Code of practice for oil firing Installations up to 44 kW output capacity for space heating and hot water supply purposes

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-03-1977

Superseded date

15-01-1998

Superseded by

BS 5410-1:1997

£232.00
Excluding VAT
Summarise this standard

Foreword
Cooperating organizations
Specification
Section one. General
1. Scope
2. References
Section two. Liquid fuels
3. Types of petroleum oil fuels
4. Typical petroleum oil fuel characteristics
Section three. Appliances and burners
5. Types of appliance
6. Types of burner
7. Selection of appliance
Section four. Oil storage tanks and equipment
8. Types
9. Capacity
10. Design and test conditions
11. Oil level indicators and gauges
12. Overfilling alarm and signalling system
13. Pressure unloading device
14. Filling pipes and connections
15. Vent pipes
16. Installation of tanks
17. Tank supports
18. Painting and cleaning
Section five. Oil system from storage tank to burner
19. Fuel supply systems
20. Fuel feed pipework
Section six. Accommodation for boilers and air heaters
21. General
22. Location of appliances
23. Provision for air combustion and ventilation
24. Appliance temperature and its relation to
     surrounding building materials
Section seven. Accommodation for oil storage tanks for
single family dwellings
25. General
26. Siting of oil storage tanks
27. Methods of tank protection
28. Requirements for tank accommodation
29. Catchpits
Section eight. Flues and chimneys
30. Choice of materials
31. Design and construction of chimneys
32. Size and height of chimneys
33. Height and position of chimneys above roofs
34. Shared chimneys
35. Structural chimneys
36. Factory made insulated chimneys
37. Insulated flue pipes used as chimneys
38. Single skin flue pipes used as chimneys
39. Liners for chimneys
40. Chimney terminals
41. External cladding
42. Flue pipes for connecting appliances to chimneys
43. Dampers
44. Inspection and cleaning
45. Appliances designed to operate with integral flue
     systems
46. Inspection and testing on site
Section nine. Electrical and control requirements
47. Electrical requirements
48. Purpose of controls
Section ten. Commissioning
49. General
50. Responsibilities of the commissioning engineer
Section eleven. Maintenance
51. General
52. Access for maintenance
53. Manuals
54. Safety controls
Section twelve. Conversions of existing appliances
55. General
56. Technical recommendations
Section thirteen. Legal requirements
57. General
58. Summary of regulations
Appendix
A. Gravity oil pipe sizing
Tables
1. Specification data for class C2 and class D
     petroleum oil fuels as given in BS 2869: 1970
2. Typical characteristics of class C2 and class D
     petroleum oil fuels
3. Minimum hot water storage capacity for typical
     households in temperate climates
4. External tank site distance requirements
5. Materials for flue pipes connecting appliances
     to chimneys
Figures
1. Typical perforated sleeve burner
2. Typical natural draught pot burner
3. Typical mechanical draught pot burner
4. Typical mechanical draught pot burner with a
     central air diffuser
5. Typical rotary vaporizing burner
6. Typical pressure jet burner
7. Typical oil supply system: gravity feed
8. Typical oil supply system: sub-gravity feed with
     oil filter
9. Typical oil supply system: sub gravity feed flow
10. Nomogram for gravity oil pipe sizing: class C2
     fuel (keros ne)
11. Nomogram for gravity oil pipe sizing: class D fuel
     (gas oil)

Applies, where relevant, to oil fired cookers where these are connected to flues. Does not apply to oil firing in marine and transportable installations, or in flueless heaters.

Committee
RHE/13
DevelopmentNote
Supersedes BS CP3002-2(1964) (07/2004)
DocumentType
Standard
Pages
32
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
£232.00
Excluding VAT