AS 1824.1-1995

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Insulation co-ordination Definitions, principles and rules

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

05-03-1995

Superseded date

23-09-2024

Superseded by

AS 60071.1:2024

£51.67
Excluding VAT
Summarise this standard

Specifies the procedure for the selection of the standard withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installation of three-phase a.c. systems having a highest voltage for equipment above 1 kV. It also lists the standardized values from which the standard withstand voltages shall be selected. This Standard is technically equivalent to and has been reproduced from IEC 71-1:1993.

Committee
EL-007
DocumentType
Standard
ISBN
0 7262 9571 X
Pages
21
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This part of International Standard IEC 71 applies to three-phase a.c. systems having a highest voltage for equipment above 1 kV. It specifies the procedure for the selection of the standard withstand voltages for the phase-to-earth, phase-to-phase and longitudinal insulation of the equipment and the installations of these systems. It also gives the lists of the standardized values from which the standard withstand voltages shall be selected. This part recommends that the selected withstand voltages should be associated with the highest voltage for equipment. This association is for insulation co-ordination purposes only. The requirements for human safety are not covered by this Standard. Although the principles of this part also apply to transmission line insulation, the values of the withstand voltages may be different from the standard withstand voltages.The apparatus committees are responsible for specifying the withstand voltages and the test procedures suitable for the relevant equipment taking into consideration the recommendations of this Standard.NOTE û In IEC 71-2 Application Guide, (under revision), all rules for insulation co-ordination given in this Standard are justified in detail, in particular the association of the standard withstand voltages with the highest voltage for equipment. When more than one set of standard withstand voltages is associated with the same highest voltage for equipment, guidance is provided for the selection of the most suitable set.

Standards Relationship
IEC 60071-3:1982 Identical
IEC 60071-1:1993 Identical

First published as AS C337-1963.
Revised and redesignated AS 1824.1-1976.
Second edition 1985.
Third edition 1995.

⚠

A newer version of this standard is available.

View Current Edition