• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 3735-2001

Current

Current

Concrete structures for retaining liquids

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

13-03-2001

£49.90
Excluding VAT
Summarise this standard

1 - AS 3735-2001 CONCRETE STRUCTURES FOR RETAINING LIQUIDS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE AND APPLICATION
6 - 1.1.1 Scope
6 - 1.1.2 Application
7 - 1.2 REFERENCED DOCUMENTS
7 - 1.3 DEFINITIONS
7 - 1.4 NOTATION
8 - 1.5 USE OF ALTERNATIVE MATERIALS OR METHODS
8 - 1.5.1 General
9 - 1.5.2 Existing structures
9 - 1.5.3 Ferrocement
9 - 1.6 DRAWINGS AND SPECIFICATIONS
9 - 1.6.1 Design data
9 - 1.6.2 Design details
10 - SECTION 2 LOADS AND LOAD COMBINATIONS
10 - 2.1 GENERAL
10 - 2.2 LOADS AND OTHER ACTIONS
10 - 2.2.1 Temperature
11 - 2.2.2 Moisture variation
11 - 2.2.3 Earthquake
11 - 2.2.4 Other actions
12 - 2.3 STABILITY DESIGN
12 - 2.4 LOAD COMBINATIONS FOR SERVICEABILITY
13 - SECTION 3 DESIGN FOR SERVICEABILITY AND STRENGTH
13 - 3.1 GENERAL
13 - 3.2 REINFORCED CONCRETE
13 - 3.2.1 General
13 - 3.2.2 Minimum reinforcement ratio
14 - 3.2.3 Limiting steel stresses for serviceability
15 - 3.2.4 Limiting concrete thickness
15 - 3.3 PRESTRESSED CONCRETE
15 - 3.3.1 General
15 - 3.3.2 Analysis
15 - 3.3.3 Limiting concrete stresses for serviceability
15 - 3.3.4 Non-tensioned reinforcement
16 - 3.3.5 Partial prestressing
17 - SECTION 4 DESIGN FOR DURABILITY
17 - 4.1 GENERAL
17 - 4.2 EXPOSURE CLASSIFICATION
18 - 4.3 REQUIREMENTS FOR CONCRETE
18 - 4.4 REQUIREMENTS FOR COVER TO REINFORCEMENT (BARS AND TENDONS)
18 - 4.4.1 General
19 - 4.4.2 Cover for concrete placement
19 - 4.4.3 Cover for corrosion protection
20 - 4.4.4 Cover modifications for special circumstances
20 - 4.5 DURABILITY OF METAL FIXTURES IN CONTACT WITH CONCRETE
20 - 4.6 DURABILITY OF WATERSTOPS, SEALANTS AND OTHER ASSOCIATED ITEMS
21 - SECTION 5 MATERIAL AND CONSTRUCTION REQUIREMENTS
21 - 5.1 GENERAL
21 - 5.2 CONCRETE
21 - 5.2.1 General
21 - 5.2.2 Curing
21 - 5.2.3 Pneumatically applied concrete
21 - 5.3 REINFORCEMENT
21 - 5.3.1 Protective coating
21 - 5.3.2 Tendons
22 - SECTION 6 JOINTS, WATERSTOPS, JOINT FILLERS, AND SEALANTS
22 - 6.1 JOINTS
22 - 6.1.1 Purpose
22 - 6.1.2 Non-movement
22 - 6.1.3 Movement
23 - 6.2 WATERSTOPS
23 - 6.3 JOINT FILLERS
23 - 6.4 SEALANTS
23 - 6.5 CONTAMINATION OF WATER
24 - SECTION 7 TESTING
24 - 7.1 GENERAL
24 - 7.2 TESTING FOR LIQUID-TIGHTNESS
24 - 7.3 TESTING OF LIQUID-RETAINING STRUCTURES
24 - 7.4 TESTING OF ROOFS

Specifies requirements for the design and installation of reinforced concrete structures used for retaining liquids at ambient temperatures. This Standard is limited to concrete with ultimate compressive strength in the range 20 MPa to 50 MPa at 28 days. For these structures, This Standard supplements and takes precedence over the requirements of AS 3600, Concrete structures.

Committee
CE-022
DocumentType
Standard
ISBN
0 7337 3714 5
Pages
19
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies requirements for concrete structures and members that include reinforcing steel or tendons, or both, used for retaining liquids at ambient temperature.The Standard supplements and takes precedence over the requirements of AS 3600.The principles of concrete design and construction embodied in this Standard apply to structures and members made of concrete(a) with a characteristic compressive strength at 28 days (f c) in the range of 20 MPa to50 MPa; and(b) of saturated, surface-dry density in the range of 1800 kg/m3 to 2800 kg/m3. The Standard does not apply to the design of(i) dams;(ii) aqueducts, hydraulic tunnels or similar structures;(iii) small septic tanks (see AS 1546.1);(iv) portable precast concrete water tanks of less than 25 000 L capacity;(v) fibre-impregnated concrete that does not comply with the design requirements and procedures of AS 3600; or(vi) precast concrete pipes (pressure and non-pressure) (see AS 4058).

Originated as AS 3735-1991.
Second edition 2001.

Frequently Asked Questions

AS 3735 sets design and construction requirements for concrete structures used to retain liquids. It is an Australian standard published by Standards Australia.

AS 3735 is used by structural engineers and constructors of reservoirs, tanks and treatment structures. It is an Australian standard published by Standards Australia.

AS 3735 is Standards Australia's standard for concrete structures retaining liquids, while AS 3700 covers masonry structures (Australia). AS 3735 sets design and construction requirements for concrete structures used to retain liquids. AS 3700 sets requirements for the design and construction of masonry structures.

AS 3735 is listed in this catalog as an Australian standard published by Standards Australia, with its region recorded as Australia only. The catalog does not record a New Zealand adoption of this document.

AS 3735 sets design and construction requirements for concrete structures used to retain liquids. In practice it is applied by structural engineers and constructors of reservoirs, tanks and treatment structures.
£49.90
Excluding VAT