• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 1684.2 N1/N2 Supp 2-2010

Current

Current

The latest, up-to-date edition.

Residential timber-framed construction Non-cyclonic areas, N1/N2 Supplement 2: Timber framing span tables - Wind classification, N1/N2 - Seasoned softwood - Stress Grade F7 (Supplement to AS 1684.2-2010) (Reconfirmed 2024)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

21-06-2010

£6.06
Excluding VAT

1 - F7 Seasoned Softwood
5 - [1-32] Single or Upper Storey
5 - [1-5] Floor Bearers
5 - [1] Supporting single or upper storey loadbearing walls - FLW 1200
6 - [2] Supporting single or upper storey loadbearing walls - FLW 2400
7 - [3] Supporting single or upper storey loadbearing walls - FLW 3600
8 - [4] Supporting single or upper storey loadbearing walls - FLW 4800
9 - [5] Supporting floor load only
10 - [6] Floor Joists
11 - [7-13] Wall Studs
11 - [7] Wall studs - Not notched single or upper storey
12 - [8] Wall studs - Notched 20mm single or upper storey
13 - [9] Studs supporting concentrated loads - Not notched
13 - [10] Studs supporting concentrated loads - Notched to 20mm
14 - [11] Jamb studs - Single or upper storey
16 - [12] Internal loadbearing wall studs - Not notched single or upper storey
17 - [13] Internal loadbearing wall studs - Notched to 20mm single or upper storey
19 - [14-16] Plates
19 - [14] Bottom Plates - Supporting single or upper storey
20 - [15] Top Plates - Single or upper storey sheet roof
21 - [16] Top Plates - Single or upper storey tile roof
22 - [17-20] Lintels
22 - [17] Sheet roof - Single or upper storey load bearing walls
23 - [18] Tile roof - Single or upper storey load bearing walls
24 - [19] Sheet roof - Supporting concentrated roof loads
25 - [20] Tile roof - Supporting concentrated roof loads
26 - [21-22] Ceiling Joists
26 - [21] Supporting ceiling loads, no over batten
26 - [22] Supporting ceiling loads, with over batten
27 - [23] Hanging Beams - Supporting ceiling loads
27 - [24] Counter Beams
28 - [25] Strutting/Hanging Beams - Supporting roof and ceiling loads
29 - [26] Strutting/Counter Beams - Supporting root and ceiling loads
29 - [27] Strutting Beams
30 - [28] Underpurlins
31 - [29] Rafters or Purlins
33 - [30-31] Ridge or Intermediate Beams
33 - [30] Single span
35 - [31] Continuous span
37 - [32] Roof Battens - Supporting roofing only
38 - [33-48] Lower Storey of Two Storey
38 - [33-35] Floor Bearers
38 - [33] Supporting two storey loadbearing walls - FLW 1800
39 - [34] Supporting two storey loadbearing walls - FLW 3600
40 - [35] Lower storey of two storey - Supporting upper and lower floor loads only
41 - [36-44] Wall Studs
41 - [36] Wall studs - Not notched lower storey loadbearing walls
42 - [37] Wall studs - Notched to 20mm lower storey loadbearing walls
43 - [38] Studs - Not notched - Supporting concentrated floor loads
43 - [39] Studs - Notched to 20mm - Supporting concentrated floor loads
44 - [40] Jamb studs - Lower storey of two storey - FLW 1800
45 - [41] Jamb studs - Lower storey of two storey - FLW 3600
46 - [42] Jamb studs - Lower storey of two storey - FLW 4800
47 - [43] Wall studs - Not notched supporting floor loads only
47 - [44] Wall studs - Notched to 20mm supporting floor loads only
48 - [45-46] Plates
48 - [45] Bottom plates - Lower storey of two storey
49 - [46] Top plates - Lower storey of two storey
50 - [47-48] Lintels
50 - [47] Lower storey loadbearing walls - Sheet roof
51 - [48] Lower storey loadbearing walls - Tile roof
52 - [49-53] Verandahs, Posts and Decks
52 - [49] Deck Bearers
52 - [50] Deck Joists
53 - [51A-52A] Verandahs Beams
53 - [51A] Single span
55 - [52A] Continuous span
57 - [53] Posts Supporting and/or Floor Loads

This is a Supplement to AS 1684.2-2010 and AS 1684.2:2021; Residential timber-framed construction - Part 2: Non-cyclonic areas. The Supplement provides timber framing span tables for wind classification N1/N2 for seasoned softwood - Stress Grade F7.

Committee
TM-002
DocumentType
Supplement (Main)
ISBN
978 0 7337 9492 6
Pages
56
PublisherName
Standards Australia
Status
Current
SupersededBy
Supersedes

Originated as AS 1684 Supp 10-1975.
Second edition 1992.
Revised and redesignated as AS 1684.2 N1/N2 Supp 2-1999.
Third edition 2006.
Fourth edition 2010.

AS 4654.2-2012 Waterproofing membranes for external above-ground use Design and installation
AS/NZS 1748.1:2011 Timber - Solid - Stress-graded for structural purposes General requirements
AS 4773.2-2010 Masonry in small buildings - Construction
AS 4773.1-2010 Masonry in small buildings Design
AS 1884-2012 Floor coverings - Resilient sheet and tiles - Installation practices
AS 3818.8-2010 Timber - Heavy structural products - Visually graded Stumps and sole plates

£6.06
Excluding VAT