INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting of motor-operated appliances
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at
operating temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers
and associated circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
Annex A (informative) - Routine tests
Annex B (normative) - Appliances powered by
rechargeable batteries
Annex C (normative) - Ageing test on motors
Annex D (normative) - Thermal motor protectors
Annex E (normative) - Needle-flame test
Annex F (normative) - Capacitors
Annex G (normative) - Safety isolating transformers
Annex H (normative) - Switches
Annex I (normative) - Motors having basic insulation
that is inadequate for the rated voltage of the appliance
Annex J (normative) - Coated printed circuit boards
Annex K (normative) - Overvoltage categories
Annex L (informative) - Guidance for the measurement
of clearances and creepage distances
Annex M (normative) - Pollution degree
Annex N (normative) - Proof tracking test
Annex O (informative) - Selection and sequence of the tests
of Clause 30
Annex P (informative) - Guidance for the application of this
standard to appliances used in warm damp equable climates
Annex Q (informative) - Sequence of tests for the evaluation
of electronic circuits
Annex R (normative) - Software evaluation
Index of defined words
Annex ZA (normative) - Special national conditions
Annex ZB (informative) - A-deviations
Annex ZC (normative) - Normative references to international
publications with their corresponding European publications
Annex ZD (informative) - IEC and CENELEC code designations
for flexible cords
Annex ZE (informative) - Specific additional requirements
for appliances and machines intended for commercial use
Annex ZF (informative) - Criteria applied for the allocation
of products covered by standards in the EN 60335 series
under LVD or MD
Annex ZG (normative) - UV appliances
Annex ZZA (informative) - Relationship between this European
Standard and the safety
objectives of Directive 2014/35/EU [2014 OJ L96] aimed
to be covered
Annex ZZB (informative) - Relationship between this European
Standard and the essential requirements of Directive
2006/42/EC aimed to be covered
National annex NA (informative) - Original IEC text prior to
amendment by CENELEC common modifications
Bibliography
Describes the safety of electrical appliances for household environment and commercial purposes, their rated voltage being not more than 250 V for single-phase and 480 V for others.
Committee |
CPL/61
|
DevelopmentNote |
Supersedes 98/264754 DC 00/242019 DC, 02/206590 DC, 03/306056 DC, BS 3456-201(1990), BS 3456-1(1969) & BS 3456-101(1987). Supersedes 05/30132579 DC. Supersedes 09/30206804 DC & 10/30238095 DC. (11/2011) Supersedes 08/30192264 DC. (05/2012) (09/2014) 2012 Edition Re-Issued in December 2017 & incorporates AMD 13 2017. 2012 + A11 2014 edition remains current and will be withdrawn on 03/05/2020. (01/2018)
|
DocumentType |
Standard
|
Pages |
200
|
PublisherName |
British Standards Institution
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
|
Standards | Relationship |
UNE-EN 60335-1:2012 | Identical |
NEN EN 60335-1 : 95 AMD 14 1998 | Identical |
NF EN 60335-1 : 2013 | Identical |
I.S. EN 60335-1:2012 | Identical |
DIN EN 60335-1 : 2012 COR 2 2014 | Identical |
SN EN 60335-1 : 2012 AMD 12 2017 | Identical |
NBN EN 60335-1 : 2012 AMD 1 2014 | Identical |
EN 60335-1:2012 | Identical |
09/30181298 DC : 0 | BS 7657 - SPECIFICATION FOR FUSES (CUT-OUTS), ANCILLARY TERMINAL BLOCKS AND INTERCONNECTING UNITS UP TO 100 A RATING, FOR POWER SUPPLIES TO BUILDINGS |
BS PAS 60-2(2004) : 2004 | EQUIPMENT USED IN THE CONTROLLED REMOVAL OF ASBESTOS-CONTAINING MATERIALS - PART 2: NEGATIVE PRESSURE UNITS - SPECIFICATION |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 7977-1(2009) : 2009 | SPECIFICATION FOR SAFETY AND RATIONAL USE OF ENERGY OF DOMESTIC GAS APPLIANCES - PART 1: RADIANT/CONVECTORS |
BS 7430(2011) : 2011 | CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
15/30320088 DC : 0 | BS 8611 - ROBOTS AND ROBOTIC DEVICES - GUIDE TO THE ETHICAL DESIGN AND APPLICATION OF ROBOTS AND ROBOTIC SYSTEMS |
BS 5900:1999 | Specification for powered domestic lifts with partially enclosed cars and no lift-well enclosures |
BS 7654:2010 | Specification for single-phase street lighting cut-out assemblies for low-voltage public electricity distribution systems. 25 A rating for highway power supplies and street furniture |
BS 8494:2007 | Electronic portable and transportable apparatus designed to detect and measure carbon dioxide in indoor ambient air. Requirements and test methods |
13/30283398 DC : 0 | BS 7656+A1 - SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 315 ARATING |
