AS 2430.1-1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Classification of hazardous areas - Explosive gas atmospheres
Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
01-01-1987
29-05-2024
Provides a classification of areas according to the likely existence of an explosive gas/air mixture, including areas in which the mixture is continuously present or present for long periods (Zone 0), areas in which the mixture is likely to occur in normal operation (Zone 1), and areas in which the mixture is not likely to occur or will exist for only a short time (Zone 2). Basic principles involved in classification are given and the factors to be considered in determining the type and extent of zones are described. Similar to IEC 79-10 in terminology, definitions and general treatment of the subject.
| Committee |
MS-011
|
| DocumentType |
Standard
|
| ISBN |
0 7262 4493 7
|
| Pages |
12
|
| PublisherName |
Standards Australia
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This standard provides guidance for the classification of hazardous areas according to the existence of or likelihood of the existence of an explosive gas/air mixture.NOTE: Areas classified as Zones 0, 1 or 2 in accordance with this standard are sometimes referred to as Class I areas.It applies to open and enclosed areas, in all above-ground situations, where there may be a risk due to the presence of flammable gas or vapour mixed with air under normal atmosphere conditions (see Note 1).This standard does not apply to -(a) underground workings including coal mining; (b) processing and manufacture of explosives;(c) areas which may be affected by oxygen enrichment;(d) areas where risks may arise due to the presence of combustible dusts (see Note 3); or(e) potential catastrophic failures such as the bursting of pressure vessels, pipelines or tanks.NOTES:1. Normal atmospheric conditions include variations above and below reference levels of 101.3 kPa and 20C provided the variations have a negligible effect on the explosion properties of the flammable materials.2. The design, construction and installation of plant and equipment have a significant bearing on classification. However, this standard does not specify any requirements for such design, construction or installation.3. The classification of hazardous areas where combustible dusts are present (Class II areas) is covered in AS 2430, Part 2.
| Standards | Relationship |
| IEC 60079-10:1972 | Identical |
Under revision See DR 99254