BS EN 1090-3:2008
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
Execution of steel structures and aluminium structures Technical requirements for aluminium structures
Hardcopy , PDF
English
31-08-2008
22-04-2019
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Specifications and documentation
4.1 Execution specification
4.1.1 General
4.1.2 Execution classes
4.1.3 Tolerance types
4.1.4 Tolerance class for shell structures
4.1.5 Testing and acceptance criteria for welding
4.2 Constructor's documentation
4.2.1 Quality documentation
4.2.2 Quality plan
4.2.3 Safety during erection
4.2.4 Execution documentation
5 Constituent products
5.1 General
5.2 Identification, inspection documents and traceability
5.3 Parent material
5.4 Aluminium products
5.5 Welding consumables
5.6 Mechanical fasteners
5.6.1 Bolts, nuts and plain washers
5.6.2 Studs
5.6.3 Rivets
5.6.4 Self-drilling and self-tapping screws
5.6.5 Bearings
5.7 Adhesive bonding
6 Preparation
6.1 General
6.2 Identification
6.3 Handling, storage and transportation
6.4 Cutting
6.5 Forming
6.6 Holing for fasteners
6.7 Cut outs
6.8 Full contact bearing surfaces
6.9 Assemblies
6.10 Heat treatment
6.11 Straightening
7 Welding
7.1 General
7.2 Welding plan
7.2.1 Requirement for a welding plan
7.2.2 Content of a welding plan
7.3 Welding process
7.4 Qualification of welding procedures and welding personnel
7.4.1 Qualification of welding procedures
7.4.2 Validity of the welding procedure qualification
7.4.3 Qualification of welders and welding operators
7.4.4 Welding coordination personnel
7.5 Preparation and execution of welding
7.5.1 General
7.5.2 Joint preparation
7.5.3 Weather protection
7.5.4 Assembly for welding
7.5.5 Temporary attachments
7.5.6 Tack welds
7.5.7 Preheating and interpass temperature
7.5.8 Butt welds
7.5.9 Slot and plug welds
7.5.10 Other welds
7.6 Acceptance criteria
7.7 Post-weld heat treatment
8 Mechanical fastening and adhesive bonding
8.1 Joint assembly for mechanical fastening
8.1.1 Preparation of contact surfaces
8.1.2 Fit-up
8.1.3 Preparations of contact surfaces in slip-resistant
connections
8.2 Bolted connections
8.2.1 General
8.2.2 Bolts
8.2.3 Fitted bolts
8.2.4 Countersunk bolts
8.2.5 Nuts
8.2.6 Washers
8.3 Tightening of bolted connections
8.3.1 Non-preloaded connections
8.3.2 Preloaded connections
8.4 Riveting
8.4.1 General
8.4.2 Installation of rivets
8.5 Fastening of cold formed members and sheeting
8.6 Adhesive bonded connections
9 Erection
9.1 General
9.2 Site conditions
9.3 Erection method statement
9.4 Supports
9.5 Execution on site
9.5.1 Site survey
9.5.2 Marking
9.5.3 Handling and storage at site
9.5.4 Erection methods
9.5.5 Alignment and grouting
9.6 Protection of surfaces, cleaning after erection
10 Surface treatment
10.1 General
10.2 Protection of the structure and components
10.3 Protection of contact surfaces and fasteners
10.3.1 General
10.3.2 Contact surfaces aluminium-to-aluminium and
aluminium-to-plastics
10.3.3 Contact surfaces of aluminium and steel or wood
10.3.4 Contact surfaces of aluminium and concrete,
brickwork and plaster, etc.
10.3.5 Fasteners
10.3.6 Bonded joints
10.4 Fire protection
11 Geometrical tolerances
11.1 Types of tolerances
11.2 Essential tolerances
11.2.1 General
11.2.2 Manufacturing tolerances
11.2.3 Erection tolerances
11.3 Functional tolerances
11.3.1 General
11.3.2 Manufacturing tolerances
12 Inspection, testing and corrections
12.1 General
12.2 Constituent products and components
12.2.1 Constituent products
12.2.2 Components
12.3 Preparation
12.3.1 Forming
12.3.2 Geometrical dimensions of components
12.4 Welding
12.4.1 Inspection stages
12.4.2 Methods of inspection and personnel qualification
12.4.3 Extent of inspection
12.4.4 Acceptance criteria for welds
12.4.5 Repair welds
12.4.6 Inspection of temporary attachment locations
after removal
12.5 Mechanical fasteners
12.5.1 Inspection of connections with non-preloaded bolts
12.5.2 Inspection of connections with preloaded bolts
12.5.3 Inspection of riveted connections
12.6 Adhesive bonding
12.7 Nonconforming products
12.7.1 Nonconforming constituent products
12.7.2 Nonconforming components and structures
Annex A (normative) - Required additional information, options to
be specified and requirements for execution classes
A.1 List of required information
A.2 List of options to be specified
A.3 Requirements related to execution classes
Annex B (informative) - Checklist for the content of a quality plan
B.1 Introduction
B.2 Content
B.2.1 Management
B.2.2 Specification review
B.2.3 Documentation
B.2.4 Inspection and testing procedures
Annex C (normative) - Cruciform weld test
C.1 Introduction
C.2 Test piece
C.3 Examination and testing
Annex D (normative) - Procedure for determination of slip factor
D.1 The purpose of testing
D.2 Significant variables
D.3 Test specimens
D.4 Slip test procedure and evaluation of results
D.5 Extended creep test procedure and evaluation
D.6 Test results
