU) No
         811/2013
Bibliography

BS EN 14825.

Committee
RHE/17
DocumentType
Draft
Pages
88
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

£20.00