Residential timber-framed construction - Non-cyclonic areas - N1/N2 Supplement 12: Timber framing span tables - Wind classification N1/N2 - Unseasoned hardwood - Stress grade F8 (Supplement to AS 1684.2-1999)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

30-06-2017

Language(s)

English

Published date

01-01-1999

Preview

1 - AS 1684.2 N1/N2 Supp12 - 1999
3 - LIST OF TABLES
4 - [1-32] Single or Upper Storey
4 - [1-5] Floor Bearers
4 - [1] Supporting single or upper storey loadbearing walls - FLW 1200
5 - [2] Supporting single or upper storey loadbearing walls - FLW 2400
6 - [3] Supporting single or upper storey loadbearing walls - FLW 3600
7 - [4] Supporting single or upper storey loadbearing walls - FLW 4800
8 - [5] Supporting floor load only
9 - [6] Floor Joists
11 - [7-13] Wall Studs
11 - [7] Wall studs - Not notched single or upper storey
12 - [8] Wall studs - Notched 20mm single or upper storey
14 - [9] Studs supporting concentrated loads - Not notched
14 - [10] Studs supporting concentrated loads - Notched to 20mm
15 - [11] Jamb studs - Single or upper storey
17 - [12] Internal loadbearing wall studs - Not notched single or upper storey
18 - [13] Internal loadbearing wall studs - Notched to 20mm single or upper storey
20 - [14-16] Plates
20 - [14] Bottom Plates - Supporting single or upper storey
21 - [15] Top Plates - Single or upper storey sheet roof
22 - [16] Top Plates - Single or upper storey tile roof
23 - [17-20] Lintels
23 - [17] Sheet roof - Single or upper storey load bearing walls
24 - [18] Tile roof - Single or upper storey load bearing walls
25 - [19] Sheet roof - Supporting concentrated roof loads
26 - [20] Tile roof - Supporting concentrated roof loads
27 - [21-22] Ceiling Joists
27 - [21] Supporting ceiling loads, no over batten
27 - [22] Supporting ceiling loads, with over batten
28 - [23] Hanging Beams - Supporting ceiling loads
28 - [24] Counter Beams
29 - [25] Strutting/Hanging Beams - Supporting roof and ceiling loads
30 - [26] Strutting/Counter Beams - Supporting root and ceiling loads
30 - [27] Strutting Beams
31 - [28] Underpurlins
32 - [29] Rafters or Purlins
34 - [30-31] Ridge or Intermediate Beams
34 - [30] Single span
36 - [31] Continuous span
38 - [32] Roof Battens - Supporting roofing only
39 - [33-48] Lower Storey of Two Storey
39 - [33-35] Floor Bearers
39 - [33] Supporting two storey loadbearing walls - FLW 1800
40 - [34] Supporting two storey loadbearing walls - FLW 3600
41 - [35] Lower storey of two storey - Supporting upper and lower floor loads only
42 - [36-44] Wall Studs
42 - [36] Wall studs - Not notched lower storey loadbearing walls
43 - [37] Wall studs - Notched to 20mm lower storey loadbearing walls
44 - [38] Studs - Not notched - Supporting concentrated floor loads
44 - [39] Studs - Notched to 20mm - Supporting concentrated floor loads
45 - [40] Jamb studs - Lower storey of two storey - FLW 1800
46 - [41] Jamb studs - Lower storey of two storey - FLW 3600
47 - [42] Jamb studs - Lower storey of two storey - FLW 4800
48 - [43] Wall studs - Not notched supporting floor loads only
48 - [44] Wall studs - Notched to 20mm supporting floor loads only
49 - [45-46] Plates
49 - [45] Bottom plates - Lower storey of two storey
50 - [46] Top plates - Lower storey of two storey
51 - [47-48] Lintels
51 - [47] Lower storey loadbearing walls - Sheet roof
52 - [48] Lower storey loadbearing walls - Tile roof
53 - [49-53] Verandahs, Posts and Decks
53 - [49] Deck Bearers
53 - [50] Deck Joists
54 - [51A-52] Verandahs Beams
54 - [51A] Single span
56 - [52] Continuous span
58 - [53] Posts Supporting and/or Floor Loads

Committee
TM-002
DocumentType
Supplement (Main)
ISBN
0 7337 3105 8
Pages
55
ProductNote
Incorporates Amendment 1 published April 2000, Amdt 2 published 21. July 2000, Amdt 3 published 27 July 2001 and Amdt 4 published 3. September 2002.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

First published as AS 1684 Supp 4-1975.Second edition 1992.Revised and redesignated as AS 1684.2 N1/N2 Supplement 12-1999. First published as AS 1684 Supp 4-1975. Second edition 1992. Revised and redesignated as AS 1684.2 N1/N2 Supplement 12-1999.

View more information
£6.29
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.