• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AAMI TIR26 : 2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

VENTRICULAR ASSIST AND HEART REPLACEMENT SYSTEMS

Available format(s)

PDF

Language(s)

English

Published date

16-10-2000

Superseded date

08-03-2010

£57.04
Excluding VAT
Summarise this standard

Committee representation
Foreword
Introduction
1 Scope
2 References
3 Definitions and abbreviations
4 Intended clinical use and indications
5 System description
   5.1 Principle of operation
   5.2 Design consideration
   5.3 System configuration
   5.4 System performance and operating limits
   5.5 Design analysis
   5.6 Risk analysis
   5.7 Human factors
        5.7.1 General
        5.7.2 Specific human factors considerations
6 In vitro design evaluation
   6.1 In vitro test setup
   6.2 "Worst-case" operating conditions
   6.3 Fluid dynamics
   6.4 Software verification and validation
   6.5 Electrical qualification
        6.5.1 Electromagnetic compatibility
        6.5.2 Electrical safety
   6.6 Power sources
        6.6.1 Transcutaneous energy transmission systems
        6.6.2 Batteries
   6.7 Mechanical qualification
        6.7.1 Connections and connectors
               6.7.1.1 Electrical
               6.7.1.2 Pneumatic/gas
               6.7.1.3 Blood/conduits
        6.7.2 Vascular grafts
        6.7.3 Valves
        6.7.4 Materials qualification
   6.8 Biocompatibility
   6.9 Environmental testing
7 In vivo design evaluation
   7.1 In vivo study plan
   7.2 In vivo protocol
   7.3 In vivo analysis plan
8 Reliability
9 Clinical trial considerations
10 Labeling
   10.1 General
   10.2 Instructions for use
        10.2.1 General
        10.2.2 Contra-indications and associated precautions
        10.2.3 Human factors considerations
Annexes
A - Rationale for the development and provisions of this
    technical information report
B - Example environmental testing matrix
C - Bibliography

Gives guidelines for gathering data and information to demonstrate the safety and effectiveness of ventricular assist and heart replacement systems for patients with heart dysfunction.

Committee
MC
DocumentType
Standard
Pages
27
PublisherName
Association for the Advancement of Medical Instrumentation
Status
Superseded
SupersededBy

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
£57.04
Excluding VAT