• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

AS/NZS 3012:2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Electrical installations - Construction and demolition sites

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

31-01-2003

Superseded date

30-07-2024

Superseded by

AS/NZS 3012:2010

£67.62
Excluding VAT
Summarise this standard

1 - AS/NZS 3012:2003 ELECTRICAL INSTALLATIONS-CONSTRUCTION AND DEMOLITION SITES
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE
7 - 1.2 APPLICATION
7 - 1.3 REFERENCED DOCUMENTS
7 - 1.4 DEFINITIONS
7 - 1.4.1 Appliance
7 - 1.4.2 Appliance, fixed
7 - 1.4.3 Appliance, hand-held
7 - 1.4.4 Appliance, portable
7 - 1.4.5 Appliance, stationary
7 - 1.4.6 Cable, flexible
7 - 1.4.7 Competent person
7 - 1.4.8 Construction and demolition site
7 - 1.4.9 Construction wiring
7 - 1.4.10 Cord, flexible
8 - 1.4.11 Electrical equipment
8 - 1.4.12 Fixed equipment
8 - 1.4.13 May
8 - 1.4.14 Permanent wiring
8 - 1.4.15 Portable socket-outlet assembly
8 - 1.4.16 Residual current device (RCD)
8 - 1.4.17 Shall
8 - 1.4.18 Should
9 - SECTION 2 INSTALLATION
9 - 2.1 SUPPLY
9 - 2.1.1 Construction wiring
9 - 2.1.2 Appliances, luminaires and electrical equipment
9 - 2.1.3 Identification of source of supply
9 - 2.1.4 Connection Devices
9 - 2.1.5 Polarization
9 - 2.1.6 Separate circuit requirements
9 - 2.2 MAXIMUM DEMAND
10 - 2.3 SWITCHBOARDS INSTALLED FOR THE PURPOSE OF CONSTRUCTION AND DEMOLITION
10 - 2.3.1 Location
10 - 2.3.2 Switchboard construction
10 - 2.3.3 Mounting of switchboards
11 - 2.3.4 Socket-outlets
11 - 2.3.5 Support of cables entering switchboards
11 - 2.4 CONTROL AND PROTECTION
11 - 2.4.1 Control
11 - 2.4.2 Securing of isolating switch
11 - 2.4.3 Marking of isolating switches
11 - 2.4.4 Size of marking
11 - 2.4.5 Overcurrent protection
12 - 2.4.6 Additional protection against direct and indirect contact
15 - 2.5 CONSTRUCTION WIRING
15 - 2.5.1 Cables and fittings
15 - 2.5.2 Installation of cables
15 - 2.5.3 Marking
15 - 2.5.4 Use of unarmoured cables
15 - 2.5.5 Location and marking of overhead wiring
16 - 2.5.6 Type of aerial conductor
16 - 2.5.7 Cables supported by a catenary
16 - 2.6 FLEXIBLE CORDS, CORD EXTENSION SETS, FLEXIBLE CABLES AND ACCESSORIES
16 - 2.6.1 General
16 - 2.6.2 Minimum conductor size and core configuration
16 - 2.6.3 Type of flexible cord and cable
16 - 2.6.4 Colour
16 - 2.6.5 Current-carrying capacity
17 - 2.6.6 Accessories for connection
17 - 2.6.7 Maximum length
17 - 2.6.8 Limitations on the use of cord extension sets
18 - 2.6.9 Protection of flexible cords or cables
18 - 2.6.10 Portable socket-outlet assemblies (PSOAs)
18 - 2.7 LIGHTING AND LUMINAIRES
18 - 2.7.1 Mechanical protection
18 - 2.7.2 Emergency evacuation lighting
19 - 2.7.3 Method of supply
19 - 2.7.4 Hand-held luminaires
19 - 2.7.5 Edison screw type lampholders
19 - 2.7.6 Festoon lighting
19 - 2.7.7 Portable luminaires
19 - 2.8 LIFT SHAFTS
19 - 2.8.1 General
20 - 2.8.2 Multiple lift shafts
20 - 2.8.3 Emergency lighting
20 - 2.8.4 False-car (Guided work platform)
20 - 2.9 RELOCATABLE CONSTRUCTION PREMISES
22 - SECTION 3 INSPECTION AND TESTING
22 - 3.1 APPLICATION
22 - 3.2 FREQUENCY OF INSPECTION AND TESTS
22 - 3.3 PERSONNEL
22 - 3.4 CONSTRUCTION WIRING
22 - 3.5 FIXED RCDS, PORTABLE RCDS AND RCDS TO BE USED WITH PORTABLE GENERATORS
23 - 3.6 RELOCATABLE CONSTRUCTION PREMISES AND OTHER ELECTRICAL EQUIPMENT ON SITE
23 - 3.7 CONNECTION BETWEEN GENERATOR WINDINGS OR FRAME AND EQUIPOTENTIAL BONDING SYSTEM
23 - 3.8 ACTIONS RESULTING FROM INSPECTION AND TEST
23 - 3.8.1 Construction wiring
23 - 3.8.2 Non-compliant equipment
23 - 3.8.3 Compliant equipment
24 - 3.9 DOCUMENTATION
25 - APPENDIX A - LIST OF REFERENCED DOCUMENTS
27 - APPENDIX B - ELECTRICAL INSTALLATIONS IN THE DOMESTIC HOUSING CONSTRUCTION INDUSTRY
27 - B1 GENERAL
27 - B2 SPECIFIC CLAUSE VARIATIONS
28 - APPENDIX C - CLASSIFICATION OF BUILDINGS AND STRUCTURES
28 - C1 PRINCIPLES OF CLASSIFICATION
28 - C2 CLASSIFICATIONS
30 - APPENDIX D - REGULATORY APPLICATION ON CONSTRUCTION AND DEMOLITION SITES
30 - D1 GENERAL
30 - D2 REGULATORY AUTHORITIES AND REGULATORY INSTRUMENTS
30 - D2.1 New South Wales
31 - D2.2 Victoria
31 - D2.3 Queensland
31 - D2.4 Australian Capital Territory
32 - D2.5 Tasmania
32 - D2.6 Northern Territory
33 - D2.7 South Australia
33 - D2.8 Western Australia
34 - D2.9 New Zealand
35 - APPENDIX E - MARKING OF SWITCHBOARDS TO INDICATE THE PRESENCE OF LIVE PARTS
36 - APPENDIX F - RECOMMENDED COLOURS FOR TAGS ON TESTED EQUIPMENT