BS 7860:1996 | Specification for carbon monoxide detectors (electrical) for domestic use |
BS EN 50193:1997 | Closed electrical instantaneous water heaters. Methods for measuring performance |
BS 8611:2016 | Robots and robotic devices. Guide to the ethical design and application of robots and robotic systems |
09/30181290 DC : 0 | BS 7654 - SPECIFICATION FOR SINGLE-PHASE STREET LIGHTING FUSES (CUT-OUTS) FOR LOW-VOLTAGE PUBLIC ELECTRICITY DISTRIBUTION SYSTEMS - 25 A RATING FOR HIGHWAY POWER SUPPLIES AND STREET FURNITURE |
BS 7657:2010 | Specification for cut-out assemblies up to 100 A rating, for power supply to buildings |
BS EN 50165:1997 | Electrical equipment of non-electric appliances for household and similar purposes. Safety requirements |
BS 7977-1:2002 | Specification for safety and rational use of energy of domestic gas appliances Radiant/convectors |
11/30249994 DC : DRAFT JULY 2011 | BS 7430 - CODE OF PRACTICE FOR PROTECTIVE EARTHING OF ELECTRICAL INSTALLATIONS |
95/717426 DC : DRAFT JAN 1996 | SPECIFICATION FOR DOMESTIC GAS FIRED HEATING APPLIANCES - PART 2: COMBINED APPLIANCES - GAS FIRE/BACK BOILER |
08/30166387 DC : DRAFT MAY 2008 | BS 7977-1 - SPECIFICATION FOR SAFETY AND RATIONAL USE OF ENERGY OF DOMESTIC GAS APPLIANCES - PART 1: RADIANT/CONVECTORS |
07/30154996 DC : 0 | BS 8494 - ELECTRONIC PORTABLE APPARATUS DESIGNED TO DETECT AND MEASURE CARBON DIOXIDE IN INDOOR AMBIENT AIR |
BS 7656(1993) : 1993 | SPECIFICATION FOR LOW-VOLTAGE POLE-MOUNTING FUSES (CUT-OUTS) - 400 A RATING |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60950-1:2005+AMD1:2009+AMD2:2013 CSV | Information technology equipment - Safety - Part 1: General requirements |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60320-1:2015 | Appliance couplers for household and similar general purposes - Part 1: General requirements |
EN 50525-2-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-21: CABLES FOR GENERAL APPLICATIONS - FLEXIBLE CABLES WITH CROSSLINKED ELASTOMERIC INSULATION |
IEC GUIDE 110:2014 | Home control systems - Guidelines relating to safety |
EN 50525-2-83:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-83: Cables for general applications - Multicore cables with crosslinked silicone rubber insulation |
EN 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
EN 50525-2-82:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-82: Cables for general applications - Cables with crosslinked elastomeric insulation for decorative chains |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
EN 50525-3-41:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-41: Cables with special fire performance - Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke |
EN 60238 : 2004 AMD 2 2011 | EDISON SCREW LAMPHOLDERS (IEC 60238:2004/A2:2011) |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60730-2-10:2006 | Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays |
EN 60085:2008 | Electrical insulation - Thermal evaluation and designation |
EN 61000-4-11:2004/A1:2017 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017) |
CEN/CLC Guide 6:2014 | Guide for addressing accessibility in standards |
EN 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
EN 60309-4:2007/A1:2012 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 4: SWITCHED SOCKET-OUTLETS AND CONNECTORS WITH OR WITHOUT INTERLOCK (IEC 60309-4:2006/A1:2012) |
EN 50525-2-41:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-41: Cables for general applications - Single core cables with crosslinked silicone rubber insulation |
EN 61558-1:2005/A1:2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
EN 60127-6:2014 | Miniature fuses - Part 6: Fuse-holders for miniature fuse-links |
ISO 13732-1:2006 | Ergonomics of the thermal environment — Methods for the assessment of human responses to contact with surfaces — Part 1: Hot surfaces |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
EN 60127-1:2006/A2:2015 | MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINKS |
IEC TR 60083:2015 | Plugs and socket-outlets for domestic and similar general use standardized in member countries of IEC |
ISO 9773:1998 | Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source |
EN 60738-1:2006/A1:2009 | THERMISTORS - DIRECTLY HEATED POSITIVE TEMPERATURE COEFFICIENT - PART 1: GENERIC SPECIFICATION |
CISPR 14-2:2015 RLV | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ISO/IEC Guide 14:2003 | Purchase information on goods and services intended for consumers |
IEC 60320-2-3:1998+AMD1:2004 CSV | Appliance couplers for household and similar general purposes - Part 2-3: Appliance couplers with a degree of protection higher than IPX0 |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
EN 60691:2016 | Thermal-links - Requirements and application guide |
