• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 4060-1992

Current

Current

Loads on buried vitrified clay pipes (Reconfirmed 2018)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

16-11-1992

£56.79
Excluding VAT
Summarise this standard

1 - AS 4060:1992 LOADS ON BURIED VITRIFIED CLAY PIPES
4 - PREFACE
4 - CONTENTS
5 - 1 SCOPE
5 - 2 APPLICATION
5 - 3 REFERENCED DOCUMENTS
5 - 4 DEFINITIONS
5 - 4.1 Bedding factor
5 - 4.2 Crushing strength class
5 - 4.3 Embedment
6 - 4.4 Existing surface
6 - 4.5 Fill
6 - 4.5.1 Coarse aggregate fill
6 - 4.5.2 Crusher waste fill
6 - 4.5.3 Embankment fill
6 - 4.5.4 Ordinary fill
6 - 4.5.5 Quarry waste fill
6 - 4.5.6 Select fill
6 - 4.5.7 Trench fill
6 - 4.6 Finished surface
6 - 4.7 Foundation
7 - 4.8 Installation condition
7 - 4.9 Internal pressure
7 - 4.10 Joint hole
7 - 4.11 Load
7 - 4.11.1 Superimposed load
7 - 4.11.2 Working load
7 - 4.12 Pipe length
7 - 4.13 Settlement ratio
8 - 5 NOTATION
9 - 6 WORKING LOADS
9 - 6.1 Types
9 - 6.2 Data
9 - 6.3 Working loads due to trench fill, embankment fill or in- situ material
9 - 6.3.1 General
9 - 6.3.2 Narrow trench condition
9 - 6.3.3 Wide trench or embankment condition (positive projection)
9 - 6.3.4 Embankment condition (negative projection)
10 - 6.3.5 Settlement ratio
11 - 6.3.6 Projection ratio
11 - 6.3.7 Multiple pipes
13 - 6.3.8 Jacked or bored pipes
13 - 6.4 Working loads due to superimposed dead loads
13 - 6.5 Working loads due to superimposed live loads
13 - 6.5.1 General
17 - 6.5.2 Superimposed live loads
18 - 7 INTERNAL WATER LOADS
19 - 8 COMPACTION
19 - 8.1 Degree of compaction
19 - 8.2 Measure of compaction
19 - 9 SUPPORT TYPES AND BEDDING FACTORS
19 - 9.1 Support types
19 - 9.1.1 General
19 - 9.1.2 Joint holes
20 - 9.1.3 Granular or concrete
22 - 9.1.4 Non-granular
22 - 9.2 Bedding factors
22 - 9.2.1 Granular or concrete
22 - 9.2.2 Non-granular
22 - 9.2.3 Jacked or bored pipes
22 - 10 DESIGN CRUSHING LOAD
22 - 11 SELECTION OF CRUSHING STRENGTH CLASS
24 - APPENDIX A - NON-GRANULAR SUPPORT TYPES
24 - A1 SCOPE
24 - A2 COMPACTION
24 - A3 SUPPORT TYPES AND BEDDING FACTORS
24 - A3.1 Support types
24 - A3.1.1 General
24 - A3.1.2 Joint holes
24 - A3.1.3 Type U support
24 - A3.1.4 Type H1 and Type H2 support
25 - A3.1.5 Type HS1 and Type HS2 support
26 - A3.2 Bedding factors
26 - A3.2.1 Values
26 - A3.2.2 Reduction of values
28 - APPENDIX B - EXTERNAL DIAMETER OF VITRIFIED CLAY PIPES
28 - B1 SCOPE

Specifies methods for calculating the working loads, resulting from overlaying material and superimposed dead and live loads, which act on buried vitrified clay pipelines. From these values, a design crushing load can be calculated for use in selecting an appropriate crushing strength class of pipes and fittings complying with AS1741, Vitrified clay pipes and fittings with flexible joints - Sewer quality.

Committee
WS/15
DocumentType
Standard
ISBN
0 7262 7733 9
Pages
24
ProductNote
Reconfirmed 21/09/2018.
This standard has been reconfirmed in Australia in 2018 and remains current in New Zealand. Reconfirmation Notice 21/09/2018
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard sets out requirements and provides data for-(a) calculating the working loads on buried vitrified clay pipes due to-(i) materials covering the pipes; and(ii) superimposed loads; and(b) selection of the crushing strength class for combinations of installation condition, support type, working load and factor of safety.AS 1741 specifies the minimum crushing load for each nominal size and crushing strength class of vitrified clay pipes.In addition, the Standard classifies installation conditions and support types and specifies requirements, including compaction, for the embedment.

First published as AS CA56-1968.
AS CA56 withdrawn-1991.
AS CA56 revised and redesignated AS 4060-1992.
Incorporating: Amdt 1-1993

£56.79
Excluding VAT