BS EN 60439-4:2004

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

11-01-2005

Superseded date

31-03-2013

£232.00
Excluding VAT
Summarise this standard

1 General
  1.1 Scope and object
  1.2 Normative references
2 Definitions
3 Classification of ASSEMBLIES
4 Electrical characteristics of ASSEMBLIES
5 Information to be given regarding the ASSEMBLY
  5.1 Nameplates
6 Service conditions
  6.1 Normal service conditions
7 Design and construction
  7.1 Mechanical design
  7.2 Enclosure and degree of protection
8 Test specifications
  8.1 Classification of tests
  8.2 Type tests

Applies to type-tested ASSEMBLIES (TTA) intended for use on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out.

Committee
PEL/17
DevelopmentNote
Also numbered as IEC 60439-4: 1990. Supersedes 90/25373 DC & 94/214118 DC (05/2004) Supersedes 03/100155 DC. (01/2005)
DocumentType
Standard
Pages
26
PublisherName
British Standards Institution
Status
Superseded
SupersededBy
Supersedes

Applies to type-tested ASSEMBLIES (TTA) intended for use on construction sites, i.e. temporary places of work to which the public do not generally have access and where building construction, installation, repairs, alteration or demolition of property (buildings) or civil engineering (public works) or excavation or any other similar operations are carried out. These ASSEMBLIES may be transportable (semi-fixed) or mobile. This standard does not apply to ASSEMBLIES for use in the administrative centres of construction sites (offices, cloakrooms, ASSEMBLY rooms, canteens, restaurants, dormitories, toilets, etc.). The nominal primary voltage and the nominal secondary voltage of transformers incorporated in ACS shall be within the limits specified in IEC 60439-1. Requirements for electrical protection provided by equipment manufactured according to this International Standard shall comply with the requirements given in IEC 60364-7-704. NOTE: This standard may be used as a guide to partially type-tested ASSEMBLIES (PTTA) constructed according to agreement between manufacturer and user taking into account the nature of supply and/or distribution network and relevant installation requirements. The following major changes with respect to edition 1 (including amendments 1 and 2) have been incorporated: - introduction of the definition for \'rated current of ACS\'; - replacement of classification based on the rated current of ACS by classification based on the function as assigned by the manufacturer; - amended requirements for the protection of socket-outlets with reference to the more comprehensive requirements of IEC 60364-7-704; - introduction of common requirements for all types of ACS.

Standards Relationship
NBN EN 60439-4 : 2005 Identical
I.S. EN 60439-4:2004 Identical
IEC 60439-4:2004 Identical
EN 60439-4:2004 Identical
NF EN 60439-4 : 2005 Identical
DIN EN 60439-4 : 2005 Identical
UNE-EN 60439-4:2005 Identical

⚠

A newer version of this standard is available.

View Current Edition View Current Edition
£232.00