17/30313376 DC : DRAFT SEP 2017

Current

Current

The latest, up-to-date edition.

BS ISO 19916-1 - GLASS IN BUILDING - VACUUM INULATING GLASS - PART 1: BASIC SPECIFICATION OF PRODUCTS AND EVALUATION METHODS FOR THERMAL AND SOUND INSULATING PERFORMANCE

Published date

26-09-2017

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Description of components
5 Optical and thermal properties
6 Dimensional requirements
7 Tests of durability
8 Measurement of sound insulation
Annex A (normative) - Determination of
        steady-state U-value (thermal
        transmittance) - Heat flow meter
        method and guarded hot plate method
Annex B (normative) - Test method for durability
Annex C (informative) - Calculation method for
        thermal transmittance (U-value)
Annex D (informative) - Contribution from the
        edges to the measurement of the thermal
        transmittance (U-value) of vacuum insulating
        glass
Annex E (informative) - Maximum deviation in the
        measured thermal transmittance (U-value)
        of a VIG due to non-uniformities in the heat
        flow through the pillar array
Bibliography

BS ISO 19916-1.

Committee
B/520
DocumentType
Draft
PublisherName
British Standards Institution
Status
Current

ISO 10140-2:2010 Acoustics — Laboratory measurement of sound insulation of building elements — Part 2: Measurement of airborne sound insulation
ISO 16293-3:2017 Glass in building — Basic soda lime silicate glass products — Part 3: Polished wired glass
ISO 12543-3:2011 Glass in building — Laminated glass and laminated safety glass — Part 3: Laminated glass
ISO 12543-2:2011 Glass in building — Laminated glass and laminated safety glass — Part 2: Laminated safety glass
ISO 8302:1991 Thermal insulation — Determination of steady-state thermal resistance and related properties — Guarded hot plate apparatus
ISO 12540:2017 Glass in building — Tempered soda lime silicate safety glass
ISO 8301:1991 Thermal insulation — Determination of steady-state thermal resistance and related properties — Heat flow meter apparatus
ISO 9050:2003 Glass in building — Determination of light transmittance, solar direct transmittance, total solar energy transmittance, ultraviolet transmittance and related glazing factors
ISO 16293-5:2016 Glass in building — Basic soda lime silicate glass products — Part 5: Patterned glass
ISO 12543-4:2011 Glass in building — Laminated glass and laminated safety glass — Part 4: Test methods for durability
ISO 717-1:2013 Acoustics — Rating of sound insulation in buildings and of building elements — Part 1: Airborne sound insulation
ISO 20657:2017 Glass in building — Heat soaked tempered soda lime silicate safety glass
ISO 20492-1:2008 Glass in buildings - Insulating glass — Part 1: Durability of edge seals by climate tests
ISO 10292:1994 Glass in building — Calculation of steady-state U values (thermal transmittance) of multiple glazing
ISO 16293-2:2017 Glass in building — Basic soda lime silicate glass products — Part 2: Float glass