• Shopping Cart
    There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert
Celebrate World Standards Day. Save 10% with code WSD2026 until 31 Oct. Save now

BS 5628-2:2000

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Code of practice for use of masonry Structural use of reinforced and prestressed masonry

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

15-11-2000

Superseded date

28-12-2005

Superseded by

BS 5628-2:2005

£322.00
Excluding VAT
Summarise this standard

Committees responsible
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols
5 Alternative materials and methods of design and
      construction
6 Materials and components
7 Design objectives and general recommendations
8 Design of reinforced masonry
9 Design of prestressed masonry
10 Other design considerations
11 Work on site
Annex A (normative) Design method for walls incorporating
                    bed joint reinforcement to enhance
                    lateral load resistance
Annex B (informative) Wall tie for high-lift cavity walls
Annex C (informative) Estimation of deflection
Annex D (normative) Method for determination of
                    characteristic strength of brick
                    masonry, fk
Annex E (informative) Durability recommendations for various
                      construction types
Bibliography
Index
Figure 1 - Characteristic compressive strength, fk, of
           masonry
Figure 2 - Short-term design stress-strain curve for
           reinforcement
Figure 3 - Moment of resistance factor, Q
Figure 4 - Hooks and bends
Figure 5 - Typical short-term design stress-strain curves
           for normal and low relaxation tendons
Figure 6 - Minimum concrete cover in pocket-type walls and
           in reinforced hollow blockwork walls
Figure B.1 - Wall tie for high-lift grouted-cavity wall
Figure D.1 - Typical prisms for determination of fk
Table 1 - Requirements for mortar
Table 2 - Chloride content of mixes
Table 3 - Characteristic compressive strength, fk, of masonry
Table 4 - Characteristic tensile strength of reinforcing
          steel, fy
Table 5 - Characteristic anchorage bond strength
Table 6 - Elastic modulus for concrete infill, Ec
Table 7 - Partial safety factors, gmm, for strength of
          reinforced masonry in direct compression and
          bending: ultimate limit state
Table 8 - Partial safety factors, gmv, hm and gms: ultimate
          limit state
Table 9 - Limiting ratios of span to effective depth for
          laterally-loaded walls
Table 10 - Limiting ratios of span to effective depth for
           beams
Table 11 - Values of the moment of resistance factor, Q, for
           various values of fk/gmm and lever arm factor, C
Table 12 - Effective height of walls and columns
Table 13 - Values of the coefficient j
Table 14 - Selection of reinforcement for durability
Table 15 - Minimum concrete cover for carbon steel
           reinforcement
Table 15a - Adjustments to minimum cement contents for
            aggregates other than 20 mm nominal maximum size
Table D.1 - Value of k
Table D.2 - Value of reduction factor to allow for ratio h/t
Table E.1 - Durability recommendations for various
            construction types

Gives recommendations for the structural design of reinforced and prestressed masonry constructed of brick or block masonry or masonry of square dressed natural stone.

Committee
B/525/6
DevelopmentNote
Supersedes BS 5628-2(1995) and 98/104044 DC. (09/2002)
DocumentType
Standard
Pages
66
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

⚠

A newer version of this standard is available.

View Current Edition
£322.00
Excluding VAT