BS EN 60099-8:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Surge arresters Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a.c. systems above 1 kV
Hardcopy , PDF
English
30-06-2011
30-04-2018
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Identification and classification
5 Standard ratings and service conditions
6 Requirements
7 General testing procedure
8 Type tests
9 Routine tests
10 Acceptance tests
Annex A (informative) - Example of a test circuit
for the follow current interrupting test
Annex B (normative) - Mechanical considerations
Bibliography
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Describes surge arresters to protect the insulator assembly from lightning-caused overvoltages only.
| Committee |
PEL/37
|
| DevelopmentNote |
Supersedes 09/30167595 DC. (07/2011)
|
| DocumentType |
Standard
|
| Pages |
66
|
| PublisherName |
British Standards Institution
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
This part of IEC 60099 covers metal-oxide surge arresters with external series gap (externally gapped line arresters (EGLA) that are applied on overhead transmission and distribution lines, only to protect insulator assemblies from lightning-caused flashovers.
This standard defines surge arresters to protect the insulator assembly from lightning-caused overvoltages only. Therefore, and since the metal-oxide resistors are not permanently connected to the line, the following items are not considered for this standard:
switching impulse sparkover voltage;
residual voltage at steep current and switching current impulse;
thermal stability;
long-duration current impulse withstand duty;
power-frequency voltage versus time characteristics of an arrester;
disconnector test;
aging duties by power-frequency voltage.
Considering the particular design concept and the special application on overhead transmission and distribution lines, some unique requirements and tests are introduced, such as the verification test for coordination between insulator withstand and EGLA protective level, the follow current interrupting test, mechanical load tests, etc.
Designs with the EGLA\'s external series gap installed in parallel to an insulator are not covered by this standard.
| Standards | Relationship |
| IEC 60099-8:2017 | Identical |
| I.S. EN 60099-8:2011 | Equivalent |
| EN 60384-14-2:2004 | Identical |
| EN 60099-8:2011 | Identical |
| IEC 60099-8:2011 | Identical |
| IEC 60384-14-2:2004 | Identical |
| UNE-EN 60099-8:2011 | Equivalent |
| EN 60099-8:2011 | Equivalent |