AS 2050-2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Installation of roof tiles
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-01-2002
08-07-2024
Sets out requirements for the placement and installing of roof tiles of the types specified in AS 2049. The installing methods described in This Standard apply only to tiled roofs of buildings that are intended for domestic, commercial or light industrial purposes for wind classifications N1-N4 and C1-C3 inclusive. This Standard applies only to roofs with pitches of 15 degrees or greater.
| Committee |
BD-008
|
| DocumentType |
Standard
|
| Pages |
20
|
| ProductNote |
Content within this standard has been reproduced (with modification) from the NASH Standard – Residential and Low-rise Steel Framing Part 2: Design Solutions, 2014 (incorporating amendment A), with permission of NASH. The NASH content which is reproduced in AS 2050 as Table 2.2.2 (B), Figure 2.2.2 and Table 3.2.6 may not be copied, reprinted or sub-licenced to end users.
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This Standard sets out requirements for the placement and installing of roof tiles of the types specified in AS 2049. The installation methods described in this Standard apply only to tiled roofs of buildings that are intended for domestic, commercial or light industrial purposes for wind classifications N1-N4 and C1-C3 inclusive. This Standard applies only to roofs with a pitch of 15° or greater. NOTES: 1 This Standard does not restrict the use of other installing and fastening methods or materials where it can be shown that they are not inferior to the performance achieved by the materials and methods described herein. 2 Where it is intended to install tiles to roofs with a pitch of less than 15°, the tile manufacturer’s advice should be sought to determine weatherproofing requirements. 3 The type of roof construction described in this Standard may not be adequate to resist wind forces in cases where the height of the eaves is more than 15 m above the mean surrounding ground level. In such cases, or in areas where cyclones or high winds are known to occur, the installing and fastening methods and sarking recommendations given in Appendix A are recommended.4 Appendix B includes information on the data normally provided by the specifier and the tile manufacturer, and on the work normally carried out as part of the tiling operation.
First published in part as AS CA5-1933.
AS CA6 first published 1933.
Second edition 1948.
Reprinted and redated AS CA6-1949.
Second edition AS CA5-1950.
Int 311 first published 1951.
Third edition AS CA5-1963.
Int 311-1951 revised and redesignated AS CA46-1967.
AS CA5-1963 revised and redesignated AS 2050-1977.
AS CA6-1949 revised and redesignated AS 1760-1975.
AS CA46-1967 revised and redesignated AS 1758-1975.
AS 1758-1975, AS 1760-1975 and AS 2050-1977 revised, amalgamated and redesignated AS 2050-1989.
Second edition 1995.
Fourth edition 2002.