• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1289.3.1.1-2009

Current

Current

The latest, up-to-date edition.

Methods of testing soils for engineering purposes Soil classification tests - Determination of the liquid limit of a soil - Four point Casagrande method

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

17-03-2017

£27.49
Excluding VAT

This Standard sets out a method for determining the liquid limit of soil (the moisture content at which a soil passes) from the plastic to the liquid state).

Committee
CE-009
DocumentType
Standard
ISBN
0 7337 9066 6
Pages
7
ProductNote
Reconfirmed 17/03/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 17/03/2017
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out a method for determining the liquid limit of soil (the moisture content at which a soil passes) from the plastic to the liquid state).

First published as AS A89.2A-1966.
Revised and redesignated as AS 1289.C1.1-1977.
Revised and redesignated as AS 1289.3.1.1-1995.
Second edition 2009.
Reissued incorporating Amendment No. 1 (October 2015).

AS 1683.15.2-1990 Methods of test for elastomers Durometer hardness
AS 1289.2.1.1-2005 Methods of testing soils for engineering purposes Soil moisture content tests - Determination of the moisture content of a soil - Oven drying method (standard method) (Reconfirmed 2016)
AS 1289.1.1-2001 Methods of testing soils for engineering purposes Sampling and preparation of soils - Preparation of disturbed soil samples for testing

AS 1289.3.1.2-2009 Methods of testing soils for engineering purposes Soil classification tests - Determination of the liquid limit of a soil - One point Casagrande method (subsidiary method) (Reconfirmed 2017)
AS 1597.2-2013 Precast reinforced concrete box culverts Large culverts (exceeding 1200 mm span or 1200 mm height and up to and including 4200 mm span and 4200 mm height)
AS 1289.5.2.1:2017 Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using modified compactive effort
AS 1289.5.1.1:2017 Methods of testing soils for engineering purposes Soil compaction and density tests - Determination of the dry density/moisture content relation of a soil using standard compactive effort
AS 3727.1:2016 Pavements Residential

£27.49