• There are no items in your cart
We noticed you’re not on the correct regional site. Switch to our AMERICAS site for the best experience.
Dismiss alert

BS EN 60601-2-54:2009+A1:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray equipment for radiography and radioscopy

Available format(s)

Hardcopy , PDF

Withdrawn date

31-05-2022

Language(s)

English

Published date

31-07-2015

Clause1 of the general standard1) applies, except as follows: 201.1.1 Scope Replacement: This International Standard applies to the basic safety and essential performance of me equipment and me systems intended to be used for projection radiography and radioscopy. IEC60601-2-43 applies to me equipment and me systems intended to be used for interventional applications and refers to applicable requirements in this particular standard. me equipment and me systems intended to be used for bone or tissue absorption densitometry, computed tomography, mammography or dental applications are excluded from the scope of this International Standard. The scope of this International Standard also excludes radiotherapy simulators. If a clause or subclause is specifically intended to be applicable to me equipment only, or to me systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to me equipment and to me systems, as relevant. NOTE Taking into account economic and social factors, the scope of this particular standard includes me equipment intended to be used for direct radioscopy. In some countries examinations performed with direct radioscopy are prohibited. 201.1.2 Object Replacement: The object of this particular standard is to establish particular basic safety and essential performance requirements for me equipment and me systems for radiography and radioscopy. 201.1.3 Collateral standards Addition: This particular standard refers to those applicable collateral standards that are listed in Clause2 of the general standard and Clause201.2 of this particular standard. IEC60601-1-2 and IEC60601-1-3 apply as modified in Clauses202 and 203 respectively. IEC60601-1-8, IEC60601-1-10, IEC60601-1-11 and IEC60601-1-12 do not apply. All other published collateral standards in the IEC60601-1 series apply as published. NOTE Operators of X-ray equipment are used to audible signals as required in this particular standard rather than to the concepts of IEC60601-1-8. Therefore IEC60601-1-8 does not apply. 201.1.4 Particular standards Replacement: In the IEC60601 series, particular standards may modify, replace or delete requirements contained in the general standard and collateral standards as appropriate for the particular me equipment under consideration, and may add other basic safety and essential performance requirements. A requirement of a particular standard takes priority over the general standard. For brevity, IEC60601-1 is referred to in this particular standard as the general standard. Collateral standards are referred to by their document number. The numbering of clauses and subclauses of this particular standard corresponds to that of the general standard with the prefix \'201\' (e.g. 201.1 in this standard addresses the content of Clause 1 of the general standard) or applicable collateral standard with the prefix \'20x\' where x is the final digit(s) of the collateral standard document number (e.g. 202.4 in this particular standard addresses the content of Clause 4 of the 60601-1-2 collateral standard, 203.4 in this particular standard addresses the content of 203.4 of the 60601-1-3 collateral standard, etc.). The changes to the text of the general standard are specified by the use of the following words: \'Replacement\' means that the clause or subclause of the general standard or applicable collateral standard is replaced completely by the text of this particular standard. \'Addition\' means that the text of this particular standard is additional to the requirements of the general standard or applicable collateral standard. \'Amendment\' means that the clause or subclause of the general standard or applicable collateral standard is amended as indicated by the text of this particular standard. Subclauses, figures or tables which are additional to those of the general standard are numbered starting from 201.101. However due to the fact that definitions in the general standard are numbered 3.1 through 3.139, additional definitions in this standard are numbered beginning from 201.3.201. Additional annexes are lettered AA, BB, etc., and additional items aa), bb), etc. Subclauses, figures or tables which are additional to those of a collateral standard are numbered starting from 20x, where \'x\' is the number of the collateral standard, e.g. 202 for IEC60601-1-2, 203 for IEC60601-1-3, etc. The term \'this standard\' is used to make reference to the general standard, any applicable collateral standards and this particular standard taken together. Where there is no corresponding clause or subclause in this particular standard, the clause or subclause of the general standard or applicable collateral standard, although possibly not relevant, applies without modification; where it is intended that any part of the general standard or applicable collateral standard, although possibly relevant, is not to be applied, a statement to that effect is given in this particular standard.

Committee
CH/62/2
DocumentType
Standard
Pages
76
PublisherName
British Standards Institution
Status
Withdrawn
SupersededBy

Standards Relationship
EN 60601-2-54:2009/A1:2015 Identical
EN 61169-38:2009 Identical
IEC 60601-2-54:2009/AMD1:2015 Identical

View more information
£314.00
Excluding VAT

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.