AAMI ISO 11135-1 : 2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

STERILIZATION OF HEALTH CARE PRODUCTS - ETHYLENE OXIDE - PART 1: REQUIREMENTS FOR THE DEVELOPMENT, VALIDATION AND ROUTINE CONTROL OF A STERILIZATION PROCESS FOR MEDICAL DEVICES

Available format(s)

PDF

Language(s)

English

Published date

01-01-2007

Superseded date

10-09-2015

Superseded by

ANSI/AAMI/ISO 11135:2014

£132.87
Excluding VAT
Summarise this standard

Glossary of equivalent standards
Committee representation
Background of AAMI adoption of ISO 11135-1:2007
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Quality management systems
   4.1 Documentation
   4.2 Management responsibility
   4.3 Product realization
   4.4 Measurement, analysis and improvement - Control of
        nonconforming product
5 Sterilizing agent characterization
   5.1 Sterilizing agent
   5.2 Microbicidal effectiveness
   5.3 Material effects
   5.4 Environmental considerations
6 Process and equipment characterization
   6.1 Process characterization
   6.2 Equipment characterization
7 Product definition
   7.1 General
   7.2 Product safety and performance
   7.3 Microbiological quality
   7.4 Documentation
8 Process definition
9 Validation
   9.1 Installation qualification
   9.2 Operational qualification
   9.3 Performance qualification
   9.4 Varying load configurations
   9.5 Review and approval of validation
10 Routine monitoring and control
11 Product release from sterilization
12 Maintaining process effectiveness
   12.1 General
   12.2 Maintenance of equipment
   12.3 Requalification
   12.4 Assessment of change
Annex A (normative) Determination of lethal rate of the
        sterilization process - Biological indicator/bioburden
        approach
Annex B (normative) Conservative determination of lethal
        rate of the sterilization process - Overkill
        approach
Annex C (informative) General guidance
Bibliography

Specifies requirements for the development, validation, and routine control of an ethylene oxide sterilization process for medical devices.

Committee
WG 01
DevelopmentNote
Supersedes AAMI ISO 11135:1994. (08/2007)
DocumentType
Standard
Pages
63