1 - AS 1670.1-2004 FIRE DETECTION, WARNING, CONTROL AND INTERCOM SYSTEMS-SYSTEM DESIGN, INSTALLATIO AND COMMISSIONING - PART 1: F
4 - PREFACE
6 - CONTENTS
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 APPLICATION
8 - 1.3 REFERENCED DOCUMENTS
10 - 1.4 DEFINITIONS
10 - 1.4.1 Adjacent
10 - 1.4.2 Alarm acknowledgment facility
10 - 1.4.3 Alarm signalling equipment
10 - 1.4.4 Alarm verification facility
10 - 1.4.5 Approval (approved)
10 - 1.4.6 Contiguous
10 - 1.4.7 Corridor
10 - 1.4.8 Cupboard
10 - 1.4.9 Designated building entry point
10 - 1.4.10 Designated site entry point
10 - 1.4.11 Distributed system
10 - 1.4.12 Extra-low voltage
11 - 1.4.13 Fire dispatch centre
11 - 1.4.14 Level surface
11 - 1.4.15 Low voltage
11 - 1.4.16 Monitoring service provider
11 - 1.4.17 Multi-sensor detector
11 - 1.4.18 Occupied area
11 - 1.4.19 Power supply
11 - 1.4.20 Protected area
11 - 1.4.21 Protected building
11 - 1.4.22 Separate cable path
11 - 1.4.23 Site
11 - 1.4.24 Sloping surface
11 - 1.4.25 Sole occupancy unit
11 - 1.4.26 Supervised
12 - 1.5 INTERPRETATION OF SPECIFIED LIMITING VALUES
13 - SECTION 2 SYSTEM CONFIGURATION
13 - 2.1 COMPONENTS
14 - 2.2 SEPARATION OF SYSTEMS
14 - 2.3 DESIGNATED ENTRY POINT
14 - 2.3.1 Designated building entry point
15 - 2.3.2 Designated site entry point
15 - 2.4 ALARM ZONE LIMITATIONS
17 - 2.5 ADDRESSABLE CIRCUITS
18 - 2.6 DISTRIBUTED SYSTEMS
18 - 2.6.1 Subindicator panels
18 - 2.6.2 Distributed parts of CIE
19 - 2.6.3 Signal path fault indication
20 - 2.6.4 Signal path protection
21 - SECTION 3 INSTALLATION REQUIREMENTS
21 - 3.1 GENERAL
21 - 3.2 ALARM ACKNOWLEDGMENT FACILITY
21 - 3.3 DEPENDENCY ON MORE THAN ONE ALARM SIGNAL (ALARM VERIFICATION FACILITY)
22 - 3.4 ALTERATIONS TO EXISTING INSTALLATIONS
22 - 3.5 MULTI-POINT ASPIRATING SMOKE DETECTORS
23 - 3.6 CONTROL OF ANCILLARY DEVICES
23 - 3.6.1 General
23 - 3.6.2 Fire suppression system activation
23 - 3.7 DETECTOR ALARM INDICATION
24 - 3.8 EXTERNAL ALARM INDICATION
24 - 3.9 FIRE INDICATOR PANEL
24 - 3.9.1 General
24 - 3.9.2 Covering door
24 - 3.9.3 Remote location
24 - 3.9.4 Clearance
25 - 3.10 ZONE BLOCK PLAN
25 - 3.11 CO FIRE DETECTOR LABELLING
25 - 3.12 FIRE SUPPRESSION SYSTEM
26 - 3.13 FLOW/PRESSURE SWITCHES
26 - 3.14 INTERMIXING OF ACTUATING DEVICES
26 - 3.15 MANUAL CALL POINTS
26 - 3.16 POWER SOURCES
26 - 3.16.1 Primary power source
26 - 3.16.2 Secondary power source
26 - 3.16.3 Power source rating
27 - 3.16.4 Battery capacity
28 - 3.16.5 Batteries and enclosure
28 - 3.16.6 Ancillary loads
28 - 3.17 REMOTE INDICATORS FOR FIRE DETECTORS
28 - 3.18 REMOTE MONITORING
28 - 3.18.1 General
28 - 3.18.2 Alarm signalling equipment
29 - 3.18.3 Connection
29 - 3.19 SMOKE AND FIRE DOOR RELEASE CONTROL
29 - 3.20 SUBINDICATOR PANEL (SIP)
29 - 3.21 VALVE MONITORING DEVICES
29 - 3.22 OCCUPANT WARNING
30 - 3.23 WIRE-FREE ALARM ZONE CIRCUITS
30 - 3.24 WIRING
30 - 3.24.1 General
31 - 3.24.2 Telecommunications-type cables
31 - 3.24.3 Conductors
31 - 3.24.4 Cable colour
31 - 3.24.5 Terminations
32 - 3.24.6 Joints
32 - 3.25 LOCATION OF DETECTORS
32 - 3.25.1 General
33 - 3.25.2 Accessible service tunnels
33 - 3.25.3 Air-handling systems
33 - 3.25.4 Concealed spaces
33 - 3.25.4.1 General
34 - 3.25.4.2 Electrical equipment
34 - 3.25.4.3 Remote indicators for fire detectors
34 - 3.25.5 Cupboards
34 - 3.25.6 Intermediate horizontal surfaces
34 - 3.25.7 Open grid ceilings
35 - 3.25.8 Restricted fire service access
35 - 3.25.9 Sole occupancy units
35 - 3.25.10 Stairwells
35 - 3.25.11 Transportable enclosures
35 - 3.25.12 Vertical shafts and openings
36 - 3.26 LOCATIONS WHERE DETECTORS ARE NOT REQUIRED
36 - 3.27 FIRE BRIGADE PANEL
37 - 3.28 MULTI-SENSOR DETECTORS
38 - SECTION 4 HEAT DETECTORS
38 - 4.1 SPACING AND LOCATION OF POINT-TYPE HEAT DETECTORS
