• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

AS 7240.10-2007

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire detection and alarm systems Point-type flame detectors

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

18-04-2007

Superseded date

02-03-2023

Superseded by

AS ISO 7240.10:2018

£84.54
Excluding VAT

1 - AS 7240.10-2007 Fire detection and alarm systems Part 10: Point-type flame detectors
4 - PREFACE
6 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
10 - 3 Terms and definitions
11 - 4 General requirements
11 - 4.1 Compliance
11 - 4.2 Classification
11 - 4.3 Individual alarm indication
11 - 4.4 Connection of ancillary devices
11 - 4.5 Monitoring of detachable detectors
11 - 4.6 Manufacturer's adjustments
12 - 4.7 On- site sensitivity adjustment
12 - 4.8 Marking
13 - 4.9 Data
13 - 4.10 Requirements for software- controlled detectors
13 - 4.10.1 General
13 - 4.10.2 Software documentation
14 - 4.10.3 Software design
14 - 4.10.4 Storage of programs and data
14 - 5 Tests
14 - 5.1 General
14 - 5.1.1 Atmospheric conditions for tests
15 - 5.1.2 Operating conditions for tests
15 - 5.1.3 Mounting arrangements
15 - 5.1.4 Tolerances
15 - 5.1.5 Determination of response point
16 - 5.1.6 Test procedure
16 - 5.1.7 Reduced functional tests
16 - 5.1.8 Provision for tests
17 - 5.1.9 Test schedule
18 - 5.1.10 Test report
18 - 5.2 Reproducibility
18 - 5.2.1 Object of test
18 - 5.2.2 Test procedure
19 - 5.2.3 Requirements
19 - 5.2.4 Object of test
19 - 5.3 Repeatability
19 - 5.3.1 Object of test
19 - 5.3.2 Test procedure
19 - 5.3.3 Requirements
19 - 5.4 Directional dependence
19 - 5.4.1 Object of test
19 - 5.4.2 Test procedure
20 - 5.4.3 Requirements
20 - 5.5 Fire sensitivity
20 - 5.5.1 Object of test
21 - 5.5.2 Test procedure
22 - 5.5.3 Classification
23 - 5.5.4 Requirements
23 - 5.6 Dazzling ( operational)
23 - 5.6.1 Object of test
24 - 5.6.2 Test procedure and apparatus
24 - 5.6.3 Requirements
24 - 5.7 Dry heat ( operational)
24 - 5.7.1 Object of test
25 - 5.7.2 Test procedure and apparatus
25 - 5.7.3 Requirements
25 - 5.8 Cold ( operational)
25 - 5.8.1 Object of test
25 - 5.8.2 Test procedure
26 - 5.8.3 Requirements
26 - 5.9 Damp heat, cyclic ( operational)
26 - 5.9.1 Object of test
26 - 5.9.2 Test procedure
27 - 5.9.3 Requirements
27 - 5.10 Damp heat, steady state ( endurance)
27 - 5.10.1 Object of test
27 - 5.10.2 Test procedure
28 - 5.10.3 Requirements
28 - 5.11 Sulfur dioxide ( SO2) corrosion ( endurance)
28 - 5.11.1 Object of test
28 - 5.11.2 Test procedure
28 - 5.11.3 Requirements
29 - 5.12 Shock ( operational)
29 - 5.12.1 Object of test
29 - 5.12.2 Test procedure and apparatus
29 - 5.12.3 Requirements
29 - 5.13 Impact ( operational)
29 - 5.13.1 Object of test
30 - 5.13.2 Test procedure
30 - 5.13.3 Requirements
30 - 5.14 Vibration, sinusoidal ( operational)
30 - 5.14.1 Object of test
30 - 5.14.2 Test procedure
31 - 5.14.3 Requirements
31 - 5.15 Vibration, sinusoidal ( endurance)
31 - 5.15.1 Object of test
32 - 5.15.2 Test procedure
32 - 5.15.3 Requirements
32 - 5.16 Variation of supply parameters ( operational)
32 - 5.16.1 Object of test
32 - 5.16.2 Test procedure
33 - 5.16.3 Requirements
33 - 5.17 Electromagnetic compatibility ( EMC) immunity tests ( operational)
33 - 5.17.1
33 - 5.17.2
33 - 6 Test report
34 - Annex A (normative) Marine test requirements
51 - Annex B (normative) Apparatus for response point determination
54 - Annex C (normative) Liquid (heptane) fire (TF5)
55 - Annex D (normative) Liquid (methylated spirit) fire (TF6)
56 - Annex E (normative) Apparatus for dazzling test
57 - Annex F (normative) Apparatus for impact test
59 - Annex G (informative) Example of methane burner

Specifies the requirements, methods of test and performance criteria for point-type, resettable flame detectors that operate using radiation from a flame for use in fire detection systems installed in buildings.

Committee
FP-002
DocumentType
Standard
ISBN
0 7337 8166 7
Pages
52
PublisherName
Standards Australia
RevisionOf
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
ISO 7240-10:2007 Identical

First published as AS 7240.10-2007.

AS 60068.2.78-2003 Environmental testing Tests - Test Cab: Damp heat, steady state (Reconfirmed 2018)
AS 60068.2.27-2003 Environmental testing Tests - Test Ea and guidance: Shock
AS 60068.1-2003 Environmental testing General and guidance (Reconfirmed 2018)
AS 60068.2.52-2003
AS 60068.2.6-2003 Environmental testing Tests - Test Fc: Vibration (sinusoidal) (Reconfirmed 2018)
AS/NZS 61000.4.4:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Electrical fast transient/burst immunity test
AS/NZS 61000.4.5:2006 Electromagnetic compatibility (EMC) Testing and measurement techniques - Surge immunity test
AS 60068.2.42-2004 Environmental testing Tests - Test Kc: Sulphur dioxide test for contacts and connections
AS 60068.2.10-2003 Environmental testing Tests - Test J and guidance: Mould growth
AS 60068.2.30-2003 Environmental testing Tests - Test Db and guidance: Damp heat, cyclic (12 + 12-hour cycle)
AS 60068.2.1-2003 Environmental testing Tests - Test A: Cold (Reconfirmed 2018)
AS/NZS 61000.4.2:2002 Electromagnetic compatibility (EMC) Testing and measurement techniques - Electrostatic discharge immunity test

AS 7240.20-2012 Fire detection and alarm systems Aspirating smoke detectors (Reconfirmed 2023)
AS 7240.1-2007 Fire detection and alarm systems - General and definitions
AS 4825-2011 Tunnel fire safety
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant

£84.54
Excluding VAT