BS EN 55016-2-1:2014
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specification for radio disturbance and immunity measuring apparatus and methods Methods of measurement of disturbances and immunity. Conducted disturbance measurements
Hardcopy , PDF
English
31-07-2014
03-08-2020
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Types of disturbance to be measured
5 Connection of measuring equipment
6 General measurement requirements and conditions
7 Measurement of disturbances conducted along leads,
9 kHz to 30 MHz
8 Automated measurement of disturbances
9 Test set-up and measurement procedure using the
CDNE in the frequency range 30 MHz to 300 MHz
Annex A (informative) - Guidelines to connection of
electrical equipment to the artificial mains
network
Annex B (informative) - Use of spectrum analyzers and
scanning receivers
Annex C (informative) - Decision tree for use of detectors
for conducted measurements
Annex D (informative) - Scan rates and measurement times
for use with the average detector
Annex E (informative) - Guidelines for the improvement of
the test setup with ANs
Annex F (normative) - Determination of suitability of spectrum
analyzers for compliance tests
Annex G (informative) - Basic Guidance for measurements on
telecommunications ports
Annex H (normative) - Specifics for conducted disturbance
on telecommunication ports
Annex I (informative) - Examples of AANs and ANs for screened
cables
Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Describes the methods of measurement of disturbance phenomena in general in the frequency range 9 kHz to 18 GHz and especially of conducted disturbance phenomena in the frequency range 9 kHz to 30 MHz.
| Committee |
GEL/210/11
|
| DevelopmentNote |
Together with BS EN 55016-2-2, BS EN 55016-2-3 and BS EN 55016-2-4 it supersedes BS CISPR 16-2(1996). (02/2005) Supersedes 05/30138085 DC. (07/2009) Supersedes 08/30189220 DC. (07/2011) 2009 + A1 2011 Edition remains current and will be withdrawn on 22/04/2016. Supersedes 10/30233455 DC. (07/2013) 2009 + A2 2013 Edition remains active & will be withdrawn on 02/04/2017. Supersedes 11/30246802 DC. (07/2014)
|
| DocumentType |
Standard
|
| Pages |
112
|
| PublisherName |
British Standards Institution
|
| Status |
Withdrawn
|
| Supersedes |
CISPR 16-2-1:2014 is designated a basic standard, which specifies the methods of measurement of disturbance phenomena in general in the frequency range 9 kHz to 18 GHz and especially of conducted disturbance phenomena in the frequency range 9 kHz to 30 MHz. With a CDNE, the frequency range is 9 kHz to 300 Hz. This third edition cancels and replaces the second edition published in 2008, Amendment 1:2010 and Amendment 2:2013. This edition constitutes a technical revision which includes added methods of measurement using a new type of ancillary equipment: the CDNE. Key Words: electromagnetic compatibility, EMC, emissions, immunity
| Standards | Relationship |
| DIN EN 55016-2-1 : DEC 2014 | Identical |
| I.S. EN 55016-2-1:2014 | Identical |
| CISPR 16-2-1:2014 | Identical |
| EN 55016-2-1:2014 | Identical |
| UNE-EN 55016-2-1:2015 | Identical |
| EN 55016-2-1:2014 | Equivalent |
| NF EN 55016-2-1 : 2014 AMD 1 2017 | Identical |
| NEN EN 55016-2-1 : 2014 AMD 1 2017 | Identical |
This standard has been withdrawn and is no longer current. No replacement edition is available.