AS/NZS 1429.1:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

16-06-2000

Superseded date

29-05-2024

Superseded by

AS/NZS 1429.1:2006

£67.62
Excluding VAT

1 - AS/NZS 1429.1:2000 ELECTRIC CABLES-POLYMERIC INSULATED - FOR WORKING VOLTAGES1.9/3.3 (3.6) kV up to and including19/...
4 - PREFACE
6 - CONTENTS
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 REFERENCED DOCUMENTS
9 - 1.3 DEFINITIONS
9 - 1.3.1 Approximate value
9 - 1.3.2 Collective screen
9 - 1.3.3 Conductor screen
9 - 1.3.4 Core (of a cable)
9 - 1.3.5 Direction of lay
9 - 1.3.6 Fictitious values
9 - 1.3.7 Gross cross-sectional area
9 - 1.3.8 Individual screen
9 - 1.3.9 Insulation screen
9 - 1.3.10 Length of lay
9 - 1.3.11 Maximum continuous conductor temperature
10 - 1.3.12 Nominal value
10 - 1.3.13 Non-hygroscopic
10 - 1.3.14 Qualification test report
10 - 1.3.15 Re-qualification tests
10 - 1.3.16 Routine tests
10 - 1.3.17 Sample tests
10 - 1.3.18 Type tests
10 - 1.4 VOLTAGE DESIGNATION
11 - 1.5 MAXIMUM CONDUCTOR TEMPERATURE
13 - SECTION 2 CONSTRUCTION
13 - 2.1 CONDUCTORS
13 - 2.2 CONDUCTOR SCREEN
13 - 2.2.1 Material and application
13 - 2.2.2 Thickness
13 - 2.2.3 Removal from conductor
13 - 2.2.4 Outer surface
13 - 2.2.5 Tests
13 - 2.2.6 Criteria
13 - 2.3 INSULATION
13 - 2.3.1 Material
13 - 2.3.2 Application
13 - 2.3.3 Thickness
13 - 2.3.4 Tests
14 - 2.3.5 Criteria
15 - 2.4 INSULATION SCREEN
15 - 2.4.1 Material and application
15 - 2.4.2 Thickness
15 - 2.4.3 Requirements for stripping insulation screens
16 - 2.4.4 Tests
16 - 2.4.5 Criteria
16 - 2.5 INDIVIDUAL OR COLLECTIVE SCREEN
16 - 2.5.1 General
16 - 2.5.2 Tests
16 - 2.5.3 Criteria
16 - 2.6 IDENTIFICATION OF CORES
17 - 2.7 LAYING-UP
17 - 2.8 FILLERS, BINDERS, AND BARRIER TAPES
17 - 2.9 METAL SHEATH
17 - 2.9.1 General
17 - 2.9.2 Material
17 - 2.9.3 Application
17 - 2.9.4 Thickness
17 - 2.9.5 Tests
18 - 2.9.6 Criteria
18 - 2.10 SEPARATION SHEATH
18 - 2.10.1 Material and application
18 - 2.10.2 Thickness
18 - 2.10.3 Tests
18 - 2.10.4 Criteria
18 - 2.11 BEDDING
18 - 2.11.1 Material
18 - 2.11.2 Application
19 - 2.11.3 Thickness
19 - 2.12 ARMOUR
19 - 2.12.1 General
19 - 2.12.2 Material
19 - 2.12.3 Application
19 - 2.12.4 Cables without metal sheath
19 - 2.12.5 Cables with metal sheath directly under armour
20 - 2.12.6 Diameter of armour wires
20 - 2.13 NON-METALLIC SHEATH
20 - 2.13.1 Material
20 - 2.13.2 Application
20 - 2.13.3 Colour
20 - 2.13.4 Thickness
21 - 2.13.5 Tests
21 - 2.13.6 Criteria
21 - 2.14 WATER-BLOCKING
21 - 2.14.1 General
21 - 2.14.2 Material and application
21 - 2.15 PROTECTION FROM INSECT ATTACK
22 - 2.16 CABLE IDENTIFICATION
22 - 2.17 METRE MARKING ON CABLE
22 - 2.18 PREPARATION FOR DELIVERY
22 - 2.19 MARKING OF DRUMS
23 - SECTION 3 TESTS
23 - 3.1 GENERAL
23 - 3.2 SELECTION OF SAMPLES
27 - 3.3 HIGH VOLTAGE TEST FOR 5 MIN
27 - 3.4 BENDING TEST FOLLOWED BY PARTIAL DISCHARGE TEST
27 - 3.4.1 Bending
