• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Meet Inform Select. Always-on access to the Standards your organisation relies on. Explore Inform Select

AS/NZS IEC 61935.1:2006

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Testing of balanced communication cabling in accordance with ISO/IEC 11801 Installed cabling

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English

Published date

11-10-2006

Superseded date

13-03-2023

Superseded by

AS/NZS IEC 61935.1:2012

£113.82
Excluding VAT

1 - AS/NZS IEC 61935.1:2006 TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH ISO/IEC 11801 - INSTALLED CABLING
4 - PREFACE
5 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope
9 - 2 Normative references
10 - 3 Terms and definitions
13 - 4 Reference measurement procedures for electrical properties
13 - 4.1 General
13 - 4.2 Test equipment considerations
13 - 4.2.1 Network analyser test requirements
13 - 4.2.2 Termination of conductor pairs
14 - 4.2.3 Reference loads for calibration
14 - 4.2.4 Test configurations
16 - 4.2.5 Coaxial cables and test leads for network analysers
16 - 4.2.6 Balun requirements
18 - 4.2.7 Network analyser measurement precautions
18 - 4.2.8 Data reporting and accuracy
19 - 4.3 DC loop resistance
19 - 4.3.1 Object
19 - 4.3.2 Test method
19 - 4.3.3 Test equipment and set- up
19 - 4.3.4 Procedure
20 - 4.3.5 Test report
20 - 4.3.6 Uncertainty
20 - 4.4 Direct current ( d. c.) resistance unbalance
20 - 4.4.1 Object
21 - 4.4.2 Test equipment and set- up
21 - 4.4.3 Procedure
21 - 4.4.4 Test report
21 - 4.4.5 Uncertainty
22 - 4.5 Insertion loss
22 - 4.5.1 Object
22 - 4.5.2 Test method
22 - 4.5.3 Test equipment and set- up
23 - 4.5.4 Procedure
23 - 4.5.5 Test report
23 - 4.5.6 Temperature correction
23 - 4.5.7 Uncertainty
23 - 4.6 Propagation delay and delay skew
23 - 4.6.1 Object
24 - 4.6.2 Test method
24 - 4.6.3 Test equipment and set-up
24 - 4.6.4 Procedure
25 - 4.6.5 Test report
25 - 4.6.6 Uncertainty of propagation delay and delay skew measurements
25 - 4.7 Near- end crosstalk ( NEXT), pair to pair and power sum
25 - 4.7.1 Object
25 - 4.7.2 Test method
25 - 4.7.3 Test equipment and set- up
26 - 4.7.4 Procedure
27 - 4.7.5 Test report
27 - 4.7.6 Uncertainty of NEXT measurements
27 - 4.8 Attenuation to crosstalk ratio ( ACR), pair to pair and power sum
27 - 4.8.1 Object
28 - 4.8.2 Test method
28 - 4.8.3 Test equipment and set- up
28 - 4.8.4 Procedure
28 - 4.8.4.1 Calculation
28 - 4.8.5 Test report
28 - 4.8.6 Uncertainty of ACR measurements
28 - 4.9 Far- end crosstalk ( FEXT), pair to pair and power sum
29 - 4.9.1 Object
29 - 4.9.2 Test method
29 - 4.9.3 Test equipment and set- up
30 - 4.9.4 Procedure
30 - 4.9.5 Test report
30 - 4.9.6 Uncertainty of FEXT measurements
31 - 4.10 Equal level far- end crosstalk ( ELFEXT)
31 - 4.10.1 Object
31 - 4.10.2 Calculation
31 - 4.10.3 Test report
31 - 4.10.4 Uncertainty of ELFEXT measurements
31 - 4.11 Return loss
32 - 4.11.1 Object
32 - 4.11.2 Test method
32 - 4.11.3 Test equipment and set- up
32 - 4.11.4 Procedure
33 - 4.11.5 Test report
33 - 4.11.6 Uncertainty of return loss measurements
33 - 4.12 Unbalance attenuation
33 - 4.13 Coupling attenuation
33 - 5 Field test measurement requirements for electrical properties
33 - 5.1 General
34 - 5.2 Cabling configurations tested
34 - 5.3 Field test parameters
34 - 5.3.1 General
34 - 5.3.2 Inspection of workmanship and connectivity testing
