• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS 5410-1:2014

Superseded

Superseded

View Superseded by

Code of practice for oil firing Installations up to 45 kW output capacity for space heating and hot water supply purposes

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-12-2014

Superseded date

23-08-2019

Superseded by

BS 5410-1:2019

£322.00
Excluding VAT
Summarise this standard

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Liquid fuels
5 Installation of oil fired appliances
6 Oil storage tanks and equipment
7 Accomodation for oil storage tanks
8 Installation of tanks
9 Oil system from storage tank to burner
10 Flues and chimneys
11 Design and installation of flues and chimneys
12 Room sealed balanced flue appliances
13 Special categories of flue system
14 Electrical installation and system controls
15 Commissioning
16 Maintenance
17 Conversion of appliances to oil firing
18 Biofuels
Annexes
Annex A (informative) - Types of appliances and burners
        covered by this standard
Annex B (informative) - Example of a chimney designation
        in accordance with BS EN 1443:2003
Bibliography

Provides recommendations and guidance on the design, installation, commissioning and maintenance of oil burning installations up to 45 kW output capacity for space heating and hot water supply purposes.

Committee
RHE/13
DevelopmentNote
Supersedes BS 5410-1(1997) & 14/30285453 DC. (01/2015)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

This part of BS5410 gives recommendations and guidance on the design, installation, commissioning and maintenance of oil burning installations up to 45kW output capacity for space heating and hot water supply purposes. It also gives recommendations and guidance on the selection and installation of oil tanks of capacity up to 3500L, when installed at buildings used primarily as dwellings. The standard is also applicable to oil fired cookers where these are connected to flues. This part of BS5410 is not applicable to oil fired systems for marine and transportable installations, or for flueless heaters. This part of BS5410 is applicable to installations burning liquid fuel conforming to BS2869:2010+A1 , including biofuels conforming to BSEN14214 , and blends thereof. This standard is intended for use by designers, specifiers, installers, and service and commissioning engineers. NOTE1 The types of appliances and burners covered by this part of BS5410 are described in AnnexA. NOTE2 Oil tank installations at buildings used primarily as dwelllings, with an oil storage capacity greater than 3500L are covered by BS5410‑2:2013 . NOTE3 Oil tank installations at buildings other than dwellings, with oil storage capacity up to 3500L, are covered by BS5410‑2:2013 , 10.7 .

⚠

A newer version of this standard is available.

View Current Edition
£322.00
Excluding VAT