AS/NZS 60155:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Glow-starters for fluorescent lamps

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Published date

11-08-2000

Superseded date

29-05-2024

Superseded by

AS 60155:2018

£56.02
Excluding VAT

1 - AS/NZS 60155:2000 GLOW-STARTERS FOR FLUORESCENT LAMPS
4 - PREFACE
5 - CONTENTS
6 - INTRODUCTION
7 - 1 Scope
7 - 2 Normative references
8 - 3 Definitions
8 - 3.1 starter:
8 - 3.2 glow-starter:
8 - 3.3 non-reclosure voltage:
8 - 3.4 deactivated lamp:
8 - 3.5 glow-starters with operating time limitation:
8 - 4 General requirements
8 - 5 General requirements for tests
8 - 6 Marking
9 - 7 Requirements and tests for safety
9 - 7.1 Type test quantity
9 - 7.2 Conditions of acceptance
9 - 7.3 Protection against accidental electric shocks
9 - 7.4 Insulation resistance under humidity conditions
10 - 7.5 Dielectric strength
10 - 7.6 Dimensions
10 - 7.7 Torsion test
10 - 7.8 Mechanical strength
10 - 7.9 Connections
10 - 7.10 Resistance to heat and fire
11 - 7.11 Quality of marking
11 - 7.12 Radio interference suppression capacitors
12 - 7.13 Heating of starters with operating time limitation
12 - 7.101 Ignitability and combustion propagation
13 - 8 Starting test
13 - 8.1 Starting test quantity
13 - 8.2 Conditions of acceptance
13 - 8.3 Conditions of test
13 - 8.4 Speed of operation
14 - 8.5 Closed time
14 - 8.6 Non-reclosure voltage
14 - 8.7 Pulse voltage
14 - 9 Endurance test
14 - 9.1 Test quantity
14 - 9.2 Conditions of acceptance
14 - 9.3 Conditions of test
15 - 10 Deactivated lamp test
15 - 10.1 Test quantity
15 - 10.2 Conditions of acceptance of starters without operating time limitation
15 - 10.3 Conditions of test
15 - 10.4 Conditions of acceptance for starters with operating time limitation
16 - 10.5 Operating time limitation test
16 - 11 Information for luminaire design
27 - Annex A - Ballasts to be used for life testing
28 - Annex B - Starters for class II fluorescent lamp luminaires
31 - Annex C - Information for luminaire design

Specifies general and safety requirements for glow-starters for fluorescent lamps. It is reproduced from IEC 60155:1993 and IEC 60155/Amd.1:1995 but has additional local requirements for ignitability and combustion propagation. In Australia it supersedes both AS 3138-1993 and AS 4111-1993 on 1 January 2002.

Committee
EL-041
DocumentType
Standard
ISBN
0 7337 3068 X
Pages
25
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

This standard specifies interchangeable glow-starters used with pre-heat type fluorescent lamps, hereafter called "starters".Section 1 specifies the general and safety requirements with which starters shall comply.Section 2 specifies the performance.NOTE - Starters are generally designed to operate with a range of lamps, depending on supply voltage, single lamp or series pair operation, maximum lamp voltage and lamp starting requirements.Glow-starters for use in class II luminaires shall comply with annex B.

Standards Relationship
IEC 60155:1993 Identical

First published as AS 3138-1993 and AS 4111-1993.
Jointly revised and redesignated as AS/NZS 60155:2000.

AS/NZS 60598.1:2001 Luminaires General requirements and tests (IEC 60598.1:1996, MOD)
AS/NZS 60598.2.22:2005 Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2 22, Ed. 3.1(2002) MOD)
AS/NZS 60921:2002 Ballasts for tubular fluorescent lamps - Performance requirements
AS/NZS 60901:2003 Single-capped fluorescent lamps - Performance specifications
AS/NZS 61000.3.2:2003 Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current less than or equal to 16 A per phase)
AS/NZS CISPR 15:2002 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15:2000, MOD)
AS/NZS 61000.3.2:2013 Electromagnetic compatibility (EMC) Limits - Limits for harmonic current emissions (equipment input current less than or equal to16 A per phase)
AS/NZS 60598.1:2013
AS/NZS 60927:2005 Auxiliaries for lamps - Starting devices (other than glow starters) - Performance requirements (IEC 60927, Ed.2.2 (2004) MOD)
AS/NZS 60079.15:2011 Explosive atmospheres Equipment protection by type of protection 'n'
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 4782.1:2004 Double-capped fluorescent lamps - Performance specifications General (IEC 60081:2000, MOD) (Reconfirmed 2016)
AS/NZS 60598.2.1:2014 Luminaires Particular requirements - Fixed general purpose luminaires

£56.02