• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS 5000.1:2005

Current

Current

The latest, up-to-date edition.

Electric cables - Polymeric insulated For working voltages up to and including 0.6/1 (1.2) kV (Reconfirmed 2017)

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

17-11-2005

£56.79
Excluding VAT

Specifies the construction, dimensions and test requirements for single- and multicore cables insulated with polymeric materials intended for use at working voltages up to and including 0.6/1 (1.2) kV. It does not apply to polymeric insulated cables for special installations and service conditions or for which there are separate Australian/New Zealand Standards.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 7004 5
Pages
25
ProductNote
Reconfirmed 20/01/2017.This standard has been reconfirmed in Australia in 2017 and remains current in New Zealand. Reconfirmation Notice 20/01/2017
PublisherName
Standards Australia
Status
Current
Supersedes
UnderRevision

This Standard specifies construction, dimensions and tests for single- and multicore cables insulated with polymeric materials intended for use in electrical installations at working voltages up to and including 0.6/1 (1.2)kV.It does not apply to polymeric insulated cables for special installations and service conditions or for which there are separate Australian/New Zealand Standards, e.g. neutral screened cables, welding cables, flexible cords and aerial bundled cables.NOTES: 1 Purchasing guidelines are contained in AppendixA.2 AS/NZS3008.1 should be referenced to assist correct cable size selection for the intended application and installation.

Originated as AS/NZS 5000.1:1999.
Second edition 2003, incorporating AS 3178-1991.
Third edition 2005.
Reissued incorporating Amendment No. 1 (December 2006).

AS/NZS 4507:1998 Cables - Fire performance
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3560.2:2003 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1 (1.2) kV Copper conductors (Reconfirmed 2017)
AS/NZS 1660.1:1998 Test methods for electric cables, cords and conductors Conductors and metallic components (Reconfirmed 2017)
AS/NZS 3008.1.2:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand installation conditions
AS/NZS 1660.2.3:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to PVC and halogen free thermoplastic materials (Reconfirmed 2017)
AS/NZS 1125:2001 Conductors in insulated electric cables and flexible cords (Reconfirmed 2017)
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables
AS/NZS 4961:2003 Electric cables - Polymeric insulated - For distribution and service applications (Reconfirmed 2017)
AS/NZS 1660.5.6:2005 Test methods for electric cables, cords and conductors Fire tests - Test for vertical flame propagation for a single insulated wire or cable
AS/NZS 1660.3:1998 Test methods for electric cables, cords and conductors Electrical tests (Reconfirmed 2017)
AS 2706-2003 Numerical values - Rounding and interpretation of limiting values (Reconfirmed 2018)
AS/NZS 1660.2.2:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods specific to elastomeric, XLPE and XLPVC materials
AS 3008.1-1989 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV
AS/NZS 3008.1.1:1998 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 2893:2002 Electric cables - Lead and lead alloy sheaths - Composition (Reconfirmed 2017)
AS/NZS 3863:2002 Galvanized mild steel wire for armouring of cables (Reconfirmed 2017)
AS/NZS 1660.2.1:1998 Test methods for electric cables, cords and conductors Insulation, extruded semi-conductive screens and non-metallic sheaths - Methods for general application (Reconfirmed 2017)
AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)

AS/ACIF S008-2006 Requirements for customer cabling products
AS/NZS 3001:2001 Electrical installations - Relocatable premises (including caravans and tents) and their site installations
AS/NZS 3012:2010 Electrical installations - Construction and demolition sites
AS/NZS 2243.6:2010 Safety in laboratories Plant and equipment aspects
AS/NZS 3015:2004 Electrical installations - Extra-low voltage d.c. power supplies and service earthing within public telecommunications networks
AS/NZS 3003:2018 Electrical installations - Patient areas
AS/NZS 1768:2007 Lightning protection
AS 2832.1-2004 Cathodic protection of metals Pipes and cables
AS/NZS 5000.2:2006 Electric cables - Polymeric insulated For working voltages up to and including 450/750 V
AS 1530.4-2005 Methods for fire tests on building materials, components and structures Fire-resistance test of elements of construction
AS/NZS 4026:2001 Electric cables - For underground residential distribution systems
AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS/NZS 1972:2006 Electric cables - Underground coal mines - Other than reeling and trailing (Reconfirmed 2020)
AS/NZS 3008.1.1:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS/NZS 3003:2003
AS/NZS 3003:2011 Electrical installations - Patient areas
AS 2353:2018 Pedestrian push-button assemblies
AS 2144:2014 Traffic signal lanterns
AS/NZS 1802:2003 Electric cables - Reeling and trailing - For underground coal mining purposes
AS/NZS 4026:2008 Electric cables - For underground residential distribution systems (Reconfirmed 2018)
AS/NZS 3008.1.2:2010 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS/NZS 3123:2005 Approval and test specification - Plugs, socket-outlets and couplers for general industrial application (Reconfirmed 2016)
AS/NZS 3004.1:2008 Electrical installations - Marinas and recreational boats Marinas
AS/NZS 1802:2018 Electric cables - Reeling and trailing - For underground coal mining
AS/NZS 4703:2007 Electrical wiring in furniture (Reconfirmed 2018)
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance General requirements
AS/NZS 3013:2005 Electrical installations - Classification of the fire and mechanical performance of wiring system elements (Reconfirmed 2020)
AS/NZS 5139:2019 Electrical installations - Safety of battery systems for use with power conversion equipment
AS/NZS 3001:2008 Electrical installations - Transportable structures and vehicles including their site supplies
AS/NZS 3004:2002 Electrical installations - Marinas and pleasure craft at low-voltage
AS/NZS 2201.1:2007 Intruder alarm systems Client’s premises - Design, installation, commissioning and maintenance
AS 2832.2-2003 Cathodic protection of metals Compact buried structures (Reconfirmed 2016)
AS/NZS 3008.1.1:2009 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical Australian installation conditions
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures (Reconfirmed 2016)
AS 2832.5-2008 Cathodic protection of metals Steel in concrete structures
AS/NZS 3008.1.2:2017 Electrical installations - Selection of cables Cables for alternating voltages up to and including 0.6/1 kV - Typical New Zealand conditions
AS/NZS 3439.1:2002 Low-voltage switchgear and controlgear assemblies Type-tested and partially type tested assemblies (IEC 60439-1:1999 MOD)
AS/NZS 1299:2009 Electrical equipment for mines and quarries - Explosion-protected three-phase restrained plugs and receptacles for working voltages up to and including 3.3 kV (Reconfirmed 2020)
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2832.4-2006 Cathodic protection of metals Internal surfaces (Reconfirmed 2016)
AS/NZS 2144:2002 Traffic signal lanterns

£56.79
Excluding VAT