36 - 5.3.3 Propagation delay and delay skew
36 - 5.3.4 Length
37 - 5.3.5 Insertion loss
37 - 5.3.6 Pair to pair Next, power sum Next
38 - 5.3.7 ACR ( pair- to- pair and power sum)
39 - 5.3.8 Pair- to- pair ELFEXT, power sum ELFEXT
39 - 5.3.9 Return loss
39 - 5.3.10 Direct current ( d. c.) loop resistance
40 - 5.4 Data reporting and accuracy
40 - 5.4.1 General
41 - 5.4.2 Detailed results
41 - 5.4.3 Summary results
46 - 5.5 Field measurement procedures
46 - 5.5.1 General
46 - 5.5.2 Consistency checks for field testers
46 - 5.5.3 Evaluation of consistency tests
46 - 5.5.4 Administration system applicability
46 - 5.5.5 Test equipment adapter cords for link testing
47 - 5.5.6 User cords and channel testing
47 - 6 Field tester measurement accuracy requirements
47 - 6.1 General
49 - 6.2 Measurement accuracy specifications common to level IIE, level III and level IV field testers
49 - 6.3 Accuracy performance requirements for level IIE field testers
51 - 6.4 Accuracy performance requirements for level III field testers
53 - 6.5 Accuracy performance requirements for level IV field testers
55 - 6.6 Procedures for determining field tester parameters
55 - 6.6.1 General
55 - 6.6.2 Output signal balance ( OSB)
56 - 6.6.3 Common mode rejection ( CMR)
57 - 6.6.4 Residual NEXT
58 - 6.6.5 Dynamic acuracy
59 - 6.6.6 Source/ load return loss
59 - 6.6.7 Random noise floor
59 - 6.6.8 Residual FEXT
60 - 6.6.9 Directivity
61 - 6.6.10 Tracking
61 - 6.6.11 Source match
61 - 6.6.12 Return loss of remote termination
62 - 6.6.13 Constant error term of the propagation delay measurement function
62 - 6.6.14 Error constant proportional to propagation delay of the propagation delay measurement function
62 - 6.6.15 Constant error term of the delay skew measurement function
62 - 6.6.16 Constant error term of the length measurement function
62 - 6.6.17 Error constant proportional to length of the length measurement function
63 - 6.6.18 Constant error term of the d. c. resistance measurement function
63 - 6.6.19 Error constant proportional to d. c. resistance of the d. c. resistance measurement function
63 - 6.7 Measurement error models
63 - 6.7.1 General
69 - 6.8 Network analyser measurement comparisons
69 - 6.8.1 General
69 - 6.8.2 Adapters
72 - 6.8.3 Comparison methods
76 - Bibliography

Adopts IEC 61935-1:2005 to specify reference measurement procedures for cabling parameters and the requirements for field tester accuracy to measure cabling parameters identified in ISO/IEC 11801.

Committee
CT-001
DocumentType
Standard
ISBN
0 7337 7776 7
Pages
68
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 61935-1:2005 Identical

Originated as AS/NZS 3087.1:2000.
Previous edition AS/NZS 3087.1:2003.
Jointly revised and redesignated as AS/NZS IEC 61935.1:2006.

AS/NZS 3080:2003 Telecommunications installations - Generic cabling for commercial premises (ISO/IEC 11801:2002, MOD)

AS/NZS ISO/IEC 24702:2007 Telecommunications installations - Generic cabling - Industrial premises
HB 29-2007 Communications cabling manual - Module 2: Communications cabling handbook
AS/NZS IEC 61935.2:2006 Testing of balanced communication cabling in accordance with ISO/IEC 11801 Patch cords and work area cords
AS/NZS ISO/IEC 24764:2012 Generic cabling systems for data centres
HB 252-2007 Communications Cabling Manual - Module 3: Residential communications cabling handbook