• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 4695.2.41:1996

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Fire hazard testing of electrotechnical products Test methods - 1 kW nominal premixed test flame and guidance

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

05-05-1996

Superseded date

30-06-2017

Superseded by

AS/NZS 60695.11.2:2004

£29.61
Excluding VAT

1 - AS/NZS 4695.2.41:1996 FIRE HAZARD TESTING OF ELECTROTECHNICAL PRODUCTS - TEST METHODS - 1 kW NOMINAL PREMIXED TEST FLAME AND
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - 1 Scope
7 - 2 Normative references
7 - 3 Definition
8 - 4 Requirements
8 - 5 Production and confirmation of the test flame
8 - 5.1 Production
8 - 5.2 Confirmation
8 - 5.2.1 Principle
8 - 5.2.2 Procedure
9 - 5.2.3 Calculate the mean time in seconds as the result .
9 - 5.2.4 The flame is confirmed and may be used for test purposes if the result is within the range 45 s ± 5 s.
9 - 5.3 Apparatus
9 - 5.3.1 Burner
9 - 5.3.2 Flowmeters
9 - 5.3.3 Manometers
9 - 5.3.4 Control valves
9 - 5.3.5 Copper block
9 - 5.3.6 Thermocouple
10 - 5.3.7 Temperature time indicating/recording and timing devices
10 - 5.3.8 Means of measuring the ambient air temperature and pressure are also required.
10 - 5.3.9 Fuel gas-propane with a purity > 98 %.
10 - 5.3.10 Air-essentially free of oil and water.
10 - 6 Recommended arrangements for use of the test flame
10 - 7 Classification and designation
19 - Annex A - Exampl e of test arrangements
20 - Amendment 1
21 - ANNEX ZA - VARIATIONS BETWEEN THIS STANDARD AND IEC 695-2-4/1:1991

Gives detailed requirements for the production of a 1 kW nominal, propane-based premixed test flame, its approximate overall height being 175 mm. This Standard is technically equivalent to and reproduced from IEC 695-2-4/1:1991.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 0371 2
Pages
13
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This section of IEC 695-2 gives the detailed requirements for the production of the 1 kW nominal, propane based pre-mixed type test flame. The approximate overall flame height is 175 mm.This section should be used in conjunction with IEC 695-2-4/0 and the other guidance publications in IEC 695.

Standards Relationship
IEC 60695-2-4/1:1991 Identical

First published as AS/NZS 4695.2.41:1996.

AS/NZS 4695.2.40:1996 Fire hazard testing of electrotechnical products Test methods - Diffusion type and premixed flame test methods

AS/NZS 4695.2.40:1996 Fire hazard testing of electrotechnical products Test methods - Diffusion type and premixed flame test methods
AS/NZS 2053.5:2001 Conduits and fittings for electrical installations Corrugated conduits and fittings of insulating material (Reconfirmed 2016)
AS/NZS 2053.1:2001 Conduits and fittings for electrical installations General requirements (Reconfirmed 2016)
AS/NZS 2053.6:2001 Conduits and fittings for electrical installations Profile-wall, smooth-bore conduits and fittings of insulating material (Reconfirmed 2016)

£29.61