• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 3200.2.30:2001

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Medical electrical equipment Particular requirements for safety - Automatic cycling non-invasive blood pressure monitoring equipment (IEC 60601-2-30:1999, MOD)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

12-11-2001

Superseded date

29-07-2024

Superseded by

AS 80601.2.30:2018

£83.47
Excluding VAT

1 - AS/NZS 3200.2.30:2001 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-AUTOMATIC CYCLING NON-INVASIVE BLOOD
4 - PREFACE
6 - CONTENTS
8 - INTRODUCTION
9 - SECTION ONE – GENERAL
9 - 1 Scope and object
9 - *1. 1 Scope
9 - 1.2 Object
9 - 1.3 Particular Standards
10 - 2 Terminology and definitions
11 - 3 General requirements
12 - 4 General requirements for tests
12 - 5 Classification
12 - 6 Identification, marking and documents
13 - SECTION TWO – ENVIRONMENTAL CONDITIONS
13 - SECTION THREE – PROTECTION AGAINST ELECTRIC SHOCK HAZARDS
13 - 14 Requirements related to classification
14 - 17 Separation
14 - 19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
14 - 20 Dielectric strength
14 - SECTION FOUR – PROTECTION AGAINST MECHANICAL HAZARDS
14 - 21 Mechanical strength
15 - 22 Moving parts
16 - SECTION FIVE – PROTECTION AGAINST HAZARDS FROM UNWANTED OR EXCESSIVE RADIATION
16 - 36 ELECTROMAGNETIC COMPATIBILITY
19 - SECTION SIX – PROTECTION AGAINST THE HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
19 - SECTION SEVEN – PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS
19 - 42 Excessive temperatures
20 - 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection, and compatibility
20 - 45 Pressure vessels and parts subject to PRESSURE
20 - 49 Interruption of the power supply
21 - SECTION EIGHT – ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
21 - 50 Accuracy of operating data
21 - 51 Protection against hazardous output
27 - SECTION NINE – ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
27 - SECTION TEN – CONSTRUCTIONAL REQUIREMENTS
27 - 56 Components and general assembly
28 - 57 MAINS PARTS, components and lay-out
36 - Annex L - References – Publications mentioned in this standard
37 - Annex AA - General guidance and rationale
44 - Annex BB - Alarm diagrams
48 - APPENDIX ZZ - VARIATIONS TO IEC 60601-2-30:1999 FOR APPLICATION IN AUSTRALIA AND NEW ZEALAND
48 - ZZ1 INTRODUCTION
48 - ZZ2 VARIATION

Specifies the particular requirements for the safety, including essential performances, of automatic cycling non-invasive blood pressure monitoring equipment, which may be attended or unattended. It does not apply to blood pressure measuring equipment which uses finger transducers or to semi-automatic blood pressure measuring equipment, typically in which each determination needs to be initiated manually. This Standard is to be read in conjunction with AS/NZS 3200.1.0:1998. It modifies and has been reproduced from IEC 60601-2-30:1999 with variations for Australia and New Zealand included in Appendix ZZ.

Committee
HE-003
DocumentType
Standard
ISBN
0 7337 4038 3
Pages
40
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
IEC 60601-2-30:1999 Identical

First published as AS/NZS 3200.2.30:1996.
Second edition 2001.

AS ISO 1000-1998 The international system of units (SI) and its application
AS/NZS 2064:1997 Limits and methods of measurement of electromagnetic disturbance characteristics of industrial, scientific and medical (ISM) radiofrequency equipment
AS/NZS 3200.1.2:2005 Medical electrical equipment General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests
AS/NZS 3200.1.0-1998 Medical electrical equipment General requirements for safety - Parent Standard
AS/NZS 3200.2.2:1999 Medical electrical equipment - Particular requirements for safety - High frequency surgical equipment
AS/NZS 3200.1.4:1997 Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Programmable electrical medical systems

AS/NZS 60335.2.90:2006 Household and Similar Electrical Appliances - Safety Particular requirements for commercial microwave ovens
AS/NZS 4173:2018 Safe use of lasers and intense light sources in health care
AS/NZS 60745.1:2009 Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD)
AS 4774.2-2002 Work in compressed air and hyperbaric facilities - Hyperbaric oxygen facilities

£83.47
Excluding VAT