• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

15/30328750 DC : 0

NA

NA

Status of Standard is Unknown

BS EN 14511-3 - AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS, WITH ELECTRICALLY DRIVEN COMPRESSORS - PART 3: TEST METHODS

Available format(s)

Hardcopy , PDF

Language(s)

English

£20.00
Excluding VAT

European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Rating capacity test
5 Electrical consumptions for single duct and double
  duct units
6 Air flow rate measurement of ducted units
7 Heat recovery test for air-cooled multisplit systems
8 Test report
Annex A (normative) - Calorimeter test method
Annex B (informative) - Indoor air enthalpy test method
Annex C (informative) - Heating capacity tests - Flow chart
        and examples of different test
sequences
Annex D (informative) - Conformance criteria
Annex E (informative) - Symbols used in annexes
Annex F (informative) - Test at system reduced capacity
Annex G (informative) - Individual unit tests
Annex H (normative) - Determination of the liquid pump
        efficiency
Annex I (informative) - Rating of indoor and outdoor units
        of multisplit and modular heat
Annex J (normative) - Air flow rate measurement
Annex ZA (informative) - Relationship between this European
         Standard and the requirements of Commission regulation
         (EC) No 206/2012 and Commission delegated Regulation
         (EU) No 626/2011
Bibliography

BS EN 14511-3.

Committee
RHE/17
DocumentType
Draft
Pages
59
PublisherName
British Standards Institution
Status
NA

Standards Relationship
PREN 14511-3 : DRAFT 2015 Identical

EN 14825:2016 Air conditioners, liquid chilling packages and heat pumps, with electrically driven compressors, for space heating and cooling - Testing and rating at part load conditions and calculation of seasonal performance
ISO 5801:2017 Fans — Performance testing using standardized airways
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full — Part 1: General principles and requirements
PREN 14511-2 : DRAFT 2015 AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS WITH ELECTRICALLY DRIVEN COMPRESSORS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS, USING ELECTRICALLY DRIVEN COMPRESSORS - PART 2: TEST CONDITIONS
CEN ISO/TS 16491:2012 Guidelines for the evaluation of uncertainty of measurement in air conditioner and heat pump cooling and heating capacity tests (ISO/TS 16491:2012)
PREN 14511-1 : DRAFT 2015 AIR CONDITIONERS, LIQUID CHILLING PACKAGES AND HEAT PUMPS FOR SPACE HEATING AND COOLING AND PROCESS CHILLERS USING ELECTRICALLY DRIVEN COMPRESSORS - PART 1: TERMS AND DEFINITIONS

£20.00
Excluding VAT