Walk-in cold rooms. Definition, thermal insulation performance and test methods Customized cold rooms

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

13-12-2018

£322.00
Excluding VAT

This document provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions.

Committee
RHE/19
DocumentType
Standard
ISBN
9780580969683
Pages
52
ProductNote
This standard also refers :- EN 13166, EN 13162, ETAG 21, NF P 75-401-1 (DTU 45.1), EN 13165, EN 13164 , EN ISO 10456 ,en 13163 , EN 13167 This standard is identical to EN 16855-2
PublisherName
British Standards Institution
Status
Current

This document provides test or calculation methods to assess thermal insulation performances for customized walk-in cold rooms and components under normal end-use conditions. The normal end-use conditions of a walk-in cold room are considered to be: - installation inside an existing building; - not exposed to external weather conditions; - internal side of panels subject to temperatures within the indicative range ?40 °C ? T ? 12 °C; - external side of panels subject to temperatures within the indicative range ?8 °C ? T ? 30 °C; temperatures below 0 °C, or higher than 20 °C, can be reached if the walk-in cold room is located inside not air-conditioned premises. NOTE In case the customized walk-in cold room working at positive storage temperature is used as a food processing room or a clean room, the standard is applied.

Standards Relationship
EN 16855-2:2018 Identical
I.S. EN 16855-2:2018 Equivalent
EN 16855‑2 : 2018 Identical