• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1684.2 N1/N2 Supp 11-2010

Current

Current

The latest, up-to-date edition.

Residential timber-framed construction Non-cyclonic areas, N1/N2 Supplement 11: Timber framing span tables - Wind classification N1/N2 - Unseasoned softwood - Stress Grade F7 (Supplement to AS 1684.2-2010) (Reconfirmed 2024)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-06-2010

£6.06
Excluding VAT

1 - F7 Unseasoned Softwood
5 - [1-32] Single or Upper Storey
5 - [1-5] Floor Bearers
5 - [1] Supporting single or upper storey loadbearing walls - FLW 1200
6 - [2] Supporting single or upper storey loadbearing walls - FLW 2400
7 - [3] Supporting single or upper storey loadbearing walls - FLW 3600
8 - [4] Supporting single or upper storey loadbearing walls - FLW 4800
9 - [5] Supporting floor load only
10 - [6] Floor Joists
12 - [7-13] Wall Studs
12 - [7] Wall studs - Not notched single or upper storey
13 - [8] Wall studs - Notched 20mm single or upper storey
15 - [9] Studs supporting concentrated loads - Not notched
15 - [10] Studs supporting concentrated loads - Notched to 20mm
16 - [11] Jamb studs - Single or upper storey
18 - [12] Internal loadbearing wall studs - Not notched single or upper storey
20 - [13] Internal loadbearing wall studs - Notched to 20mm single or upper storey
22 - [14-16] Plates
22 - [14] Bottom Plates - Supporting single or upper storey
23 - [15] Top Plates - Single or upper storey sheet roof
24 - [16] Top Plates - Single or upper storey tile roof
25 - [17-20] Lintels
25 - [17] Sheet roof - Single or upper storey load bearing walls
26 - [18] Tile roof - Single or upper storey load bearing walls
27 - [19] Sheet roof - Supporting concentrated roof loads
28 - [20] Tile roof - Supporting concentrated roof loads
29 - [21-22] Ceiling Joists
29 - [21] Supporting ceiling loads, no over batten
29 - [22] Supporting ceiling loads, with over batten
30 - [23] Hanging Beams - Supporting ceiling loads
30 - [24] Counter Beams
31 - [25] Strutting/Hanging Beams - Supporting roof and ceiling loads
32 - [26] Strutting/Counter Beams - Supporting root and ceiling loads
32 - [27] Strutting Beams
33 - [28] Underpurlins
34 - [29] Rafters or Purlins
36 - [30-31] Ridge or Intermediate Beams
36 - [30] Single span
38 - [31] Continuous span
40 - [32] Roof Battens - Supporting roofing only
41 - [33-48] Lower Storey of Two Storey
41 - [33-35] Floor Bearers
41 - [33] Supporting two storey loadbearing walls - FLW 1800
42 - [34] Supporting two storey loadbearing walls - FLW 3600
43 - [35] Lower storey of two storey - Supporting upper and lower floor loads only
44 - [36-44] Wall Studs
44 - [36] Wall studs - Not notched lower storey loadbearing walls
45 - [37] Wall studs - Notched to 20mm lower storey loadbearing walls
46 - [38] Studs - Not notched - Supporting concentrated floor loads
46 - [39] Studs - Notched to 20mm - Supporting concentrated floor loads
47 - [40] Jamb studs - Lower storey of two storey - FLW 1800
48 - [41] Jamb studs - Lower storey of two storey - FLW 3600
49 - [42] Jamb studs - Lower storey of two storey - FLW 4800
50 - [43] Wall studs - Not notched supporting floor loads only
50 - [44] Wall studs - Notched to 20mm supporting floor loads only
51 - [45-46] Plates
51 - [45] Bottom plates - Lower storey of two storey
52 - [46] Top plates - Lower storey of two storey
53 - [47-48] Lintels
53 - [47] Lower storey loadbearing walls - Sheet roof
54 - [48] Lower storey loadbearing walls - Tile roof
55 - [49-53] Verandahs, Posts and Decks
55 - [49] Deck Bearers
55 - [50] Deck Joists
56 - [51A-52A] Verandahs Beams
56 - [51A] Single span
58 - [52A] Continuous span
60 - [53] Posts Supporting and/or Floor Loads

This is a Supplement to AS 1684.2-2010 and AS 1684.2:2021; Residential timber-framed construction - Part 2: Non-cyclonic areas. The Supplement provides timber framing span tables for wind classification N1/N2 for unseasoned softwood - Stress Grade F7.

Committee
TM-002
DocumentType
Supplement (Main)
ISBN
978 0 7337 9501 5
Pages
56
PublisherName
Standards Australia
Status
Current
SupersededBy
Supersedes

Originated as AS 1684 Supp 3-1975.
Second edition 1992.
Revised and redesignated as AS 1684.2 N1/N2 Supp 11-1999.
Third edition 2006.
Fourth edition 2010.

AS 4654.2-2012 Waterproofing membranes for external above-ground use Design and installation
AS/NZS 1748.1:2011 Timber - Solid - Stress-graded for structural purposes General requirements
AS 4773.2-2010 Masonry in small buildings - Construction
AS 4773.1-2010 Masonry in small buildings Design
AS 1884-2012 Floor coverings - Resilient sheet and tiles - Installation practices
AS 3818.8-2010 Timber - Heavy structural products - Visually graded Stumps and sole plates

£6.06
Excluding VAT