AS/NZS 3599.2:1999

Current

Current

The latest, up-to-date edition.

Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened (Reconfirmed 2017)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-06-1999

£56.79
Excluding VAT

Specifies the construction, dimensions and test requirements for three phase, aerial bundled cables incorporating a support conductor, insulated with cross-linked polyethylene and non-metallic screened (without further protection).

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 2753 0
Pages
22
ProductNote
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
PublisherName
Standards Australia
Status
Current
Supersedes

This Standard specifies the construction, dimensions and test requirements for cross-linkedpolyethylene (XLPE) insulated, non-metallic screened (without further protection), three phase, aerialbundled cables (ABC) incorporating a support conductor (see Figures 1 and 2), for electricity supply.NOTE: Cable data to assist in the selection of the appropriate cables is given in Appendix C.

Originated in Australia as AS 3599.2-1991.
Jointly revised and designated AS/NZS 3599.2:1999.

AS/NZS 2857:1996 Timber drums for insulated electric cables and bare conductors (Reconfirmed 2017)
AS 3983-1991 Metal drums for insulated electric cables and bare conductors
AS 1125-1993 Conductors in insulated electric cables and flexible cords
AS 1429.1-1993 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS/NZS 1429.1:2006 Electric cables - Polymeric insulated For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV (Reconfirmed 2017)
AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
AS/NZS 1429.2:1998 Electric cables - Polymeric insulated - For working voltages above 19/33 (36) kV up to and including 76/132 (145) kV
AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 1931.2-1996 High-voltage test techniques - Measuring systems
AS 1531-1991 Conductors - Bare overhead - Aluminium and aluminium alloy
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)

AS/NZS 7000:2016 Overhead line design
HB 331-2012 Overhead line design
AS/NZS 7000:2010 Overhead line design - Detailed procedures
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables

£56.79