28 - 3.4.2 Partial discharge test
28 - 3.5 MEASUREMENT OF DDF (TAN DELTA) AS A FUNCTION OF VOLTAGE
28 - 3.6 MEASUREMENT OF DDF (TAN DELTA) AT ELEVATED TEMPERATURE
28 - 3.7 HEAT CYCLING FOLLOWED BY PARTIAL DISCHARGE TEST
28 - 3.7.1 Heat cycling
28 - 3.7.2 Partial discharge test
28 - 3.8 IMPULSE WITHSTAND TEST FOLLOWED BY A HIGH VOLTAGE TEST
28 - 3.8.1 Preparation
28 - 3.8.2 Impulse withstand test
29 - 3.8.3 High voltage test for 15min
29 - 3.9 HIGH VOLTAGE A.C. TEST FOR 4H
29 - 3.10 RE-QUALIFICATION TESTS
29 - 3.10.1 Material changes
29 - 3.10.2 Process changes
31 - SECTION 4 REQUIREMENTS SPECIFIC TO CABLES COMPRISING INDIVIDUALLY SCREENED CORES
31 - 4.1 GENERAL
31 - 4.2 SPECIFIC REQUIREMENTS
31 - 4.2.1 Material
31 - 4.2.2 Application
31 - 4.2.3 Electrical requirements
32 - SECTION 5 REQUIREMENTS SPECIFIC TO THREE-CORE CABLES COMPRISING COLLECTIVELY SCREENED CORES
32 - 5.1 GENERAL
32 - 5.2 SPECIFIC REQUIREMENTS
32 - 5.2.1 Fillers and binder or barrier tapes
32 - 5.2.2 Collective screen
32 - 5.2.3 Tests
34 - APPENDIX A - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
34 - A1 INTRODUCTION
34 - A2 GENERAL
34 - A3 METHOD
34 - A3.1 Conductors
35 - A3.2 Cores
35 - A3.3 Diameter over lay-up of three-core cables
35 - A3.4 Bedding
35 - A3.5 Individual or collective screen
36 - A3.6 Separation sheath
36 - A3.7 Metal sheath
36 - A3.8 Armour
37 - APPENDIX B - PURCHASING GUIDELINES
37 - B1 GENERAL
37 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
37 - B3 ITEMS SUBJECT TO AGREEMENT BETWEEN PURCHASER AND MANUFACTURER
38 - APPENDIX C - RECOMMENDATIONS FOR CABLE INDIVIDUAL OR COLLECTIVE SCREENS
38 - C1 SCOPE
38 - C2 SCREEN CROSS-SECTIONAL AREA
39 - APPENDIX D - WATER PENETRATION TEST
39 - D1 SCOPE
39 - D2 PRINCIPLE
39 - D3 PREPARATION OF SAMPLE
39 - D4 APPARATUS
39 - D5 PROCEDURE
40 - D6 REPORT
41 - APPENDIX E - RECOMMENDED DIAMETER OF DRUM BARREL AND INSTALLATION BENDING RADIUS FOR CABLES
41 - E1 DIAMETER OF DRUM BARREL
41 - E2 INSTALLATION BENDING RADIUS
42 - APPENDIX F - TESTS AFTER INSTALLATION
42 - F1 SCOPE
42 - F2 HIGH VOLTAGE A.C. TEST AFTER INSTALLATION
42 - F3 ADVICE CONCERNING TESTS AFTER INSTALLATION
42 - F4 SHEATH INTEGRITY TEST
43 - APPENDIX G - SELECTION AND RETEST PROCEDURE FOR SAMPLE TESTS
43 - G1 SELECTION OF SAMPLES
43 - G2 RETEST PROCEDURE
44 - APPENDIX H - IMPULSE TEST
44 - H1 SCOPE
44 - H2 CHARACTERISTICS AND STATE OF THE TEST INSTALLATION AND TEST EQUIPMENT
44 - H2.1 Characteristics of the test installation to be subjected to the tests
44 - H2.2 Shape of the impulse waves
44 - H2.3 Calibration of impulse generator
45 - H3 PROCEDURE-APPLICATION OF THE PULSES
45 - H3.1 Positive pulses
45 - H3.2 Negative pulses
45 - H3.3 Oscillograms
45 - H3.4 Recording of temperatures
46 - APPENDIX I - ROUNDING OF NUMBERS
46 - I1 ROUNDING OF NUMBERS IN THE 'FICTITIOUS CALCULATION METHOD'
46 - I2 ROUNDING OF NUMBERS FOR OTHER PURPOSES