38 - 4.1.1 General
38 - 4.1.2 Spacing between detectors for level surfaces
39 - 4.1.3 Spacing of detectors for sloping surfaces
39 - 4.1.4 Spacing from walls, partitions, or air supply openings
39 - 4.1.5 Reduced spacing
39 - 4.1.6 Spacing in concealed spaces requiring protection
39 - 4.2 LINEAR HEAT DETECTORS
44 - SECTION 5 SMOKE AND CO FIRE DETECTORS
44 - 5.1 SPACING AND LOCATION OF POINT-TYPE DETECTORS
44 - 5.1.1 General
44 - 5.1.2 Spacing between detectors for level surfaces
45 - 5.1.3 Spacing between detectors for sloping surfaces
45 - 5.1.4 Spacing from walls, partitions, or air supply openings
46 - 5.1.5 Areas of high airflows
46 - 5.1.6 Location of detectors on level surfaces with deep beams
47 - 5.1.7 Spacing in concealed spaces requiring protection
47 - 5.2 MULTI-POINT ASPIRATING SMOKE DETECTORS
47 - 5.2.1 General
47 - 5.2.2 System design
53 - SECTION 6 FLAME DETECTORS
53 - 6.1 LOCATION
53 - 6.2 SPACING
54 - SECTION 7 COMMISSIONING
54 - 7.1 GENERAL
56 - 7.2 DOCUMENTATION
57 - 7.3 LOG
58 - APPENDIX A - GUIDANCE FOR THE SELECTION OF DETECTORS
58 - A1 INTRODUCTION
58 - A2 GENERAL NOTES ON DETECTORS
59 - A3 HEAT DETECTORS OR HEAT ALARMS
59 - A3.1 General
60 - A3.2 Application
61 - A4 SMOKE DETECTORS OR SMOKE ALARMS
61 - A4.1 General
62 - A4.2 Application
62 - A4.2.1 General
62 - A4.2.2 Location considerations
63 - A4.2.3 Ceiling surfaces
63 - A4.2.4 Stratification
63 - A4.2.5 Airflow
63 - A4.2.6 Ducts
64 - A4.2.7 Special considerations
64 - A5 MULTI-SENSOR DETECTORS
64 - A6 ASPIRATING SMOKE DETECTORS
64 - A6.1 General
64 - A6.2 Detector principles
64 - A6.2.1 General
65 - A6.2.2 Light scatter
65 - A6.2.3 Particle counting
65 - A6.3 Types
65 - A6.3.1 General
65 - A6.3.2 Very high sensitivity (typically for up to 2000 m 2 )
65 - A6.3.3 Normal sensitivity (typically for a similar coverage of a single point detector)
65 - A6.4 Pipe network and aggregation
66 - A6.5 Flow sensing
66 - A6.6 Dust filters detection and rejection
66 - A6.7 Applications
67 - A7 CARBON MONOXIDE FIRE DETECTORS
67 - A7.1 General
67 - A7.2 Application
67 - A7.2.1 General
68 - A7.2.2 Stratification
68 - A7.2.3 Airflow
68 - A7.2.4 Ducts
68 - A7.2.5 Special considerations
68 - A8 FLAME DETECTORS
68 - A8.1 General
69 - A8.2 Radiation sources and inhibitors
69 - A8.2.1 General
69 - A8.2.2 Radiation sources
70 - A8.2.3 Radiation inhibitors
70 - A8.3 Ultraviolet flame detection techniques
70 - A8.3.1 Detection principles
70 - A8.3.2 Advantages
71 - A8.3.3 Limitations
71 - A8.4 Single-channel infra-red detectors
71 - A8.4.1 Detection principles
71 - A8.4.2 Advantages
72 - A8.4.3 Limitations
72 - A8.5 Ultraviolet/infra-red (single-channel) flame detectors
72 - A8.5.1 Detection principles
72 - A8.5.2 Advantage
72 - A8.5.3 Limitations
73 - A8.6 Dual-channel infra-red flame detectors
73 - A8.6.1 Detection principles
73 - A8.6.2 Advantages
73 - A8.6.3 Limitations
74 - A8.7 Triple-channel infra-red flame detectors
74 - A8.7.1 Detection principles
74 - A8.7.2 Advantages
75 - A8.7.3 Limitations
76 - APPENDIX B - FIRE RATED WIRING SYSTEMS
76 - B1 PROTECTION AGAINST EXPOSURE TO FIRE
76 - B2 PROTECTION AGAINST MECHANICAL DAMAGE
76 - B2.1 General
76 - B2.2 WSXX
76 - B2.3 WSX1
76 - B2.4 WSX2
77 - B2.5 WSX3
77 - B2.6 WSX4
77 - B2.7 WSX5
77 - B3 PROTECTION AGAINST HOSING WITH WATER
78 - APPENDIX C - EXAMPLES OF POWER SOURCE CAPACITY CALCULATIONS
78 - C1 BATTERY CAPACITY CALCULATIONS
78 - C1.1 Typical IQ calculation
79 - C1.2 Typical IA calculation
79 - C2 PRIMARY POWER SOURCE CALCULATIONS
79 - C2.1 Battery charger current calculation
80 - C2.2 Power supply requirement
81 - APPENDIX D - FIRE ALARM SYMBOLS
83 - APPENDIX E - COMMISSIONING TEST REPORT
87 - APPENDIX F - STANDARD FORM OF INSTALLERS STATEMENT FOR FIRE ALARM SYSTEM