BS EN 60811-302:2012

Current

Current

The latest, up-to-date edition.

Electric and optical fibre cables. Test methods for non-metallic materials Electrical tests. Measurement of the d.c. resistivity at 23°C and 100°C of filling compounds

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

31-07-2012

£142.00
Excluding VAT

INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test method
5 Test report
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Provides the procedure to examine the d.c. resistivity at 23 degrees C and 100 degrees C which typically applies to filling compounds used for communication cables and optical fibre cables.

Committee
GEL/20/17
DevelopmentNote
Together with BS EN 60811-100, BS EN 60811-301, BS EN 60811-411, BS EN 60811-601, BS EN 60811-602, BS EN 60811-603, BS EN 60811-604, it supersedes BS EN 60811-5-1. Supersedes 09/30192962 DC. (08/2012)
DocumentType
Standard
Pages
12
PublisherName
British Standards Institution
Status
Current
Supersedes

This Part 302 of IEC 60811 gives the procedure to examine the d.c. resistivity at 23 °C and 100 °C which typically applies to filling compounds used for communication cables and optical fibre cables.

Standards Relationship
EN 60811-302:2012 Identical
IEC 60811-302:2012 Identical
I.S. EN 60811-302:2012 Equivalent
DIN EN 60811-302:2012-12 Equivalent
UNE-EN 60811-302:2012 Equivalent

EN 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
IEC 60811-5-1:1990+AMD1:2003 CSV Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C
IEC 60247:2004 Insulating liquids - Measurement of relative permittivity, dielectric dissipation factor (tan d) and d.c. resistivity
EN 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General
IEC 60811-100:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 100: General