EN 61000-4-2:2009 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
EN 50525-2-81:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding |
EN 60127-3:2015 | Miniature fuses - Part 3: Sub-miniature fuse-links |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
EN 60127-2:2014 | Miniature fuses - Part 2: Cartridge fuse-links |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
EN 82079-1:2012 | Preparation of instructions for use - Structuring, content and presentation - Part 1: General principles and detailed requirements |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60252-1 : 2011 AMD 1 2013 | AC MOTOR CAPACITORS - PART 1: GENERAL - PERFORMANCE, TESTING AND RATING - SAFETY REQUIREMENTS - GUIDANCE FOR INSTALLATION AND OPERATION (IEC 60252-1:2010/A1:2013) |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
CENELEC GUIDE 29 : 2007 | TEMPERATURES OF HOT SURFACES LIKELY TO BE TOUCHED GUIDANCE DOCUMENT FOR TECHNICAL COMMITTEES AND MANUFACTURERS |
EN 50525-2-71:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation |
EN 50525-2-31:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
EN 60112 : 2003 AMD 1 2009 | METHOD FOR THE DETERMINATION OF THE PROOF AND THE COMPARATIVE TRACKING INDICES OF SOLID INSULATING MATERIALS |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 61000-4-3 : 2006 AMD 2 2010 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST |
EN 60695-2-13:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-13: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE IGNITION TEMPERATURE (GWIT) TEST METHOD FOR MATERIALS (IEC 60695-2-13:2010/A1:2014) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
EN 50525-3-31:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke |
EN 50525-1:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 1: General requirements |
EN 62233:2008/corrigendum Aug. 2008 | MEASUREMENT METHODS FOR ELECTROMAGNETIC FIELDS OF HOUSEHOLD APPLIANCES AND SIMILAR APPARATUS WITH REGARD TO HUMAN EXPOSURE |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
EN 60127-10:2002 | Miniature fuses - Part 10: User guide for miniature fuses |
IEC 60320-2-2:1998 | Appliance couplers for household and similar general purposes - Part 2-2: Interconnection couplers for household and similar equipment |
ISO/IEC Guide 51:2014 | Safety aspects Guidelines for their inclusion in standards |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
ISO/IEC Guide 50:2014 | Safety aspects — Guidelines for child safety in standards and other specifications |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
ISO/IEC Guide 37:2012 | Instructions for use of products by consumers |
EN 60730-2-8:2002/A1:2003 | AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-8: PARTICULAR REQUIREMENTS FOR ELECTRICALLY OPERATED WIRE VALVES, INCLUDING MECHANICAL REQUIREMENTS |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
EN 41003:2008 | Particular safety requirements for equipment to be connected to telecommunication networks and/or a cable distribution system |
IEC 60730-2-8:2000+AMD1:2002+AMD2:2015 CSV | Automatic electrical controls for household and similar use - Part 2-8: Particular requirements for electrically operated watervalves, including mechanical requirements |
ISO 9772:2012 | Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
CLC/TR 50417:2016 | Safety of household and similar electrical appliances - Interpretations related to European Standards in the EN 60335 series |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
EN 22768-1:1993 | General tolerances - Part 1: Tolerances for linear and angular dimensions without individual tolerance indications (ISO 2768-1:1989) |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
EN 61032:1998 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
EN 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60906-1:2009 | IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c. |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
IEC 60034-1:2017 | Rotating electrical machines - Part 1: Rating and performance |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 60335-2-29:2016 | Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers |
EN 61000-4-34:2007/A1:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-34: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS FOR EQUIPMENT WITH MAINS CURRENT MORE THAN 16 A PER PHASE |
ISO/IEC Guide 71:2014 | Guide for addressing accessibility in standards |
IEC 60252-1:2010+AMD1:2013 CSV | AC motor capacitors - Part 1: General - Performance, testing andrating - Safety requirements - Guidance for installation and operation |
EN 60068-2-78:2013 | Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state |
