17/30331680 DC : 0

NA

NA

Status of Standard is Unknown

BS ISO 18095 - CONDITION MONITORING AND DIAGNOSTICS OF POWER TRANSFORMERS

Available format(s)

Hardcopy , PDF

Language(s)

English

£20.00
Excluding VAT

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols (and abbreviated terms)
5 Approach to selecting appropriate condition monitoring
   techniques
6 Power transformer types
7 Power transformer failure mode analysis
8 Range of techniques
9 Overview of techniques for condition monitoring power
   transformers
10 Establishing the programme
Annex A (informative) - Factors influencing the life of paper-based
        insulation and the role of transformer oil analysis/dissolved
        gas analysis (DGA)
Annex B (informative) - Example of typical condition monitoring
        programme - output as a result of use of this document
Annex C (informative) - Failure mode and symptoms
        analysis (FMSA)
Bibliography

BS ISO 18095.

Committee
GME/21/7
DocumentType
Draft
Pages
59
PublisherName
British Standards Institution
Status
NA

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 60076-7:2005 Power transformers - Part 7: Loading guide for oil-immersed power transformers
IEC 62021-1:2003 Insulating liquids - Determination of acidity - Part 1: Automatic potentiometric titration
IEC 62021-2:2007 Insulating liquids - Determination of acidity - Part 2: Colourimetric titration
IEEE 62-1995 IEEE Guide for Diagnostic Field Testing of Electric Power Apparatus - Part 1: Oil Filled Power Transformers, Regulators, and Reactors
IEC 60422:2013 Mineral insulating oils in electrical equipment - Supervision and maintenance guidance
IEC 60156:1995 Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
IEC 60599:2015 Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis
IEC 60076-10:2016 Power transformers - Part 10: Determination of sound levels
IEC 60076-18:2012 Power transformers - Part 18: Measurement of frequency response
IEC 60076-5:2006 Power transformers - Part 5: Ability to withstand short circuit
IEEE C57.149-2012 IEEE Guide for the Application and Interpretation of Frequency Response Analysis for Oil-Immersed Transformers
IEC 62535:2008 Insulating liquids - Test method for detection of potentially corrosive sulphur in used and unused insulating oil
IEEE C57.155-2014 IEEE Guide for Interpretation of Gases Generated in Natural Ester and Synthetic Ester-Immersed Transformers
IEEE C57.19.00 : 2004 GENERAL REQUIREMENTS AND TEST PROCEDURE FOR POWER APPARATUS BUSHINGS
IEC 60567:2011 Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance
IEC 60076-4:1976 Power transformers - Part 4: Tappings and connections
IEC 60076-8:1997 Power transformers - Part 8: Application guide
IEC 60296:2012 RLV Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
IEEE C57.104-2008 IEEE Guide for the Interpretation of Gases Generated in Oil-Immersed Transformers
IEC 60970:2007 Insulating liquids - Methods for counting and sizing particles
ISO 13372:2004 Condition monitoring and diagnostics of machines — Vocabulary
IEEE C57.143-2012 IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components
IEC 60076-3:2013 Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air
ISO 29821-1:2011 Condition monitoring and diagnostics of machines — Ultrasound — Part 1: General guidelines
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 60076-6:2007 Power transformers - Part 6: Reactors
IEC 62697-1:2012 Test methods for quantitative determination of corrosive sulfur compounds in unused and used insulating liquids - Part 1: Test method for quantitative determination of dibenzyldisulfide (DBDS)
IEC 60814:1997 Insulating liquids - Oil-impregnated paper and pressboard - Determination of water by automatic coulometric Karl Fischer titration
IEC 60076-2:2011 Power transformers - Part 2: Temperature rise for liquid-immersed transformers
IEC 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
ISO 2049:1996 Petroleum products — Determination of colour (ASTM scale)
IEC 61619:1997 Insulating liquids - Contamination by polychlorinated biphenyls (PCBs) - Method of determination by capillary column gas chromatography
IEEE C57.12.10-2010 REDLINE IEEE Standard Requirements for Liquid-Immersed Power Transformers
ISO 18434-1:2008 Condition monitoring and diagnostics of machines — Thermography — Part 1: General procedures
IEEE C57.152-2013 IEEE Guide for Diagnostic Field Testing of Fluid-Filled Power Transformers, Regulators, and Reactors
ISO 17359:2011 Condition monitoring and diagnostics of machines — General guidelines
IEC 60214-2:2004 Tap-changers - Part 2: Application guide
IEC 60214-1:2014 Tap-changers - Part 1: Performance requirements and test methods