Sets out requirements for electrical installations which supply electricity to equipment on construction and demolition sites. Includes requirements for the inspection and testing of electrical equipment used on building construction sites.

Committee
EL-001
DocumentType
Standard
ISBN
0 7337 5032 X
Pages
31
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

This Standard sets out minimum requirements for the design, construction and testing of electrical installations which supply electricity to appliances and equipment on construction and demolition sites, and for the in-service testing of portable, relocatable and fixed electrical equipment used on construction and demolition sites. For a single domestic residence intended to be occupied as a residential housing unit, or, adjoining units each with a separate exterior entry and intended to be occupied as residential housing units, the requirements of this Standard are varied as detailed in Appendix B. NOTE: Guidance to applicable types of construction is given in Appendix C. The requirements are intended to protect persons, livestock and property from electric shock, fire and physical injury hazards that may arise from an electrical installation that is used with reasonable care and with due regard to the intended purpose of the electrical installation. NOTE: For requirements and recommendations regarding safe working on or near electrical equipment and installations, refer to AS/NZS 4836, Safe working on low-voltage electrical installations. This Standard applies to electrical installations associated with construction and demolition sites which include— (a) building work, excavation work, compressed air work and diving work; (b) parts of buildings which undergo structural alterations, such as extensions, major repairs or demolition, to the extent that the work necessitates the provision of a temporary electrical installation; (c) work on or in connection with the construction or maintenance of roads, airfields or airstrips, civil engineering works or bridges, or of the permanent way of a railway or tramway; (d) dredging or salvaging work; (e) the laying, lining or maintenance of pipes or cables; (f) earthmoving work carried out with equipment requiring the use of other than manual power; (g) any work in which explosives are used; (h) site offices, cloakrooms, meeting rooms, dormitories, canteens, toilets, appliances and other facilities provided during any work referred to in (a) to (g); and (i) land clearing in preparation for any work referred to in (a) to (g).

First published in Australia as AS 3012-1990.
Jointly revised and designated as Joint Standard AS/NZS 3012:1995.
Third edition 2003.

⚠

A newer version of this standard is available.

View Current Edition
£67.62
Excluding VAT