Annex E (informative) - Fastening of cold formed members and sheeting
E.1 General
E.2 Use of self-tapping and self-drilling screws
E.3 Use of blind rivets
E.4 Fastening sidelaps
Annex F (informative) - Surface treatment
F.1 Anodic oxidation
F.2 Coatings
F.2.1 General
F.2.2 Pre-treatment
F.2.3 Base coat
F.2.4 Final coat
F.2.5 Coatings with bitumen or bituminous combinations
F.2.6 Repair coatings
F.3 Passivation
Annex G (normative) - Geometrical tolerances - Essential tolerances
G.1 Manufacturing tolerances
G.1.1 General
G.1.2 Welded I-sections
G.1.3 Welded box sections
G.1.4 Webs
G.1.5 Components
G.1.6 Base plates and end plate connections
G.1.7 Column splices
G.1.8 Lattice components
G.2 Erection tolerances
G.2.1 Columns
G.2.2 Beams
G.2.3 Full contact bearing
Annex H (normative) - Geometrical tolerances - Functional tolerances
H.1 General
H.2 Manufacturing tolerances
H.2.1 Box sections
H.2.2 Components
H.2.3 Stiffeners
H.2.4 Fastener holes, notches and edges
H.2.5 Lattice components
H.3 Erection tolerances
H.3.1 Columns
H.3.2 Beams, rafters and trusses
H.4 Bridges
Annex I (normative) - Geometrical tolerances - Shell structures
I.1 General
I.2 Out-of roundness tolerances
I.3 Non-intended eccentricity due to execution
I.4 Dent tolerances
I.5 Interface flatness tolerances
Annex J (informative) - Designation of requirements to welds on
drawings
J.1 General
J.2 Global specification
J.3 Specific designations for welds, part of welds, details
Annex K (informative) - Recommendations for description of site
conditions and erection in the execution specification
K.1 Site conditions
K.2 Erection method statement
Annex L (informative) - Guide for preparation of the execution
specification for quality requirements of welds
L.1 General
L.2 Utilization grades and utilization ranges
L.2.1 General
L.2.2 Utilization grade for components and structures
in service category SC1
L.2.3 Utilization grade for components and structures
in service category SC2
L.3 Extent of additional NDT
L.3.1 Extent of NDT (%) for components/structures in
service category SC1
L.3.2 Extent of additional NDT (%) for
components/structures in service category SC2
L.4 Acceptance criteria for welds
L.4.1 Acceptance criteria for welds in service
category SC1
L.4.2 Acceptance criteria for welds in service
category SC2
Annex M (informative) - Guide for specification of quality
requirements for components and structures in SC2
Annex N (informative) - Chart for development and use of a
welding procedure specification (WPS)
Bibliography
Describes requirements independent of the type and shape of the aluminium structure, and this is applicable to structures under predominantly static loads as well as structures subject to fatigue. It specifies requirements related to the execution classes that are linked with consequence classes.
| Committee |
B/525/9
|
| DevelopmentNote |
Supersedes DD ENV 1090-3 & 05/30133060 DC. (08/2008)
|
| DocumentType |
Standard
|
| Pages |
116
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| SupersededBy | |
| Supersedes | |
| UnderRevision |
This European Standard specifies requirements for the execution of aluminium structural components and structures made from: a) rolled sheet, strip and plate; b) extrusions; c) cold drawn rod, bar and tube; d) forgings; e) castings. NOTE 1 The execution of structural components is referred to as manufacturing, in accordance with EN 1090-1. This European Standard specifies requirements independent of the type and shape of the aluminium structure, and this European Standard is applicable to structures under predominantly static loads as well as structures subject to fatigue. It specifies requirements related to the execution classes that are linked with consequence classes. NOTE 2 Consequence classes are defined in EN 1990. NOTE 3 Recommendations for selection of execution class in relation to consequence class are given in EN 1999-1-1. This European Standard covers components made of constituent products with thickness not less than 0,6 mm for welded components not less than 1,5 mm. This European Standard applies to structures designed according to the relevant parts of EN 1999. If this European Standard is used for structures designed according to other design rules or used for other alloys and tempers not covered by EN 1999, a judgement of the reliability elements in these design rules should be made. This European Standard specifies requirements for surface preparation prior to application of a protective treatment, and gives guidelines for application for such treatment in an informative annex. This European Standard gives options for specifying requirements to match project specific requirements. This European Standard is also applicable to temporary aluminium structures.
| Standards | Relationship |
| EN 1090-3:2008 | Identical |
| EN 1090-3:2019 | Identical |
| I.S. EN 1090-3:2008 | Equivalent |
| DIN EN 1090-3:2008-09 | Equivalent |
A newer version of this standard is available.