• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS 1023.3-1973

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Low voltage switchgear and controlgear - Thermal protection of electric motors - Inherent overheat protectors

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

01-01-1973

Superseded date

30-06-2017

Superseded by

AS 60947.8-2005

£21.70
Excluding VAT
Summarise this standard

1 - AS 1023.3-1973 THERMAL PROTECTION OF ELECTRIC MOTORS - INHERENT OVERHEAT PROTECTORS - METRIC UNITS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1. SCOPE AND GENERAL
6 - 1.1 SCOPE.
6 - 1.2 SAFETY REQUIREMENTS.
6 - 1.3 DEFlNlTIONS.
6 - 1.3.1 Inherent Overheat Protector
6 - 1.3.2 Overheating
6 - 1.3.3 First Cycle Trip Time
7 - 1.4 CLASSIFlCATlON.
7 - SECTION 2. CHARACTERISTICS
7 - 2.1 CHARACTERISTICS OF PROTECTORS.
8 - SECTION 3. MARKING
8 - 3.1 MOTOR NAMEPLATE.
8 - 3.2 PROTECTOR MARKING.
8 - SECTlON 4. STANDARD CONDITIONS FOR OPERATION
8 - 4.1 NOMINAL OPERATING TEMPERATURE.
8 - 4.2 NOMINAL RESETTlNG TEMPERATURE.
8 - 4.3 FIRST-CYCLE TRIP TIME.
9 - SECTION 5. STANDARD CONDITIONS FOR CONSTRUCTION
9 - 5.1 GENERAL.
9 - 5.1.1 Construction.
9 - 5.1.2 Tripping.
9 - 5.1.3 Calibration.
9 - 5.1.4 Resetting.
9 - 5.1.5 Corrosion Resistance.
9 - 5.1.6 Ability to Withstand Motor Manufacturing Processes.
9 - 5.1.7 External Control Circuit.
9 - 5.2 SPACINGS.
9 - 5.2.1 Connections in Motor Circuit.
10 - 5.2.2 Connections in External Control Circuit.
10 - 5.2.3 Separate Motor Protector Control Circuit and Motor.
10 - 5.2.4 Separate Motor Protector Control Circuits.
11 - SECTION 6. TESTING
11 - 6.1 TESTS.
11 - 6.1.1 General.
11 - 6.1.2 Type Tests.
11 - 6.1.3 Routine Tests.
11 - 6.2 RATED CONDITIONS.
11 - 6.2.1 Test Voltage.
11 - 6.2.2 Ambient Temperatures.
11 - 6.3 TYPE TESTS.
11 - 6.3.1 General.
11 - 6.3.2 Tests on Protectors.
12 - 6.3.3 Tests on Combination of Protector and Motor.
16 - 6.4 ROUTINE TESTS.
16 - 6.4.1 General.
16 - 6.4.2 High Voltage Test.
17 - APPENDIX A - USER DATA REQUIRED FOR APPLICATION OF INHERENT OVERHEAT PROTECTORS ON SINGLE- PHASE A. C. MOTORS
17 - A1 MOTOR DATA.
17 - A2 PROTECTOR LOCATION.
17 - A3 TEST DATA.
17 - A3. 1 Temperature.
17 - A3. 2 Locked Rotor Test.
18 - A3. 3 Running Overload Tests.
18 - A4 TYPlCAL SET OF DATA.

Applies to automatically or manually reset devices for use with a.c. motors having a rated output of 11 kW or less, and suitable for connection in an external circuit not exceeding 600 V for motors having a rated voltage not exceeding 3300 V, or in the motor circuit for motors having a rated voltage not exceeding 600 V. Tests for electrical properties, mechanical endurance, temperature rise and fire hazard are prescribed.

Committee
EL-006
DocumentType
Standard
ISBN
0 7262 4713 8
Pages
13
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This specification applies to inherent overheat protectors, built into a.c. motors, together with their control units, forming part of a system of thermal protection of motors. They may be:(a) Connected in an external circuit of rated voltage not exceeding 600 V, of motors having a rated voltage not exceeding 3300 V and a rated output not exceeding 11 kW.(b) Connected in the motor circuit, the motor associated with the device having a rated voltage not exceeding 600 V and a rated output not exceeding 11 kW. The protectors may be automatically reset or manually reset.The protectors are responsive to motor heat alone or to a combination of motor heat plus the motor current passing through the device. This specification does not apply to inherent overheat protectors associated with sealed (hermetic) type compressor motors.NOTE: Appendix A sets out user data required for the application of inherent overheat protectors on single phase a.c. motors.

Reconfirmed 1984

⚠

A newer version of this standard is available.

View Current Edition
£21.70
Excluding VAT