Specifies the requirements for cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated cables for fixed installations for electricity supply, with or without armour, including single-core and three-core cables comprising individually screened cores and three-core cables comprising collectively screened cores.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 3435 9
Pages
39
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard specifies requirements for cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) insulated cables for fixed installations for electricity supply.NOTE: Optional requirements for metal sheath, armour, water-blocking, protection from insect attack and metre marking on cable are provided in Clauses 2.9, 2.12, 2.14, 2.15 and 2.17 respectively.Sections 1 to 3 of this Standard cover the general requirements for cables with individually or collectively screened cores, Section 4 requirements are specific to cables with individually screened cores, and Section 5 requirements are specific to three-core cables with collectively screened cores.

First published as AS 1429.1-1979.
Revised and redesignated as AS 1429-1985.
Revised and redesignated as AS 1429.1-1993.
Jointly revised and designated as AS/NZS 1429.1:2000.

AS 3983-1991 Metal drums for insulated electric cables and bare conductors (Reconfirmed 2016)
AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
AS/NZS 1429.2:1998 Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV
AS/NZS 1660.2.5:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to cables above 1 kV
AS/NZS 2857:1996 Timber drums for insulated electric cables and bare conductors (Reconfirmed 2017)
AS 1125-1993 Conductors in insulated electric cables and flexible cords
AS/NZS 1660.5.2:1998 Test methods for electric cables, cords and conductors Fire tests - Smoke density
AS 1931.2-1996 High-voltage test techniques - Measuring systems
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS/NZS 1660.5.3:1998 Test methods for electric cables, cords and conductors Fire tests - Determination of the amount of halogen acid gas evolved during the combustion of polymeric materials taken from cables
AS/NZS 1660.2.4:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to polyethylene and polypropylene materials (Reconfirmed 2017)
AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials
AS/NZS 1660.5.4:1998 Test methods for electric cables, cords and conductors - Fire tests - Determination of degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring pH and conductivity
AS 2893-1986 Electric cables - Lead and lead alloy sheaths - Composition
AS/NZS 1660.5.5:1998 Test methods for electric cables, cords and conductors Fire tests - Circuit integrity under fire conditions
AS 1018-1985 Partial discharge measurements
AS/NZS 1660.5.1:1998 Test methods for electric cables, cords and conductors Fire tests - Tests on bunched cables
AS/NZS 1660.4:1998 Test methods for electric cables, cords and conductors Complete cable and flexible cord (Reconfirmed 2017)
AS/NZS 1660.5.6:1998 Test methods for electric cables, cords and conductors Fire tests - Test for combustion propagation
AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)
AS 3863-1991 Galvanized mild steel wire for armouring cables
AS/NZS 1660.2.3:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to PVC and halogen free thermoplastic materials (Reconfirmed 2017)
AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables

AS 1735.1-2001 Lifts, escalators and moving walks - General requirements
AS/NZS 4026:2001 Electric cables - For underground residential distribution systems
AS/NZS 1972:2006 Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020)
AS/NZS 4805.1:2001 Accessories for electric cables - Test requirements Power cables with extruded insulation for rated voltages from 1.9/3.3(3.6) kV up to and including 19/33(36) kV
AS/NZS 1972:2002 Electric cables - Underground coal mines - Other than reeling and trailing
AS 1735.1-2003 Lifts, escalators and moving walks General requirements
AS/NZS 3599.1:2003 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11 (12) kV and 12.7/22 (24) kV Metallic screened (Reconfirmed 2021)

£67.62