BS 4833:1986

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Schedule for hygrometric tables for use in the testing and operation of environmental enclosures

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

30-09-1986

Superseded date

31-07-2009

£306.00
Excluding VAT

Foreword
Committees responsible
Schedule
1. Scope
2. Basis of tables
3. Applicability of tables
4. Tables
Appendices
A. Variation of relative humidity with dry-bulb
    temperature and wet-bulb depression (atmospheric
    pressure 1013 hPa)
B. Bibliographical references
Tables
1a. Relative humidity from dry-bulb readings from 1 deg
    C to 50 deg C and wet bulb depressions up to 15
    degrees Celsius at 1013 hPa pressure
1b. Dew-point temperature from dry-bulb readings from
    1 deg C to 50 deg C and wet-bulb depressions up to
    15 degrees Celsius at 1013 hPa pressure
2a. Relative humidity from dry-bulb readings from 51 deg
    C to 99 deg C and wet-bulb depressions up to 15
    degrees Celsius at 1013 hPa pressure
2b. Dew-point temperature from dry-bulb readings from
    51 deg C to 99 deg C and wet-bulb depressions up to
    15 degrees Celsius at 1013 hPa pressure
3a. Relative humidity from dry-bulb readings from 2 deg
    C to 98 deg C and wet-bulb depressions above 15
    degrees Celsius at 1013 hPa pressure
3b. Dew-point temperature from dry-bulb readings from
    2 deg C to 98 deg C and wet-bulb depressions above
    15 degrees Celsius at 1013 hPa pressure
4. increase in relative humidity compared with 1972
    edition, from dry-bulb readings from 2 deg C to
    98 deg C and wet-bulb depressions up to 40 degrees
    Celsius at 1013 hPa pressure
5. Correction for atmospheric pressure to relative
    humidity values in tables 1a, 2a and 3a at a pressure
    of 1013 hPa, from dry-bulb readings from 2 deg C to
    98 deg C and pressures in hPa, for a wet-bulb
    depression of 10 degrees Celsius

Contains tables and equations for the determination of relative humidity and dew point from the readings of a forced-ventilated wet- and dry-bulb hygrometer or aspirated psychrometer over the range of dry-bulb temperatures from 1°C to 99°C at 1013 hPa.

Committee
W/-
DevelopmentNote
Supersedes BS 4833(1972) & 85/50496 DC. (07/2005)
DocumentType
Standard
Pages
62
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

BS 1339:1965 Definitions, formulae and constants relating to the humidity of the air
BS 3718:1964 Specification for laboratory humidity ovens (non-injection type)
BS 4864:1973 Recommendations on the design and testing of enclosures for environmental testing
BS 3898:1965 Specification for laboratory humidity ovens (injection type)
BS 4194:1967 Recommendations on the design requirements and testing of controlled-atmosphere laboratories

£306.00
Excluding VAT