EN 50525-2-12:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-12: Cables for general applications - Cables with thermoplastic PVC insulation for extensible leads |
EN 50525-3-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
EN 61058-1:2002/A2:2008 | SWITCHES FOR APPLIANCES - PART 1: GENERAL REQUIREMENTS |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-4:2012 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012) |
EN 60999-1:2000 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm² up to 35 mm² (included) |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
EN 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
EN 60335-1:2012/A13:2017 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - SAFETY - PART 1: GENERAL REQUIREMENTS (IEC 60335-1:2010, MODIFIED) |
EN 50525-2-51:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation |
EN 50525-2-72:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 60664-4:2006/corrigendum:2006 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 4: CONSIDERATION OF HIGH-FREQUENCY VOLTAGE STRESS |
EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 82079-1:2012 | Preparation of instructions for use - Structuring, content and presentation - Part 1: General principles and detailed requirements |
IEC 61770:2008+AMD1:2015 CSV | Electric appliances connected to the water mains - Avoidance ofbacksiphonage and failure of hose-sets |
EN 50366 : 2003 AMD 1 2006 | HOUSEHOLD AND SIMILAR ELECTRICAL APPLIANCES - ELECTROMAGNETIC FIELDS - METHODS FOR EVALUATION AND MEASUREMENT |
EN 60695-11-5:2017 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
EN 60127-5:2017 | Miniature fuses - Part 5: Guidelines for quality assessment of miniature fuse-links |
IEC 60695-11-5:2016 | Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance |
EN 60127-7:2016 | Miniature fuses - Part 7: Miniature fuse-links for special applications |
EN 60320-2-2:1998 | Appliance couplers for household and similar general purposes - Part 2-2: Interconnection couplers for household and similar equipment |
EN 50525-2-22:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation |
EN 60127-4:2005/A2:2013 | Miniature fuses - Part 4: Universal modular fuse-links (UMF) - Through-hole and surface mount types |
EN 60695-2-12:2010/A1:2014 | FIRE HAZARD TESTING - PART 2-12: GLOWING/HOT-WIRE BASED TEST METHODS - GLOW-WIRE FLAMMABILITY INDEX (GWFI) TEST METHOD FOR MATERIALS (IEC 60695-2-12:2010/A1:2014) |
EN 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN 50525-3-21:2011/AC:2013 | ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE |
EN 60309-2:1999/A2:2012 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012) |
EN 60664-3:2017 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
EN 61000-4-13:2002/A2:2016 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-13: TESTING AND MEASUREMENT TECHNIQUES - HARMONICS AND INTERHARMONICS INCLUDING MAINS SIGNALLING AT A.C. POWER PORT, LOW FREQUENCY IMMUNITY TESTS (IEC 61000-4-13:2002/A2:2015) |
EN 50525-2-42:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-42: Cables for general applications - Single core non-sheathed cables with crosslinked EVA insulation |
IEC 62233:2005 | Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure |
EN 60730-2-10:2007 | Automatic electrical controls for household and similar use - Part 2-10: Particular requirements for motor-starting relays |
IEC 60998-2-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
EN 50525-2-11:2011 | Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 2-11: Cables for general applications - Flexible cables with thermoplastic PVC insulation |
IEC 61000-4-34:2005+AMD1:2009 CSV | Electromagnetic compatibility (EMC) - Part 4-34: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests for equipment with mains current more than 16 A per phase |
EN 61180-1:1994 | High-voltage test techniques for low-voltage equipment - Part 1: Definitions, test and procedure requirements |
EN 60320-1:2015/AC:2016 | APPLIANCE COUPLERS FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60320-1:2015/COR1:2016) |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
EN 60730-1:2016 | Automatic electrical controls - Part 1: General requirements |
EN 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014) |
EN 60068-2-31:2008 | ENVIRONMENTAL TESTING - PART 2-31: TESTS - TEST EC: ROUGH HANDLING SHOCKS, PRIMARILY FOR EQUIPMENT-TYPE SPECIMENS |
EN 60309-1:1999/A1:2007/AC:2014 | PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012) |
EN 60320-2-3:1998/A1:2005 | APPLIANCE COUPLER FOR HOUSEHOLD AND SIMILAR GENERAL PURPOSES - PART 2-3: APPLIANCE COUPLER WITH A DEGREE OF PROTECTION HIGHER THAN IPX0 |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
EN 60990:2016 | Methods of measurement of touch current and protective conductor current |